Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57222301

Tender For special Repairs Of Sewage Line In Vasanth Enclave Complex Under Ge (North) Bangalore.

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
1.46 Crore
Estimated cost
Bid Submission
08 Oct 2026
5 days left
EMD
2.21 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for special Repairs Of Sewage Line In Vasanth Enclave Complex Under Ge (North) Bangalore.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Sep-2026 CORRIGENDUM date Date 01-Oct-2026
2 30-Sep-2026 CORRIGENDUM Other 08-Oct-2026

BOQ

Name of Work:- SPL REPAIRS OF SEWAGE LINE IN VASANTH ENCLAVE COMPLEX UNDER GE (NORTH) BANGALORE.
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc. , not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in hard / dense soil etc complete all as specified and as directed.
2Excavation in trenches not exceeding 1.5m wide and depth exceeding 1.5m but not exceeding 3.0m for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and exceeding 1.5m but not exceeding 3.0m depth and getting out in hard / dense soil etc complete all as specified and as directed.
3Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick etc complete all as specified and as directed.
4Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and as directed.
5M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
6M&L for Pre-cast cement concrete block masonry, (1:3:6) Type C1 using 20 mm graded crushed stone aggregates with solid blocks, exc. 10 cm in width and setting in mortar (1:6) etc complete all as specified and as directed.
7M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete block walling surfaces finished even and smooth without using extra cement etc complete all as specified and as directed.
8M&L for Plain cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in concrete bed to 300 mm dia drain pipes including packing under and haunching in against the side of DWCP pipes after they are laid and tested complete all as specified and as directed.
9M&L for Plain cement concrete (1:3:6), type C2 using 40 mm graded crushed stone aggregate as in concrete bed to 200 mm dia drain pipes including packing under and haunching in against the side of DWCP pipes after they are laid and tested complete all as specified and as directed.
10M&L for Plain cement concrete (1:3:6), type C2 using 40 mm graded crushed stone aggregate as in concrete bed to 150 mm dia drain pipes including packing under and haunching in against the side of DWCP pipes after they are laid and tested complete all as specified and as directed.
11Supply and laying Double wall corrugated HDPE pipe , 300 mm dia laid in trenches with couplers, class SN-8 conforming to IS 16098 (part-2) complete all as specified and as directed.
12Supply and laying Double wall corrugated HDPE pipe , 200 mm dia laid in trenches with couplers, class SN-8 conforming to IS 16098 (part-2) complete all as specified and as directed.
13Supply and laying Double wall corrugated HDPE pipe , 150 mm dia laid in trenches with couplers, class SN-8 conforming to IS 16098 (part-2) complete all as specified and as directed.
14M&L plain cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in coping, benching of manholes and similar work etc complete all as specified and as directed.
15M&L for plain Cement concrete (1:2:4) type B2 using 40 mm graded crushed stone aggregate as in surface channels and drains complete all as specified and as directed.
16M&L for Precast reinforced cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in landings, cover slab (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face set in CM (1:6) complete all as specified and as directed.
17M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
18M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete (1:2:4) type B-1(using 20mm graded crushed stone aggregates) smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed.
19M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) smooth finished ,and reforming benching as required for 200 mm internal dia of pipe complete all as specified and as directed.
20M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) smooth finished ,and reforming benching as required for 300 mm internal dia of pipe complete all as specified and as directed.
21Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 110/150 mm internal dia of pipe complete all as specified and as directed.
22Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 200 mm internal dia of pipe complete all as specified and as directed.
23Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 300 mm internal dia of pipe complete all as specified and as directed.
24Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
25Demolition of cement concrete reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and as directed.
26Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
27Dismantling of Stone set paving of any description or in floors, aprons etc (Laid bedded and pointed in any cement mortar) including removing off the premises etc complete all as specified and as directed.
28M&L for 75 mm thick cement concrete (1:4:8) type D- 2 using 40mm graded crushed aggregate as in sub base of flooing etc complete all as specified and as directed
29M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set ,jointed and pointed in neat cement slurry in floors.(with grey cement and pigments) over and including 20mm screed bed or bedding layer of mortor in CM (1:6) complete all as specified and as directed.
30M&L for Cement concrete (1:2:4) type B0 using12.5 mm graded crushed stone aggregate , 25mm thick finished even as in levelling concrete for floor complete all as specified and as directed.
31M&L for cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate , 75mm thick finished even as in floor complete all as specified and as directed. Supply and fixing in repair GI pipe bracket made of 40 mm bore light grade pipe made to shape of overall length of 1.2 mtr for fixing of security light fitting including MS clamps , nuts & bolts of required size complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57222301
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.46 Crore
LAST DATE 08-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repairs Of Sewage Line In Vasanth Enclave Complex Under Ge (North) Bangalore.
Basic Detail
Tender No 86572/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 30 Sep 2026
Submission Date 08 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 1.46 Crore
Tender Fee 1000
EMD 2.21 Lakhs
Exemption Not Available
Document List
BOQ_881449.xls
c496f016-9016-4e1d-aaed-d834456b36c2.html
tender86572.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 08, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_881449.xls

html

c496f016-9016-4e1d-aaed-d834456b36c2.html

pdf

tender86572.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders