Tender For Provision Of Changing Room For Swimming Pool, Gym Near Sports Complex, 02 Split Ac At Mrsa And Addn/Altn At Auditorium (Wall Paneling, Flooring, Toughen Glass) Under Ge (West) Jrc
Tender Value
31.40 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
11 days left
EMD
62800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Changing Room For Swimming Pool, Gym Near Sports Complex, 02 Split Ac At Mrsa And Addn/Altn At Auditorium (Wall Paneling, Flooring, Toughen Glass) Under Ge (West) Jrc
BOQ
| Sl. No. | Item Description |
| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer (West) Jalandhar Cantt Name of Work : Provision of Changing Room for Swimming Pool, Gym near Sports Complex, 02 Split AC at MRSA and Addn/Altn at Auditorium (Wall Paneling, Flooring, Toughen glass) under GE (West) JRC Contract No : GE/JAL(W)-40/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches n.exc 15 m wide and n.exc 1.5 m deep for foundations, etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 Sqm on plan and getting out in ordinary soft/loose soil |
| 3 | M&L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregates ) lean concrete as in foundation, filling and mass concrete complete all as specified . |
| 4 | M&L for RCC design mix M-25 concrete (using 20mm graded stone aggregate), as in Foundations, including rafts, footings, foundation beams; plinth beams; base for columns, etc basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 5 | M&L for RCC design mix M-25 concrete (using 20mm graded stone aggregate), as in Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 6 | M&L for RCC design mix M-25 concrete (using 20mm graded stone aggregate), as in roof beams, cantilevers, bressummers, lintels upto and over 1.5 m clear span, complete all as specified and directed. |
| 7 | Use & waste formwork for rough finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 8 | Use and waste formwork for fair finished surfaces to square/reactangular sides of pillars, posts, struts, piers, columns, and stanchions fair and finished surface, complete all as specified and directed. |
| 9 | Use & waste formwork for fair finished surfaces to sides and soffits of floor or roof beams, beam, RCC coping fair and finished surface, complete all as specified and directed. |
| 10 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 11 | Returning filling in including, spreading, levelling, watering and well ramming in layers not exc 25 cm soft/loose soils. |
| 12 | Removing excavated material n exc 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soils. |
| 13 | M&L rendering 12 mm thick in Cement Mortar 1:6 on fair faces of Brick Walls or on Concrete Surfaces, finished Even complete all as specified and as directed. |
| 14 | M&L plastering in cement mortar 1:4, 15mm thick on fair faces of brick/concrete wall surfaces and finishing even complete all as specified and as directed. |
| 15 | M&L for preparation of new surfaces of walls including cornices pilasters etc, applying two coats of oil bound distemper over a coat of primer complete all as specified. |
| 16 | M&L for preparation of new surfaces of wall including cornices, plasters etc (Plastered or unplastered surfaces) and applying two coats of cement base paint complete all as specified. |
| 17 | M&L TMT bars 10mm dia and over, cut to length, bent to shape as required incl cracking bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed |
| 18 | All as per item No 16.00 above but 5 mm dia and over upto and including 10 mm dia inserting, spacers and binders |
| 19 | M&L hard core of broken stone or boulders of gauge n. exc 63 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rammed to a true surface |
| 20 | M&L 75mm thick PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in plinth protection and finished concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 21 | M&L PCC sub base 75mm thick, type D2, 1:4:8(40mm grade aggregate) |
| 22 | M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as a leveling concrete in floor finishing concrete complete all as specified and directed. |
| 23 | M&L for italian vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, in floors etc, laid over and including15mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 24 | M&L for 20mm thick Z black Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed |
| 25 | Rolled sections as in main and cross beams, hip and jack rafters; purlins of Fe 410 W (gde- E-250) quality A where connected to common rafters and and connecting platesguides for sliding doors; fixed with angle cleats or other running rails |
| 26 | Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 27 | S& F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 28 | S& F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, facia fixed with self tapping screws as specified |
| 29 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified. |
| 30 | S& F Toughned glass 12.0 mm thickness as in hinged doors,partitions automatic doors and similar work including fittings, cutting to shape, drilling holes required . |
| 31 | S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed. |
| 32 | S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters,aluminium section weighing not less than 0.55 kg/m including necessary joining cleats,cglazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, canodised aluminum snap beading screws etc, complete all as specified and directed. |
| 33 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) for sliding window shutters with frame including providing and fixing roller, three track system, locking arrangement fittings wherever required including the cost of 4.80mm thick sheet glass(selected quality), EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws where necessary all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 34 | S&F anodised Aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 35 | S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, complete all as specified and directed. |
| 36 | S&F 5.5mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and directed. |
| 37 | S&F stainless steel steel butt hinges cold rolled of size 100mm medium weight, complete all as specified and directed. |
| 38 | S&F Aluminium handles, cast type anodised of size 100mm etc, complete all as specified and directed. |
| 39 | S&F Aluminium handles, cast type anodised of size 150mm etc, complete all as specified and directed. |
| 40 | S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed. |
| 41 | S&F Aluminium anodised, barrel tower bolts 200mm long of extruded section and fixed, complete all as specified and directed. |
| 42 | S&F aluminium (aluminium body) door closer hydraulically regulated designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed in repair complete all as specified and directed. |
| 43 | Providing and fixing PVC hollow wall paneling for ceiling, comprising 6 mm thick hollow cellular PVC panels of approved colour, texture and design, fixed on aluminium/G.I. framework with suitable channels, cleats, screws and accessories, including perimeter trims, cutting and making openings for electrical fixtures, complete in all respects as per manufacturer's specifications and direction of Engineer-in-Charge |
| 44 | Excavating in post holes(or similar holes) each n exc 0.5 Cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50m and making good surface complete. |
| 45 | M&L for first quality anti-skid / non-skid glazed vitrified tiles conforming to IS:15622, of size 600 × 1200 mm and approved make, on floor surface using polymer modified tile adhesive conforming to IS:15477, including filling joints with epoxy/cementitious grout of matching shade, cutting and finishing complete as directed by the Engineer-in-Charge. |
| 46 | Providing and fixing factory-made white uPVC casement openable door made with integrated fixed panel, fabricated from multi-chambered uPVC profiles (Frame: 67x62 mm, Sash: 67x115 mm, T-profile: 78.4x67 mm), 2.3 mm wall thickness ±0.2 mm, duly reinforced with 1.50 + 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),including EPDM gaskets, zinc-alloyed white powder-coated hardware (casement handle, 3D hinges, multipoint lock, striker plates), and provision for 5 mm toughened glass in shutter and 18mm prelaminated uPVC board in fixed panel. Frame fixed with 8 mm x 100 mm anchor fasteners, all as per design and manufacturer specifications. |
| 47 | S& F Toughened glass 5.0 mm thickness as in uPVC doors and similar work including fittings, cutting to shape, drilling holes required. |
| 48 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 49 | Dismantling for Stone slabs and tiles laid bedded and poinded in any morter of any description or thickness in floors, aprons etc. |
| 50 | Supply and fix for solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame wood grain printed PVC sheet used instead of plaincolour sheet as per specification all as specified and directed. |
| 51 | Supply and fix for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed. |
| 52 | S&F Mild steel Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 53 | M&L for point wiring with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLSH cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings and brass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLSH cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed.Note : Cost of Metal boxes and modular accessories like cover plates will be paid seprately in respective items) (a) Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push. |
| 54 | (b) One socket outlet point 5 amps on the same board. |
| 55 | (c) One socket outlet point 5 amps on the independent board. |
| 56 | All as per ser item no 52.00 here in before but with 2.5 sq mm wire and earth wire (green colour) of 2.5 sq mm for 3/5 Pin 16 Amp modular type socket outlet. |
| 57 | Supply and fixing modular metal flush box 3 module complete all as specified and directed. |
| 58 | Supply and fixing modular metal flush box 4 module complete all as specified and directed. |
| 59 | Supply and fixing modular metal flush box 6 module complete all as specified and directed. |
| 60 | Supply and fixing modular metal flush box 12 module complete all as specified and directed. |
| 61 | Supply and fixing modular white cover plate with frame, 3 module complete all as specified and directed. |
| 62 | Supply and fixing modular white cover plate with frame, 4 module complete all as specified and directed. |
| 63 | Supply and fixing modular white cover plate with frame, 6 module complete all as specified and directed. |
| 64 | Supply and fixing modular white cover plate with frame,12 module complete all as specified and directed. |
| 65 | Supply and fixing modular Dummy plate complete all as specified and directed. |
| 66 | Supply and fix Modular switch 6 Amps single pole one way as per make & model/ as per sample . Note : All switches from 6 Amp to 25 Amp should be latest ISI marked as per IS 3854 : 1997 complete all as specified and directed. |
| 67 | Supply and fix Modular switch 16 Amps single pole one way as per make & model/ as per sample . Note : All switches from 6 Amp to 25 Amp should be latest ISI marked as per IS 3854 : 1997 complete all as specified and directed. |
| 68 | Supply and fix Modular multi socket 3 pin and 2 pin 6 Amps round and flat as per make & model/ as per sample . Note : Sockets 6 Amp 3 Pin and 6/16 Amp 3 Pin combined should be latest ISI Marked as per IS 1293 : 1988 and should be supplied with shutters and shutters opening with phase and neutral simultaneously. The range should have all the types of Indian Standard or Multistranded International sockets range in their profilem complete all as specified and directed. |
| 69 | Supply and fix Modular socket 6A /16 A Twin socket heavy duty as per make & model/ as per sample/EIC . Note : Sockets 6 Amp 3 Pin and 6/16 Amp 3 Pin combined should be latest ISI Marked as per IS 1293 : 1988 and should be supplied with shutters and shutters opening with phase and neutral simultaneously. The range should have all the types of Indian Standard or Multistranded International sockets range in their profile complete all as specified and directed. |
| 70 | Supply & fixing ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified. |
| 71 | Supply and fix modular/BLDC fan regulator step type 240 V, 120 W, 2 modules all as as per make & model/ as per sample directed. |
| 72 | Supply and Fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of cap 20A complete all as specified and directed. |
| 73 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type, MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “B” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting complete all as specified and directed. |
| 74 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “C” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting complete all as specified and directed. |
| 75 | S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “B” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting complete all as specified and directed. |
| 76 | S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “C” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting complete all as specified and directed. |
| 77 | Supply and fix Sheet metal DB,double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc. Distribution boards should be Double Door design with IP-43 and IK-08 rating as per IEC 61439-3 with 100 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock complete all as specified and directed . |
| 78 | Supply and fix Sheet metal DB,double door, SPN 12 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc. Distribution boards should be Double Door design with IP-43 and IK-08 rating as per IEC 61439-3 with 100 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock complete all as specified and directed . |
| 79 | Supply & fixing MCCB 4 pole of capacity 100 Amps with breaking capacity 16 Kilo Amps including all electrical connections and fixing arrangment complete all as specified and directed . Note- MCCB Should have reverse load and line termination, rotary handles – direct and variable depth and common auxiliaries for entire range. Should be CE marked and conform to IEC 60947-2. MCCB should have the maximum operational voltage ( Ue ) of 550 Volts (AC 50/60 Hz), Insulation Voltage ( Ui ) of 800 Volts and Rated Impulse Withstand Voltage (Uimp) not less than 8000 volts. The MCCB should have been designed at an ambient temperature of 50 degree centigrade. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED.For 16 – 125 A: Should have breaking capacity of min. 16 kA with thermal release adjustable from 80 to 100 % & fixed magnetic release and with Ics = 100% Icu complete all as specified and directed. |
| 80 | Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars , Neutral links , blanking plates Distribution boards should be Double Door design with IP-43 and IK-08 rating as per IEC 61439-3 with 200 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock complete all as specified and directed . complete all as specified and directed. All 3 Phase horizontal distribution boards should have the provision to convert the distribution boards to Per Phase Isolation Distribution Board at site. All MCCB incomer distribution boards should be supplied with 250 Amp rated fully shrouded busbars complete all as specified and directed. |
| 81 | M&L for concealed conduit sub main wiring of 2 run of single core multi stranded FRLSH PVC insulated and unsheathed copper conductor as per IS-694 FRLSH cable red and black colour of size 6 sqmm 1100 volts grade with 6.0 sqmm multi strand copper conductor PVC insulated and unsheathed cable in green colour earth continuity wire connected to common earth dolly in PVC pipe including cutting chasing complete with all accessories complete all as specified and directed. |
| 82 | M&L for submain wiring with two RUNS of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded FRLSH copper conductor PVC insulated unsheathed cables drawn through and including concealed conduits in wall and necessary cutting and chassing for rigid PVC conduit ISI marked not less than 20 mm dia and all accessories complete all as specified and directed. |
| 83 | M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick bouried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead complete all as specified and directed and as per electric plate No.5 of SSR Part I |
| 84 | Supply and laying XLPE insulated, armoured electric cable heavy duty with aluminium conductor, 1100 volts UG cable of size 4 Core 50 Sqm complete all as specified and directed. |
| 85 | Supply and laying XLPE insulated , armoured electric cable heavy duty with aluminium conductor , 1100 volts UG cable of size 4 Core 35 Sqm complete all as specified and directed. |
| 86 | M & L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed.only punned thickness will be measured. |
| 87 | Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed. |
| 88 | Supply and fixing /laying PVC conduit pipe 100mm bore light grade fixed to pole with clamps nuts, Bend/Tee/Junction box , bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. |
| 89 | Supply and fixing modular metal flush box 1/2 modular complete all as specified and directed. |
| 90 | Supply and fixing modular metal flush box 8 modular complete all as specified and directed. |
| 91 | Supply and fixing modular white cover plate with frame ,1/2 module complete all as specified and directed. |
| 92 | Supply and fixing modular white cover plate with frame ,8 module complete all as specified and directed. |
| 93 | S & F lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed. |
| 94 | S & F LED lamp 9 watt polycarbonate complete all as specified and directed. |
| 95 | Supply and fixing in replacement of LED tube light fitting for all purpose surface and wall mounted with single side connection polycarbonate LED batten with alumimium housing and integrated electronic driver of capacity 20 W , four feet and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. |
| 96 | S & F LED 9/10 Watt tube light 2 Feet LIGHT fitting complete with all acessories 1x9 Watt LED, with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed. |
| 97 | Supply and fix of security light fitting LED 35 Watt with dusk and down sensor aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size GI Bracket and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fitting all as specified and as directed. |
| 98 | M & L for sub main wiring with two single core PVC insulated and unsheathed cable 10 sqmm with multi stranded copper conductor , FRLSH type cable drawn through and including PVC concealed conduit not less than of 25mm in size complete with all accessories alongwith provn of 1 run of 10 sqmm PVC insulated and unsheathed, multi stranded copper conductor, FRLSH type cable as earth wire (Three runs of cable and one run of conduit shall be measured as one length) complete all as directed. |
| 99 | S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “C” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting complete all as specified and directed. |
| 100 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “C” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting complete all as specified and directed. |
| 101 | Supply, Install, Testing and Commissioning hi wall split units indoor/outdoor complete with cordless remote control unit and with cooling and heating function with in built air ioniser and Plasma filter for better indoor air quality, low noise level, hi grooved copper condensor coil & evaporator with aqua clear protection, dual filtration, leakage detector and safety sensor, all standard accessories, interconnecting copper tubing, drain pipe, power cable, insulation, first charge of refrigerant, mounting bracketts, auto cleanser with 3/5 star rating and EER 3.2.of capacity 1.5 TR including all necessary connection and commissioning in all respect conforming to IS 1391 (Part 2) and BIS approved complete all as specified and directed. |
| 102 | Supply, Install, Testing and Commissioning Voltage stabilizer for automatic operation, Copper wound ,single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender