Tender For Repair Of Munsyari Water Supply Scheme ( Hokara, Rumidor& Didihat)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Sep 2026
8 days left
EMD
11.60 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Almora → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Of Munsyari Water Supply Scheme ( Hokara, Rumidor& Didihat)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Aug-2026 | Technical Bid | Technical Bid | 24-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Rates of Repair of Munsyari Water Supply Scheme ( Hokara, Rumidor & Didihat) |
| 2 | Pre Sedimentation WorkDemolition and Earth Work |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge in ordinary rock. |
| 5 | Construction of Pre Treatment Unit |
| 6 | Providing and laying in position machine batched and machine mixed Design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 7 | Extra for providing richer mixes (M30) at all floor levels. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Shuttering for RCC workFoundations, footings, bases of columns, etc. for mass concrete |
| 10 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 12 | Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc. |
| 13 | Stairs, (excluding landings) except spiral-staircases |
| 14 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 15 | Protection and Related Work |
| 16 | Earth work in excavation in foundation for retaining wall's, breast wall's & CC WTP Road 2.5m Wide with side drain And other structures protection works. |
| 17 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications. Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix 1:2:4 (Hand mixed). |
| 18 | Providing and laying in position machine batched and machine mixed Design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 19 | Painting and Finishing Work |
| 20 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 21 | Steel & Fabrication Work for Chain Pulley and Arrangement |
| 22 | Steel work welded built of section /framed works including cutting fixing in position applying a priming code of approved steel primer using steel its as required in gratings, frames, guard bar, ladder, railing gates and similar works.Section of 300 mm ISMB Beam &Rotating Bridge. |
| 23 | Chemical House |
| 24 | Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas exceeding 30cm in depth, 1.50m in width as well as 10 sqm on plan) including disposal of excavated earth within a lead of 50 m & lift up to 1.5 mtr. Disposal earth to be levelled and neatly dressed. Excavation in all kind of soils. |
| 25 | Earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 mtr in width or 10 sqm on plan) including dressing of sides and ramming of bottom, lift up to 1.5 mtr incl. getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in ordinary rock. |
| 26 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 27 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering and shuttering finishing and reinforce- ment all work up to plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 grad aggregate 20 mm nominal size) |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landing, balconies, shelves, Chajjas, lintels, bands, plain window sills, stair cases and spiral stair cases up to floor five level excluding the cost of centering and shuttering finishing and reinforcement -all work up to plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 grade aggregate 20 mm nominal size) |
| 29 | Extra for providing richer mixes (M30) at all floor levels. |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 31 | Centering and shuttering including strutting, roping etc. and removal of form for edges of slabs and breaks in floors and walls under 20 cm wide. Foundations, footings, Plingth beam of columns, etc. for mass concrete |
| 32 | Columns |
| 33 | Beams |
| 34 | Provide Ist class brick in 1:6 cement and sand mortar.In foundation up to plinth |
| 35 | in superstructure |
| 36 | 40mm thick DPC in 1:2:4 with cement, sand and 20mm gauge stone ballast mortar. |
| 37 | Steel work welded built of section /framed works including cutting fixing in position applying a priming code of approved steel primer using steel its as required in gratings, frames, guard bar, ladder, railing gates and similar works. |
| 38 | Earth filling into plinth including it's excavation. |
| 39 | Provide 25mm thick PCC flooring in 1:2:4 with cement, sand and 20mm gauge stone ballast mortar. |
| 40 | Provide 5mm thick glass strips on flooring 20mm deep. |
| 41 | Provide 15 mm thick plaster in 1:4 cement and sand mortar (Rough &.plain both sides) |
| 42 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile. |
| 43 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content. |
| 44 | Provide acrylic smooth exterior paint (two or more coats) to give an even shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm). |
| 45 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture. |
| 46 | Supply and fixing of 4mm thick plane glass panes on window's including supply of nails and putty etc all complete. |
| 47 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 48 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per litre . |
| 49 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 50 | Foundation of Pumps |
| 51 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering and shuttering finishing and reinforcement -all work up to plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 grad aggregate 20 mm nominal size) in foundation & footings. |
| 52 | Centering and shuttering including strutting, roping etc. and removal of form . |
| 53 | Reinforcement in RCC work including straightening, cutting, bending, placing in position and binding, using Thermo-Mechanically Treated bars all complete. |
| 54 | Piping and Valves |
| 55 | Supply & Laying - Jointing of following Sizes D.I/D.F K-7 S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment,making the joints with approved EPDM quailty of rubber gaskets including cost of all jointing materials and testing etc. complete but excluding excavation and backfilling of trenches upto ground level. 100 mm dia D.I/D.F K-7 Series pipe. |
| 56 | 250 mm dia D.I/D.F K-7 Series pipe. |
| 57 | 300 mm dia D.I/D.F K-7 Series pipe. |
| 58 | 350 mm dia D.I/D.F K-7 Series pipe. |
| 59 | 400 mm dia D.I/D.F K-7 Series pipe. |
| 60 | 700 mm dia D.I/D.F K-7 Series pipe. |
| 61 | Making Flanged Joints between D.I. D/F Pipes and D.I. D/F Specials, including cost of jointing materials like Flanges , Nut & bolts, Packing, required degree bend of standard quality and make with testing of joints.100 mm dia D.I/D.F K-7 Series pipe. |
| 62 | 250 mm dia D.I/D.F K-7 Series pipe. |
| 63 | 300 mm dia D.I/D.F K-7 Series pipe. |
| 64 | 350 mm dia D.I/D.F K-7 Series pipe. |
| 65 | 400 mm dia D.I/D.F K-7 Series pipe. |
| 66 | 700 mm dia D.I/D.F K-7 Series pipe. |
| 67 | Providing & Fixing of following Sizes DI/DF Non Return Valve Confirming to IS: 14846-2000 in position including supply of all material, labourer, T&P etc complete as per requirement of site.100 mm dia D.I/D.F Non Return Valve . |
| 68 | 250 mm dia D.I/D.F Non Return Valve . |
| 69 | 300 mm dia D.I/D.F Non Return Valve . |
| 70 | 350 mm dia D.I/D.F Non Return Valve . |
| 71 | 400 mm dia D.I/D.F Non Return Valve . |
| 72 | 700 mm dia D.I/D.F Non Return Valve . |
| 73 | Providing & Fixing of following Sizes DI/DF Sluice Valves Confirming to IS: 14846-2000 in position including supply of all material, labourer, T&P etc complete as per requirement of site.100 mm dia D.I/D.F Sluice Valve. |
| 74 | 250 mm dia D.I/D.F Sluice Valve. |
| 75 | 300 mm dia D.I/D.F Sluice Valve. |
| 76 | 350 mm dia D.I/D.F Sluice Valve. |
| 77 | 400 mm dia D.I/D.F Sluice Valve. |
| 78 | 700 mm dia D.I/D.F Sluice Valve. |
| 79 | Designing, Supplying, Installing, Commissioning & testing of following Sizes Flow Control Valve with level control / Pressure reducing valve/ Alttitude Valve for inlet/ outlet with flow controlling, pressure controlling & monitoring on web and to the pipeline feeding to ESR/MBR/GSR with cable, PLC SCADA etc complete.250 mm dia D.I/D.F Sluice Valve. |
| 80 | 300 mm dia D.I/D.F Sluice Valve. |
| 81 | 350 mm dia D.I/D.F Sluice Valve. |
| 82 | 400 mm dia D.I/D.F Sluice Valve. |
| 83 | SITC of full bore Electromagnetic meter of following sizes complete as per specification including transportation to site, storage, safety, installation, testing, commissioning, making connections with existing pipe line, including excavation at site, cuts in the existing pipe system, dewatering and reinstating the same after completion of installation as per specification and drawings including all taxes. Accuracy of meter + 0.3% of measured value, Flange connection as per AWWA & IS, Liner: Hard Rubber, Fully welded sensor housing complying to IP 68 standard, Electrodes SS 316, Sensor housing SS 304, Cable gland 1/2\\" NPT, Sensor housing fully welded SS 304 housing with protective Polyurethane paint, Flow Transmitter/ Converter : Microprocessor based, modular design display 2 line back lit LCD for indication of actual flow rate, forward, reverse, sumtotalizer, Perfection category : IP 65Output : One current output (4-20 mA) one scalable pulse output.250 mm dia EMF . |
| 84 | 300 mm dia EMF. |
| 85 | 350 mm dia EMF . |
| 86 | 400 mm dia EMF . |
| 87 | 700 mm dia EMF . |
| 88 | Providing of all materials,Carting from site store to site of work, Laying & Jointing of 50 mm G.I heavy duty pipes confirming to IS: 1239 (PART-1) including supply of all jointing materials like specials, white lead, hemp and oil etc in trenches with itscutting, threading and testing of pipe line etc complete. |
| 89 | Providing and laying S:S cable duct of size given below for laying electric cable including form work for centering M.S. bar reinforcement, necessary excavation bolder filling, , compacting, curing, plastering , including providing and fixing 35 X 35 X 5mm M.S. angles, S:S cover of Adequate length with 100 mm overlap on either walls etc complete and providing S:S covers. Cable Duct 2 tier - 750 W x 750 D. |
| 90 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc,of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 91 | E&M Work |
| 92 | Providing, erecting and giving test and trial of Foot Mounted TEFC motor 1500 RPM, squirrel cage induction motor, conforming to IS 12615:2011 of efficiency class IE3 premium having continuous rating suitable for operation at 415 Volts +/-10%, 3 Phase, 50 Hz +/-3% with \\"F\\" class insulation Motor of 3.7 KW. |
| 93 | Providing, erecting and giving test and trial of Foot Mounted TEFC motor 1500 RPM, squirrel cage induction motor, conforming to IS 12615:2011 of efficiency class IE3 premium having continuous rating suitable for operation at 415 Volts +/-10%, 3 Phase, 50 Hz +/-3% with \\"F\\" class insulation Motor of 2.2 KW. |
| 94 | SITC of energy efficient S1 duty Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as per following duties including supply of star delta starter ( having ampere and voltmeter incoprated with selector switch ,cable upto distribution main and all jointing material such as lugs complete labour T&P etc complete as required at site.Pump having Discharge 4200 lpm at head of 20 meter. |
| 95 | Pump having Discharge 6500 lpm at head of 30 meter. |
| 96 | Pump having Discharge 8500 lpm at head of 25 meter. |
| 97 | Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. Pressure gauge (100 mm dia) |
| 98 | LT Control Panel INCOMMING FEEDER: 01 Nos. comprising of following accessories.Suitable Rated MCCB offers 50 ka short circuit breaking capacity ACB/L&T/BCH or equivalent make -01 No for Incommer of the LT supply.0-500 Volt, voltmeter analoge type with selector switch-01 No.Suitable Rated Ammeter analoge type with CT\\" with selector switch- 01 Nos. Frequency meter- 01 No.KWH meter-01 No.Phase indication lamp-01 set.Power factor meter-01 No.Copper Bus bar of Suitable size.OUT GOING FEEDER: 18 Nos. comprising of following accessories.Suitable Rated MCCB offers 50 ka short circuit breaking capacity ABB/L&T/BCH/HAVELLS/SCHEINDER or equivalent make -01 No for Outgoing of LT supply.0-500 Volt, voltmeter analoge type with selector switch-01 No.Suitable Rated Ammeter analoge type with CT\\" with selector switch- 01 Nos. Indication of motor on Distribution panel-04 No.LT power capacitors of suitable KVAR rating - 08 Nos.Copper Bus bar of Suitable size. |
| 99 | Power Wiring and Earthing |
| 100 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core as per manufacturer specification copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU. |
| 101 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core as per manufacturer specification copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 102 | Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 Pairs x1 sq.mm. as per IS 694 copper Shielded, twisted, multi stranded armoured cable on wall in GI tray or on ground. Signal Cable. |
| 103 | Complete double earthing material for entire installation such as earth strips, earth plates, coal salt etc as required as per IE rules. |
| 104 | SCADA System |
| 105 | Designing, Supplying, Installing, commissioning & testing of Ultrasonic level transmitter CE marked with following technical parameters Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDRange- 0-5 mtr.Accuracy - +/- 0.25% of Full Scale or betterEnclosure- IP 68Mounting - On PLC panel |
| 106 | Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68 |
| 107 | Designing, Supplying, Installing, commissioning & testing of Power Analyser interfacing to PLC Panel with modbus communicatuion port , as per IEC 62053 and in the prescribed format including mounting arrangement. |
| 108 | PLC panel for Raw water pump House with Six PumpsDesign, manufacture, supply, installation, testing andcommissioning of indoor type PLC panel of size approx. 1000 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color. The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration. The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at Raw water Pumphouse PLC shall have Ethernet port & protocal for Modbus TCP communication with following IO.DI –32 numDO – 32 numAI –24 numAO – 8 num.7 inch color TFT HMI complete with programming shall be provided to interact with PLC The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of pump house.MCB 10A DP – 1 numMCB 4A DP – 4 num24 VDC Power Supply 10A – 1num Push Buttons – 7 numSelector Switch - 2 numControl Contactor – 6 num Annunciator with 6 WindowsNO to NC TypeElectronic Hooter – 1 numControl Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch –1 num Control Indication Lamp –5 numWiring + TB etc – 1 lotHardware – 1 lot |
| 109 | Design, Supply, Installation, Testing of pH analyser as per IUPAC( International Union for Pure & Applied Chemistry)at A.F. and Interfacing with PLC panel including mounting arrangement.Range : 0 ‐14 ,pH Accuracy : Better than 0.1% of full scale ,Supply Voltage : 24V dc,Output : 4‐20 mA /HARTAs per IEC 61000-6-2 & IEC 61000-6-3 |
| 110 | Design, Supply, Installation, commissioning, testing of Turbidity Anayser as per ISO 7027 scattering light method at A.F. and Interfacing with PLC panel. Turbidity analyser shall comprises of 3 components i.e. sensors,signal distributor and transmitter with indicator. with 2 Outputs, 1 to PLC & anather to Local Display with mounting arrangement.Overall Range : 0 ‐ 2000 NTUAccuracy : +/‐ 0.02 NTUSupply Voltage : 230 V acOutput : 4‐20 mA /HART |
| 111 | Design, manufacture, supply, installation, testing and commissioning of SCADA System for WTP Plant, Sand Filter beds & pump house. Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares. PC configuration shall not be less than Intel i7 14th Gen CPU, 16 GB Ram, 1 TB SDD, 500 GB HDD, DVD RW, Rs232 & Rs485 port, 2 RJ45 ports,wireless Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Security software for 3 years license.SCADA Software of reputed company with developer & runtime license with minimum 512 number of Tags with following features & functions.1. Supervise real-time data in the form of graphical presentation.2. Control WTP processes locally or through Remote locations.3. Dynamic process Graphic, It should resemble the process mimic. SCADA should have good library of symbols so that develop the mimic as per required. When operator sees the screen he should know what’s going in plant.4. Alarm summery & Alarm history, SCADA system must be able to detect, display, and log alarms and events. When there are problems the SCADA system must notify the operators to take corrective action.5. Acquire real-time data as well as logs data with Real time trend & Historical time trend.6. Web Connectivity, Real-time displays can be accessed on remotely attached PCs and notebooks using internet.SCADA Programming shall be done so as operator can visualize and control complete WTP operation from operator desk. All important alarms & events shall be logged. All the data from field instruments & equipments shall be logged. There shall be provision to take reports in required formats of real time & historical data, events & alarms. There shall be provision of broadcasting messages, emails of reporting information. There shall be provision of access security.An Industrial grade Din rail mounting ethernet switch with 5 ports shall be provided. An Industrial grade modem with 4G/5G GSM connectivity shall be provided. |
| 112 | Secondary work station PC. Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares. PC configuration shall not be less than Intel i75 14th Gen CPU, 16 GB Ram, !TB SDD, 500 GB HDD, DVD RW, Rs232 & Rs485 port, 2 RJ45 ports, wireless Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Security software for 3 years license. |
| 113 | Providing, installing & commissioning with satisfactory test & trial Chlorine/ sodium Hypochloride dosing portable water chlorination system ( Automatic ) having chlorine as a sodium Hypochloride with following components, Capacity 10gm/hr. to 250gm/hr. |
| 114 | Alum & Lime Dosing Pumps Dosing Skid |
| 115 | Supply of following tools required for maintenace of pumping plants.(i) DE spanner set 12 Pieces: 1 Set.(ii) Ring spanner set 12 Pieces: 1 Set.(iii) Screw driver 200/250/300 mm size:3 Nos.(iv) Insulated Plier 200/250 mm size: 2 No.(v) Hammer 2 Kg: 1 No.(vi) Water pump plier 250 mm size: 1 No.(vii) Line tester: 1 No.(viii) Pipe wrench 300/350 mm size- 2 Nos.(ix) Screw wrench 300 mm size- 1 No.(x) Bearing Puller-1 No.(xi) Crimpling tool (Hydraulic type)-1 No.(xii) Digital Tong tester - 1 No. |
| 116 | Fire Extinguisher (6 Kg) CO2 (ABC Type) of 'C' class. |
| 117 | Supply of rubber resistance sheet size 1m x 2m x 0.015m. |
| 118 | Internal and external electrification of Pump house including internal wiring , piping , switches, socket,plugs,exhaust fan outside light, led light inside the pump house with all material labour T&P etc complete. |
| 119 | Providing, erecting Travelling Trolley of capacity as below with 6 m lift, tested to 50% over load. 1 Ton HOT Monorail to lift Chemical |
| 120 | Providing, erecting Travelling Trolley of capacity as below with 6 m lift, tested to 50% over load. 2 Ton HOT Monorail to lift pump |
| 121 | Cost of Routine and Preventive maintenance it also includes calibiration and other expense such as licence , annual cost of antivirus , scada complete. |
| 122 | Environment CompliancesPre-Construction |
| 123 | Ambient Air Quality Monitoring |
| 124 | Surface Water Quality |
| 125 | Potable Water Quality |
| 126 | Noise Quality |
| 127 | During Construction |
| 128 | Ambient Air Quality Monitoring |
| 129 | Surface Water Quality |
| 130 | Potable Water Quality |
| 131 | Noise Quality |
| 132 | Environmental Management / OHS Occupational Health Safety Training |
| 133 | Labour Compliances |
| 134 | Provision of Mobile Toilets at Work Site including maintenance till Construction Period(i) Supply and commissioning of mobile toilets on wheel/ prefab toilet (2 units each Toilet and Bathroom) with proper water supply and drainage system, electric supply and safe access at work site locations. |
| 135 | (ii) Maintenance: Daily cleaning twice a day by engaging one permanent helper. |
| 136 | IEC and Social Safeguards Trainings |
| 137 | SMP Training at site (1 day) |
| 138 | Labour Laws Training at site (1 day) |
| 139 | Training on sensitization on Gender issues including SEA/SH Provisions |
| 140 | GRC meeting / stakeholder meeting |
| 141 | Community Meetings/Public Consultations & Community Health and Safety Training |
| 142 | Awareness Training for HIV/AIDS and other STDs. |
| 143 | Display boards & caution boards at site . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Sep 24, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender