Tender For Maintenance Of External Ht E/S Network In Akhnoor Mil Stn Under Ge (S) Akhnoor
Tender Value
35 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
14 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance Of External Ht E/S Network In Akhnoor Mil Stn Under Ge (S) Akhnoor
BOQ
| Sl. No. | Item Description |
| 1 | Complete overhauling and servicing of 33 KV indoor type VCB including disassembly of operating mechanism parts, spring charging motor and mechanism well cleaning with petrol and CRC-226, replacing unserviceable parts/accessories oiling and greasing of moving parts, dismantling checking and well cleaning of pole insulator, checking of vacuum interrupters, well cleaning mechanism linkages drive insulators and fiber reinforced plastic frame around the vacuum interrupters including routine and periodical test as specified and directed by Engineer-in-Charge.(Note : Supply only spares will be measured and paid separately) |
| 2 | Supply only the following spares of VCBs and connected control and switchgear accessories. |
| 3 | Supply only spring charging motor with gear and connector for VCB of voltage 30 Volts DC or as required at site compatible with OD VCB |
| 4 | Supply only Closing and tripping coil for SF6/VCB as per site requirements complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply only Auxillary switch for 33/11 VCB as per site requirements. |
| 6 | Supply only Limit switch for 33 KV VCB as per site requirements complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply only Hooter suitable for 33/11 KV breaker complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply only T&C switch with locking arrangement.suitable for 33 KV breaker complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply only Remote selector switch suitable for 33 KV breaker complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply only LED Indicating lamps of desired colour dual input type complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply only Vaccum Interrupting unit (bottle type) suitable for SF 6 breaker complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply only Control Cable 8 core armoured control 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unit complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply only Control cable 4 core armoured control cable 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unit complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and fixing CT outdoor type oil immersed ratio 75-50/5+5A (three core type) Class I & 5P10 VA Burden-15 with first oil filled suitable for 33 KV power supply by providing suitable size of nuts, bolts on existing structure complete including taking out old unserviceable CTs. complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply, fixing, commissioning and testing of 33000 x 110 volts / √3 outdoor type single pole potential transformer and self air cooled type having 200 VA burden suitable for metering of equipment installed on existing structure with suitable fixing arrangement including dismantling of old PTs complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply and fixing in replacement of 33 KV rotating , horizontal type, isolator switch 400 Amp complete with all fixing arrangements after disconnecting all electric connections, and keeping aside for offering credits complete all as specified and directed |
| 17 | M&L for scrapping laid out aggregate of any size and removing from site and cleaning of dirt and vegetation from site and relaying of the same in switchyards complete all as specified and directed by Engineer-in-Charge. |
| 18 | Preparation of iron fencing complete 33 KV grid including gates of iron gates by scrapping of rusted materials, and painting with two coats of aluminium paint of approved make and colour complete all as specified and directed. |
| 19 | Preparation of old cement based painted surfaces by scrapping of deposited materials, and painting with two coats of cement based paint of approved make and colour complete all as specified and directed. |
| 20 | M&L for painting of HT 33 KV HT grid steel structure including all MS channel isolators, CTs, PTs and MOCBs, VCBs, bus bar and other steel structure with synthetic enamelled aluminium paint on structure abd other colour code for equipment after proper surface preparation all as specified and directed. |
| 21 | M&L for Jumpers works in PTs, CTs, MOCBs, isolator, DO fuse by using parallel grove clamp, Tee clamp Tee clamps other connectors required by using ACSR conductor any sizess (Dog/Mouse) including dismantling old conductor and clamp all as specified and as directed. |
| 22 | M&L for repalcement of PG clamps, parallel grove clamps, tee clamps, GI nuts bolts of required size other connectors for connecting ACSR conductor for jumpering all as specified and as directed. |
| 23 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to DB/Panel by using GI strip of 25x4 mm sleeved using red colour PVC sleeving as earthing lead soldering/rivetted to earth plate at one end and connected to existing structure by means of nut, bolts etc complete with PCC pit (1:3:6) type PCC cover with handle, funnel with watering pipe wire mess GI protection pipe for earthing lead complete all as specified and as directed. |
| 24 | Supply and fixing Danger notice plate of 1.6 mm thick MS sheet,25X20CM Size vitreous enamelled white with letters, figures and conventional skull and bones with MS clamp, bolts and nuts of approved size for HT 33 KV/ 11 KV mark complete all as specified and directed. |
| 25 | M & L for Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9, Incl taking down old pole and remove from site complete all as directed. |
| 26 | Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles etc, complete all as specified and as directed by Engineer-In-Charge. |
| 27 | Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge. |
| 28 | Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 95 Sq mm, 3 core complete all as specified and directed. |
| 29 | Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 120 Sq mm, 3 core complete all as specified and directed. |
| 30 | Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 240 Sq mm, 3 core complete all as specified and directed. |
| 31 | M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soil not exc 1.5 Mtr wide and not exc. 1.5 m in depth for foundation and getting out complete all as specified and as directed. |
| 32 | M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soil not exc 3.0 Mtr wide and not exc. 3.0 m in depth for foundation and getting out complete all as specified and as directed. |
| 33 | M & L for returning filling in including spreading, levelling, watering and ramming in layers not exceeding 25 cm thick with earth obtained from excavation all as specified and as directed. |
| 34 | M & L for removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and as directed. |
| 35 | M & L for unwashed sand cushioning below and around cable in trenches with river sand all as specified and as directed by Engr-in-Charge. |
| 36 | Supplying and laying un-reinforced precast concrete cable cover HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as directed by Engr-in-Charge |
| 37 | S & F 80mm bores of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable all as specified and as directed by Engr-in-Charge. |
| 38 | S & F 100 mm bores of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable all as specified and as directed by Engr-in-Charge. |
| 39 | Supply and fixed cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 240 sqmm to 300 sqmm complete all as specified and directed. |
| 40 | Supply and fixed cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 240 sqmm to 300 sqmm complete all as specified and directed. |
| 41 | Supply and fixed cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. |
| 42 | Description all as per item No 30 above but 120 sqmm to 185 sqmm |
| 43 | Supply and fixed cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm Complete all as specicified and directed. |
| 44 | Description all as per item No 32 above but 120 sqmm to 185 sqmm |
| 45 | Supply and fixed cable straight through jointing kit for 11 KV grade cable for out door heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. |
| 46 | Supply insatallation, testing and commissioing of maintenance free earthing based on 300mm long GI earthing Electrode (Met -Chem) 80mm outer dia and inner rod with 10mm thickness 3000mm long duly filled with ITPC-EECP15 fixed with nuts an bolts incl excavation/ earth work in any strata & PCC chamber with CI Frame and cover (Earth pit not less than 2.25 mtrs below ground level). The electrode is surrounded by chemical (ITPC-EECP15) a mixture of sulphate, silica, Iron Oxide etc, magnesium oxide, sodium oxide, zinc oxide etc. Each Earth electrode should have resistance <2 Ohm by using earth electrode is used as per the site requirements. Chemicals compound powder to be provided minimum 50Kg per site. The inspection joint provide for earthing reference incl the man hole cover with locking facility be provided. |
| 47 | S&F Copper strip of size 20x3 mm as in earth continiuty conductor fixed to wall on batten or recess or cases or buried in ground or any other situation for loop earthing as required at site al as specified and directed by engr in charge |
| 48 | Disconnecting electrical connections from HT 33/11 KV transformer of any descriptions by opening of earth & control connections of any type, sealing of oil leakage, replacement of unserviceable parts and filtration of oil, cleaning the transformer, including making all HT connections, control cable connection, earth connection etc including testing the transformer after necessary repairs, complete all as specified and as directed by Engineer-In-Charge. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items |
| 49 | Supply and fixing in replacement of primary coil of transformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge.Note: Primary coil shall have same number of turns of winding wire and with matching to manufacturer design. |
| 50 | Supply and fixing in replacement of secondary coil of transformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge.Note: Secondary coil shall have same number of turns of winding wire and with matching to manufacturer design. |
| 51 | Disconnecting electrical connections from HT and LT sides of old unserviceable/ damaged/ burnt step down transformers of any descriptions, capacity upto 400 KVA, any type and taking down from the platforms or mounted on exisiting position (four poles/ two pole structure) by hydraulic cranes of suitable capacity and transporting by truck/ lorry to the workshop, opening top cover, draining out the transformer oil in clean barrels, cleaning of sludge from oil tank and conservator tank, cleaning and polishing of tapping contact point, opening carefully copper wire/ strip wound LT coils and rewinding the same after providing new necessary insulating packing material by using the same old strip/ wire, refitting top cover with replacement of studs, nuts, bolts, washers and gasket after repairs/ replacement of unserviceable parts and cleaning the transformer and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, placing in original position on four pole/ two pole structure/ platform at site and making all HT/LT connections including testing the transformer after necessary repairs, complete all as specified and as directed by Engineer-In-Charge. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ. |
| 52 | Replacement of old unserviceable/ damaged 33 KV HT bushing assembly with new HT bushing assembly (Set of three) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, any capacity complete all as specified and as directed by Engineer-In-Charge. |
| 53 | Replacement of old unserviceable/ damaged 11 KV HT bushing assembly with new HT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, of any capacity, complete all as specified and as directed by Engineer-In-Charge. |
| 54 | Replacement of old unserviceable/ damaged cork sheet gasket with new cork sheet gasket, suitable for transformer of any capacity, complete all as specified and as directed by Engineer-In-Charge. Please Enable Macros to View BoQ information |
| 55 | Replacement of old unserviceable/ damaged cork sheet gasket with new cork sheet gasket, suitable for transformer of any capacity, complete all as specified and as directed by Engineer-In-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender