Tender For Repair/Maint Of External Water Supply System At Lusal Hill At Hq Igar (East), Srikona,Repair/Maint Of Centrifugal Pump Set, Starter, Connected Panel Boards At Hq Igar (E) At Srikona,Repair/ Maintenance Work For External Electric Supply Sys
Tender Overview
Project Description
Tender for Repair/Maint Of External Water Supply System At Lusal Hill At Hq Igar (East), Srikona,Repair/Maint Of Centrifugal Pump Set, Starter, Connected Panel Boards At Hq Igar (E) At Srikona,Repair/ Maintenance Work For External Electric Supply System At Hq Igar (East) Srikona
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE ‘A’ PART - I |
| 2 | S & F roviding and fixing G.I. pipes (medium class) 80 mm dia complete with G.I. fittings including trenching and refilling etc all as specified and directed. |
| 3 | S & F roviding and fixing G.I. pipes (medium class) 65 mm dia complete with G.I. fittings including trenching and refilling etc all as specified and directed. |
| 4 | S & F roviding and fixing G.I. pipes (medium class) 50 mm dia complete with G.I. fittings including trenching and refilling etc all as specified and directed. |
| 5 | Providing and fixing 25mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, water supply including all CPVC plain & brass threaded fittings, Sockets and elboe, Tee, Union and this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 6 | Providing and fixing gun metal gate 80 mm valve with C.I. wheel of approved quality (screwed end) all as specified and directed. |
| 7 | Providing and fixing gun metal gate 63 mm valve with C.I. wheel of approved quality (screwed end) all as specified and directed. |
| 8 | Providing and fixing gun metal gate 50 mm valve with C.I. wheel of approved quality (screwed end) all as specified and directed. |
| 9 | SCHEDULE ‘A’ PART - II |
| 10 | Taking out, repair, rewinding and re-fixing of existing 30 HP electric motors for main water supply including changing of required acessories testing, commissioning etc complete as per direction of Engineer-in-charge. |
| 11 | Taking out, repair, rewinding and re-fixing of existing 15 HP electric motors for main water supply including changing of required acessories testing, commissioning etc complete as per direction of Engineer-in-charge. |
| 12 | Taking out, repair, rewinding and re-fixing of existing 7.5HP electric motors for main water supply including changing of required acessories testing, commissioning etc complete as per direction of Engineer-in-charge. |
| 13 | Material and lobour for overhauling of 30 HP pump for replacement bearing, greasing including testing, commissioning etc complete as per direction of Engineer-in-charge. |
| 14 | Material and lobour for overhauling of 40 HP pump for replacement bearing, greasing including testing, commissioning etc complete as per direction of Engineer-in-charge. |
| 15 | Supply & Fixing of PVC insulated three core sheathed submersible flat cable 10 Sqmm 3 core for submersible pumps with copper conductor 1100 V Grade Conf to IS 694 / 1990 ISI |
| 16 | SCHEDULE ‘A’ PART - III |
| 17 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 18 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 19 | Supply and installation of LT busbar panel board cubical type outdoor type made of 160mm thick M S sheet to accommodate following incoming and outgoing with Bus bar chamber suitable canopy to carry 250 AMP 410 volt copper- 01 set The including PCC platform all as specified and directed by Engineer-in-Charge |
| 20 | Supply test & commissioning LT UG cable XLPE insulated sheathed and armoured, with aluminium stranded conductor, LT 1100 Volts grade of size16 sqmm 4.0 core, complete aincluding execavation,sand cushioning, protecting covering and returning filling all as specified and as directed. |
| 21 | Supply test & commissioning LT UG cable XLPE insulated sheathed and armoured, with aluminium stranded conductor, LT 1100 Volts grade of size 25 sqmm 3.5 core, complete aincluding execavation,sand cushioning, protecting covering and returning filling all as specified and as directed. |
| 22 | Supply and fix Thermoplastic cable junction box IP 66 halogen free and weather proof for out door installation( with metric knockouts and terminals for cable entry ) of size 255x355x122 mm mm complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender