Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57219518

Tender For Repair To Compound Wall And Fencing In The Area-I Aor Of Age B/R-I Under Ge(P) Jabalpur

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
8 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair To Compound Wall And Fencing In The Area-I Aor Of Age B/R-I Under Ge(P) Jabalpur

BOQ

Name of Work:- REPAIR TO COMPOUND WALL AND FENCING IN THE AREA-I AOR OF AGE B/R-I UNDER GE(P) JABALPUR
Sl. No. Item Description
1M&L for Site clearance incl cutting of small bushes, hedge, tress under 30cm girth incl surface dressing not exc 15cm deep as in any type of soil and removing of soil/ debris outside MoD land n exc 2.5 Km complete all as specified and directed.
2Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars, etc, built in cement mortar complete all as specified and directed.
3M&L for brick work with flyash bricks , using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
4Dismantling jarfi wall/RCC jallies fixed in rcc post complete all as specified and directed.
5Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, n exc 10 sqm on plan and n exc 1.5m in depth and getting out any type of soil complete all as specified and directed.
6M&L for Cement concrete type D-2 1:4:8 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
7M & L for RCC (Design mix M-25) in foundations, including, rafts, footings, foundation beams, bases for columns, etc , basement slab, under reamed piles and mass concrete complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item.
8M & L for RCC M-25 design mix as in columns , pillars, piers, posts and struts etc. complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item.
9M & L for RCC (Design mix M-25) in beams, cantilevers, bressumers, lintels over 1.50 m span complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item.
10Use and waste flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work, vertical or to batter complete all as specified and directed.
11Use and waste flat fair finish formwork to sides of pillars, posts, struts, piers, columns etc square or rectanguar complete all as specified and directed.
12Use and waste flat fair finish formwork to sides and soffits of floor beams, roof beams , beam haunchings girders, lintels, cantilevers etc to plain surface complete all as specified and directed.
13Removing excavated materials n. exc. 50 m and depositing were directed at a level n exc 1.5 mtr above the staring point complete all as specified and directed.
14Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed.
15S&F TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all as specified and directed.
16S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders complete all as specified and directed.
17Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
18Demolition of PCC of any description and any position not otherwise provided for complete all as specified and directed.
19M&L for Hand rails, half round or other steel section or core for woodenhand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and directed.
20M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and strainingand fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed.
21M&L for 15 mm thick rendering in CM 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work, finished fair and even complete all as specified and directed.
22M&L for waterproof cement based putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the plastered New/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface complete all as specified and directed.
23M&L for preparation of old/New surface ( Plastered or unplastered) of walls and applying two coat of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as specified and directed.
24M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified and directed.
25M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
26Supply and fixing in repir Concertina Coil Mild steel punched tape concertina coil with Zinc coating 450mm Ø with clips spaced 24mm dispensed in compact rolls weighing 7.5 kg/coil covering an average span of 7.5m on expansion to be laid between the 'Y' angle pickets joining by welded at 45 degree slope LAIP. complete all as specified and directed.
27M&L for as in repair Black colour solid ACP wall lining consisting of 3mm thick plain inclusive of solvent cement /Adhesive including Alluminium frame work complete all as specified and directed.
28M&L for as in repair for SS Box type LettersHeight 12\\" to 18\\" including Led Lighting and connection up to Main Socket/DB Nos of Letters up to 40 white fixed to ACP sheet as in repair complete all as specified and directed.
29M&L for as in repair LOGO 0.5 to 1.0 m height with LED module & power supply cable DB etc as in repair complete all as specified and directed.
30Dismentling of chain link fencing wire mesh any type complete all as specified and directed.
31Dismantling posts or struts concrete work or brick masonry (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
32S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
33Dismantling of fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
34Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil complete all as specified and directed.
35Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
36Supply only chain link fencing, any width and dia of wire not less than 3.00 mm complete all as specified and directed.
37M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for securing chain link fencing complete all as specified and directed.
38S&F framed work as in doors or gates of angle or other section with gussest plates, rails, braces,incl grill, grating etc, complete drilled for fixing and incl steel sheeting or other covering doors etc, to be prepared for hanging and sliding with and including either hooks and hinges or steel hnging door fittings and fixing complete conferming to gde Fe 410-w complete all as specified and directed.
39M&L for vetrified paver ceremic tiles 10 mm thick, in light shade, (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
40M&L for vetrified Extrior Elevation tile ceremic tiles 8-10 mm thick, in light shade, (Square/rectangular) polished in floors/Wall etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed.
41M&L for Granite (of any type) tiles 16 to 18mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including jointing with solvent, grinding, rounding to edges and polishing complete as in plateform etc complete all as specified and directed.
42M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
43M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
44M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
45S&F Vitrous China Porcelaine glazed tile 5-6 mm thickness (or match with existing tile) set and jointed with gold type ready made adesice as in swimming pool etc as in repair complete coloured and design complete all as specified and directed.
46S&F in repairs E-boards, ceiling, 4 mm thick with J framed work with main Tee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cm x 4mm thick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and incl making good of all disturbed/daimage surface of walls and applying two coat of oil bound distemper complete all as specified and directed.
47Dimantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings roofing complete all as specified and directed.
48Dimantling of PVC fibre roof sheeting, corrugated or semi corrugated or similar pattern roof coverings complete all as specified and directed.
49M&L for Pre-painted galvatume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
50M&L for Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
51Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
52Schedule of credit of Amount Rs. 36,210.00 to be deducted during AOC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57219518
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 17-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Compound Wall And Fencing In The Area-I Aor Of Age B/R-I Under Ge(P) Jabalpur
Basic Detail
Tender No 8661/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 27 Aug 2026
Submission Date 17 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
8661TenderDocuments.pdf
aee76279-c3d1-48b1-9887-8dfa3a8cb8e2.html
BOQ_881401.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

8661TenderDocuments.pdf

html

aee76279-c3d1-48b1-9887-8dfa3a8cb8e2.html

xls

BOQ_881401.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders