Tender For Provision Of Or Living Accn At Baramulla Under Ge 969 Ews (Tender Id: 2026_Mes_ 786504 _1)
Tender Value
10.72 Crore
Estimated cost
Bid Submission
30 Sep 2026
28 days left
EMD
8.61 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Or Living Accn At Baramulla Under Ge 969 Ews (Tender Id: 2026_Mes_ 786504 _1)
BOQ
| Sl. No. | Item Description |
| 1 | Note: (i) Please refer Schedule 'A' Notes given in tender documents.(ii) The Schedule 'A' Part-XV is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col. 5 signifies this fact only. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I. |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-II. |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-III. |
| 6 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-IV. |
| 7 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-V. |
| 8 | Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-VI. |
| 9 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-VII. |
| 10 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII. |
| 11 | Lump sum price worked out by the contractor for CENTRAL HEATING SYSTEM WORKS carried forward from Pre-Priced Schedule 'A' Part-IX. |
| 12 | Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-X. |
| 13 | Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLING WORKS carried forward from Pre-Priced Schedule 'A' Part-XI. |
| 14 | Lump sum price worked out by the contractor for SHED FOR DG SET WORKS carried forward from Pre-Priced Schedule 'A' Part-XII. |
| 15 | Lump sum price worked out by the contractor for SPECIAL ITEM OF B/R WORKS carried forward from Pre-Priced Schedule 'A' Part-XIII. |
| 16 | Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-XIV. |
| 17 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE 'A' PART-XV)(A) INTERNAL WATER SUPPLY WORKS |
| 18 | S&F of two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. (flow rate - 8 LPM), ISI Marked, complete all as specified and directed. |
| 19 | S&F Pillar Cock (Low-flow) 16 mm dia. (flow rate - 8 LPM) Chromium plated, ISI Marked complete all as specified and directed. |
| 20 | Supply & fixing of Health faucet (ABS Body) (Low-flow) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook (flow Rate - 10 LPM) ISI Marked, complete in all respect as specified. |
| 21 | S & F of Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves, ISI Marked, complete all as specified and directed. |
| 22 | S &F of 15 mm bore PUSH Cock ( Low-flow)for urinal for iron pipe and fixed.( PRS-CHR-073) (flow rate -3.8 LPF), ISI Marked, complete all as specified and directed. |
| 23 | S & F of Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges, ISI Marked, complete all as specified and directed. |
| 24 | (B) INTERNAL ELECTRIFICATION WORKS |
| 25 | S & F of modular type 1 module RJ-11 telephone scoket with shutter complete all as specified and directed. |
| 26 | Supply and fixing load line distribution board TPN vertical, 8 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories complete all as specified and as directed.Note: Outgoing MCBs shall be measured and paid separately. |
| 27 | Supply and fixing load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed.Note: Outgoing MCBs shall be measured and paid separately. |
| 28 | S & F of 6W LED mirror light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. |
| 29 | Supply and fixing of 12W Surface down light fitting with 220 V AC and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 30 | Supply and fixing of 6W Study led light fitting with 220 V AC and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 31 | S & F of 40 Watt low bay light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, wall mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed. |
| 32 | M & L of 1.1 kV grade, conductor, XLPE insulated armoured cable 3 Core, 1.5 mm2 XLPE Insulated Armoured, conforming to IS 7098 (Part 1): 1988, having stranded Aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, complete as required.(For internal and external electric- 400+100RM) |
| 33 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-1 (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. Make: Schneider, Siemens, ABB |
| 34 | The PANEL shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 100A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]63A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos[ii]32A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos[iii]10A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 1P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos[vi] LED phase indicators (Red, Yellow, Blue)- 07 Set |
| 35 | (C) EXTERNAL ELECTRIFICATION WORKS |
| 36 | Supply and fix street light junction box mistral IP 65 thermoplastic enclousers with transperent door 4mm thick in 4 modulus in single row of size 210 x 155 x 92 with SP 0.5 Amp MCB and including clamp of size 20x3 mm thick of flate iron with bolt, nut etc required in mounting in steel toolbar pole 8.5 mtr long complete all as specified and directed. |
| 37 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type MLTP PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-chargeThe PANEL shall comprise of the following: |
| 38 | [A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 200A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]160A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]125A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos ( FOR CHS PANEL , 1 NOS SPARE)[ii]63A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos ( 1 NOS FOR PDB 1(OR LIVING ACCN)) |
| 39 | [iii]40A, 415 V, Ics = 100% Icu = 16kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos ( 1 NOS FOR APFC + 1 NOS SPARE)[iv]20A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos ( FOR PDB 3 (CHS BUILDING)[v]16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos ( FOR PDB 2 (DG SHED)[vi] LED phase indicators (Red, Yellow, Blue)- 07 Set |
| 40 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type DG PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-chargeThe PANEL shall comprise of the following: |
| 41 | [A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 200A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]125A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i] 100A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos (1-CHS PANEL) |
| 42 | [ii] 32A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos ( FOR ACDB (OR LIVING ACCN)[iii] 20A,230 V, Ics = 100% Icu = 10 kA, 50 Hz 1P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos ( 3 NOS- HOT WATER SUPPLY)[iv] 20A,415 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2, having trip unit, front indication LEDs (ready, overload and pre-alarm & overload)- 01Nos ( FOR STREET LIGHT)[vi] LED phase indicators (Red, Yellow, Blue)- 06 Set |
| 43 | Supply, installation, testing and commissioning of free-standing indoor, modular, extendable, 25 kVAr APFC Panel having maintenance friendly semi compartmentalized bolted construction, made out of 1.6 mm thick CRCA sheet and built upon rigid framework, having MPP- HD box type capacitor with 7% aluminium wound reactor units type tested in accordance with fully type tested at an Independent laboratory and conforming to IEC 61439-1&2 and IEC 61921 or IS 16636: 2017 with contactor switching, IP 4X protection and including air system provided by axial flow fan or centrifugal fan, control wiring with FR-LSH copper wires complete as specified and directed by the engineer-in-charge. |
| 44 | The APFC Capacitor Bank shall comprise of the following:[i] 40A, 415 V, Ics = 100% Icu = Icw (1 sec for total selectivity) = 16 kA, 50 Hz electrical draw-out type 4P MCCB, conforming to IS/IEC 60947-2 & 3, having 100% neutral with inbuilt release protection, no derating up to 50 ⁰C, thermal based trip & LED based display systems with thermal memory providing overload, short-circuit, instantaneous & earth-fault protection, zone selective interlocking, pre-trip alarm & individual fault indicating LEDs, 20 trip record, % loading, bar graph, max. & min. meter and pre-alarm function for overload, short-circuit & earth fault - 01 Nos.[ii] High performance microprocessor based APFC relay with 3 CT sensing auto / manual switch option- 01 Nos.[iii] MPP-HD box capacitor of 25 kvar (2 X 10 + 1 X 5 ) kVAr - 3 steps |
| 45 | (D) HOT WATER SUPPLY WORKS |
| 46 | Supply, installation, testing and commissioning of Monoblock, self-priming, single-stage centrifugal pump, capable of 3 LPS discharge at 21 MWC head, 2 HP pump having cast iron casing, enclosed type dynamically balanced cast iron impeller, carbon steel pump shaft, gland packed sealing, deep groove ball bearings, etc. with SPDP squirrel cage induction motor having class 'B' insulation, IE2 efficiency, conforming to IS 12615: 2018 and suitable for operation on three-Ph, 415 V±10%, 50 Hz AC supply, base plate, mounting channel frame, accessories and fittings, viz. pressure gauges, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting along with accessories complete all as specified and directed by engineer-in-charge. (1 W + 1 S) (MPM 1018 CAT-A, MECHANICAL SEAL) Note:- [i] Necessary civil work viz. foundation for placement of pump and accessories shall be covered in the scope of work. |
| 47 | Supply, installation, testing and commissioning of self supporting vertical shell, package type compact centralized HSD/Kerosene Oil Fired Storage type Water Heater/ Hot Water Generator of capacity 50000 Kcal/Hr, hot water output at 75 degree Celcius of 1000 Itrs capacity, complete with inbuilt combustion chamber, fire tubes and equipment automatic monoblock bumer assembly with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, suitable for operation on 50 Hz, single phase 220/230 Volts with thermostat, duly insulated with 50mm thick fiber glass insulation wool 48 Kg/Cum density with powder coated/ prepainted sheet metal cladding, automatic air release valve, safety valve, pressure gauges, MS oil storage tank of thickness of walis not less than 3mm and having 200 ltrs capacity, complete all as specified and directed. (2W+1S)Make:- Rapid Cool or equivalent of make as specified in tender documents. |
| 48 | Supply, installation, testing, and commissioning of Fully automatic 2 HP DOL starter three phhase, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type three phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. |
| 49 | (E) CENTRAL HEATING SYSTEM Please Enable Macros to View BoQ information |
| 50 | (E) CENTRAL HEATING SYSTEM Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysOct 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender