Tender For Repair And Maintenance Of Street Lights/ Flood Lights, Poles And Connected Accessories Of 39.37 Acres, Trv Area, Tech Area And Cgra Under Ge (I) (Cg) Goa
Tender Value
15 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
3 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Street Lights/ Flood Lights, Poles And Connected Accessories Of 39.37 Acres, Trv Area, Tech Area And Cgra Under Ge (I) (Cg) Goa
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in soft/ disintegrated rock for taking up/ relaying LT UG cable/ pipe complete all as specified and as directed. |
| 2 | Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard/ dense soil for taking up/ relaying LT UG cable/ pipe complete all as specified and as directed. |
| 3 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any strata complete all as specified and as directed. |
| 4 | Removing excavated rock/ soil to a distance not exceeding 50m, and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 5 | Supply and lay riddle sand in trenches for cable protection complete all as specified and as directed.Note: Punned thickness only will be measured & Paid. |
| 6 | Supply and laying un re-inforced precast concrete cable cover, class LV type-1, flat size 250mm x 150mm x 40mm in trenches over and across the cable including taking down existing complete all as specified and as directed. |
| 7 | Taking out LT UG cable of any type and size from trenches/ walls etc complete all as specified and as directed. |
| 8 | Supply, lay and testing of LT UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed of following size:- |
| 9 | 35 Sqmm x 3.5 core |
| 10 | 25 Sqmm x 4.0 core |
| 11 | 16 Sqmm x 4.0 core |
| 12 | 10 Sqmm x 2.0 core |
| 13 | Material and labour for GI pipe of size 50mm dia, light grade, laid in trenches for cable protection including taking down existing pipe complete all as specified and as directed. |
| 14 | Supply and fix in replacement of aluminium lugs of size 16/25/35 sqmm complete all as specified. |
| 15 | Taking down and relaying of existing LT UG cable size upto 50sqmm in trenches etc complete all as specified and as directed. |
| 16 | Repairs to LT street light pillar box by opening door hinges and taking out rusted portion of door including removing bends/ dents and refixing the door with new hinges, handles, making good surfaces, bolting etc and painting of LT panels by duly cleaning the surface from dust and grease and applying one coat of synthetic enamel paint by using spray gun colour of existing colour scheme as directed by the Engineer-in-Charge and lettering the LT panels with black/ white paint using stencils or marking lettering by using stickers with minimum size of letter to be of 5 CM all as specified and as directed. |
| 17 | Supply and fix MCB 6 to 16 Amps, breaking capacity 10KA, single pole including taking down the burnt MCB from the street light pole, junction boxes etc complete all as specified & directed. |
| 18 | supply and fix, test & commissioning of MCCB 63 Amps, 16KA, 4 Pole including taking down the burnt MCCBs from the LT panels/ feeder pillar boxes etc complete all as specified and as directed. |
| 19 | Material and labour for preparation surfaces of 9.00m RCC Pole by scraping with emery paper and making free from rust, dust and any foreign material and apply two coats of cement based weather proof distemper including letter writing on poles such as Pole No and source point of electric supply with black paint at minimum height of 1.2m complete all as specified and as directed. |
| 20 | Material and labour for painting of steel/ GI tubular electric poles 9.0 mtr/ 7.0 Mtr long and with two coats of aluminium paint over a coat of red oxide primer after preparation of surface approved colour and quality including letter writing on poles such as Pole No and source point of electric supply with black paint at minimum height of 1.2m complete all as specified and as directed. |
| 21 | Supply and fix 30cm wide self adhesive reflector identification strip (Red and Yalow) on LT pole as per approved colour coding, complete with surface preparation, cutting, fixing, and all necessary accessories for proper identification complete all as specified and as directed. |
| 22 | Taking down street light fitting from pole for repairing / replacement / cleaning of any wattage including removing dead insect, dust and refixing again to same location complete all as specified and as directed. Note: Replacement of accessories like driver and LA protection device will be measured and paid separately. |
| 23 | Supply and fix PVC FRP junction box of size 350 x 250 x 150mm with including 01 No, MCB SP of 6 Amp fixed on existing pole with clamp, nut & bolt connections including removing dismantling of unserviceable pole box and MCB complete all as specified and as directed. |
| 24 | Supply and fix in repair FRLS PVC insulated copper conductor of size 2 runs of 1.5 sqmm + 1 run of 1.5 sqmm as earth wire including 20mm dia non metallic PVC rigid conduit from fitting through the bracket to DB sintex box all as specified and as directed. Note: 2 run of 1.5sqmm, 1 run of 1.5 sqmm and 20mm PVC conduit will be measured as one length. |
| 25 | Supply and fix in repair LED street lights 90W, FIESTA plus PC HL new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover in the front and lens for batwing light distribution with high efficacy with separate driver compartment with IP66 protection with 10KV Built-in Surge Protection Device and giving electric connection and testing complete all as specified and as directed. Make : Orient (Model No LSFS-090-C-PC-HL) / Bajaj/ Havells. |
| 26 | Supply and fix in repair LED flood light Sigma PC 300 watt 230 V AC outdoor type high efficiency IP66 protection, with impact and corrosion resistance, front - potable with a robust pressure die-cast aluminium housing and IP rated lens cover, ensuring uniform light distribution and more than 50% energy savings compared to conventional systems complete with driver and lamp including all electric connection and testing complete all as specified and as directed.Make : Orient (Model No LFSM-300-C-PC) / Bajaj/ Havells. |
| 27 | Supply and fix in repair LED flood light Sigma PC 200 watt 230 V AC outdoor type high efficiency IP66 protection, with impact and corrosion resistance, front openable with a robust pressure die-cast aluminium housing and IP rated lens cover, ensuring uniform light distribution and more than 50% energy savings compared to conventional systems complete with driver and lamp including all electric connection and testing complete all as specified and as directed.Make : Orient (Model No LFSM-200-C-PC) / Bajaj/ Havells. |
| 28 | Supply and fix in repair LED flood light Sigma PC 120 watt 230 V AC outdoor type high efficiency IP66 protection, with impact and corrosion resistance, front openable with a robust pressure die-cast aluminium housing and IP rated lens cover, ensuring uniform light distribution and more than 50% energy savings compared to conventional systems complete with driver and lamp including all electric connection and testing complete all as specified and directed.Make : Orient (Model No LFSM-120-C-PC) / Bajaj/ Havells. |
| 29 | Supply and fix including taking down 50W smart RGB Flood Light made of Pressure Die cast aluminium along with diffused PC cover smart RGB LED flood light LFPKS-050-RGB, including all accessories suitable for installation, Input voltage - 120 - 277 V, CCT - RGB, system Lumens efficacy - 30Lm/ watt, operating temp: 10 to 45, IP -66, IK-08, 60000 burning hours, weight - 1.5kg, power factor>0.90, THD<15% ,Weight - 1.5 kg Max, LED Driver - BIS certified Outdoor rated, Internal surge -4Kv (DM/CM mode) Mode of operation - smart app. The Smart app offers options for selecting colour theme from pre set scenes, customize the colour themes as requirement or occasion and also to dim down or scales up the intensity of Smart RGB LED Flood Light complete all as specified and as directed. Make : Orient / Bajaj/ Havells. |
| 30 | Supply and fix in repair LED Driver unit for LED Street light Luminaire 70/90 W complete all as specified and as directed. |
| 31 | Supply and fix in repair LED Driver unit for LED Flood light Luminaire 120/150 W complete all as specified and as directed. |
| 32 | Supply and fix in repair LED Driver unit for LED flood light Luminaire 300 W complete all as specified and as directed. |
| 33 | Supply and fix in repair of LED PCB unit for LED Street light Luminaire 70/90 W suitable for 230V AC, 50Hz complete all as specified and as directed. |
| 34 | Supply and fix in repair of LED PCB unit for LED flood light Luminaire 120 W suitable for 230V AC, 50Hz complete all as specified and as directed. |
| 35 | Supply and fix in repair of LED PCB unit for LED flood light Luminaire 150 W suitable for 230V AC, 50Hz complete all as specified and as directed. |
| 36 | Supply and fix in repair of LED PCB unit for LED flood light Luminaire 300 W suitable for 230V AC, 50Hz complete all as specified and as directed. |
| 37 | Supply and fix 3 phase Nature time switch using infrared sensor technology based automatic street light control panel enclosed in SMC boxes with one No MCB TPN 32 Amps, with Contactor 32 Amp 3 Pole connector 4 way 32 Amps including fixing clamps, nut bolts including taking down the old damaged timer etc complete all as specified and as directed.Make : Healer or equivalent |
| 38 | Supply and fix contactor, 4 pole, 415V, 40A cap, MCX, 2 NO+2 NC utilised for heavy duty including taking down the old perished / deteriorated contactor against repairs complete all as specified and as directed. |
| 39 | Supply and fix in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4.0 core XLPE armoured aluminium conductor cable of size 16 sqmm complete all as specified and as directed. |
| 40 | Supply and fix in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4.0 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and as directed. |
| 41 | Material and labour for Plain Cement concrete 1:2:4, type B1using 20mm graded stone aggregate for pole coping including necessary formwork etc complete all as specified and as directed. |
| 42 | Supply and fix in repairs single arm street light pole bracket made out of GI pipe 40mm dia, light grade, not less than 0.9M length bent to shape for fixing of street light fitting and D type clamp MS flat iron 25 x 4mm with nut, bolt & washers including two coats of aluminium paint over a coat of red oxide primer approved colour and quality etc complete all as specified and as directed. |
| 43 | Supply and fixing in repairs single arm street light pole top mounted, both side bracket type with two opposite direction arms from top (dual mounting arrangement) or as per site requirement made out of GI pipe 40mm dia light grade, not less than 0.9M length for fixing of street light fitting and two coats of aluminium paint over a coat of red oxide primer approved colour and quality etc complete all as specified and as directed. |
| 44 | Material and labour for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 m below ground level and connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI wire protection (upto 7.5m long) & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.Note: On completion of the work/job the Contractor is to perform earth resistance tests for each earthing job in the presence of the Engineer-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Department till the results are satisfactory. |
| 45 | Supply and fix MCCB spreader terminal 4 pole all as specified and as directed. Make : L & T/ Havells/ Legrand Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysSep 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender