Metro Rail Boards / Undertakings / PSU Closing in 7 days TDR #57217807

Tender For Electrical Work At Akshardham Metro Stations Under Renovation Of Station Over L-3E&4.

Issued by Boards / Undertakings / PSU · New Delhi, Delhi
Tender Value
35.41 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
7 days left
EMD
70827
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Work At Akshardham Metro Stations Under Renovation Of Station Over L-3E&4.

BOQ

Name of Work:- Electrical work at Akshardham Metro stations under Renovation of station over L-3E&4.
Sl. No. Item Description
1Total of Schedule-A
2Total of Schedule-A Contract No- E/EM/L-3Eand4/2026/03 APPENDIX- 3A PROFORMA FOR STATEMENT OF MINOR DEVIATIONS (Refer Clause C 2.2(d) and C 15.1 of ITT) 1. The following are the particulars of minor deviations from the requirements of the Tender Document: Sr. No Clause Deviations Price reduction for each deviation/s Note : 1. The Tenderer shall indicate price reduction against each deviation in Appendix-3A of BOQ. This price is the price which the tenderer shall reduce from this tender price if deviation(s) is/are accepted by the Employer. 2. Where there is no deviation, the statement should be returned duly signed with an endorsement indicating ‘No Deviations’. In case, Performa of deviations is not submitted or submitted as blank, it will be construed that the tenderer has not proposed any deviations from tender documents. 3. It shall be noted that in case Nil/Zero/NA Price quoted by Tenderer in Appendix-3A then it shall mean that contractor has quoted same price for deviation and undeviation bid. 4. If the tenderer proposes deviations in tender documents, and/or any other terms and conditions of the tender, other than in this Appendix, it will have no effect. Signature of authorized signatory On behalf of Tenderer Contract No- E/EM/L-3Eand4/2026/03 S. No. Preamble
3The bill of Quantities shall be read in conjunction with Notice Inviting Tenders, Instructions to tenderers, Special Conditions of contract, Employers Requirements, Technical Specfications, GCC etc.
4BoQ consists of one schedules i.e. Schedule-A.
5Tenderers shall quote their offer in Indian Rupees (₹) only. Tenderers are required to quote percentage (%) (Excess/Less) in figures in the appropriate highlighted cells in Excel sheet namely 'BoQ1' against given schedules.
6The rates and prices to be tendered in the unit Priced Bill of Quantities are for completed and finished items of works and complete in all respect. It will be deemed to include Duties, Taxes, Octroi, Royalty etc., cost of all plants, labour, supervision, materials, transport, all temporary works, erection, maintenance, utility identification, contractor’s profit and establishment/overheads, together with preparation of design and drawings, all general risks, insurance liabilities, compliance of labour laws and obligations set out or implied in the contracts. For taxes and duties refer clause C2.4 & C2.5 of ITT & clause 10 of SCC.
7If the tenderer fails to quote rates against any item, the tender may be treated as incomplete and non-responsive and shall be rejected.
8Errors will be corrected by the employer for any arithmetical errors in computation or summation as per contract conditions.
9The Financial Proposal (as per BOQ) shall be uploaded online on the website http://eprocure.gov.in/eprocure/app. The rates shall be quoted in the excel file provided in the bid documents. The tenderer shall download the excel file and quote the rates in BOQ1. After quoting their rates the excel file shall be uploaded accordingly. The rates shall not be offered/quoted elsewhere in the technical submission/ tender submission.
10The actual work executed against all the BOQ as detailed in tender document would be paid as per clause-16 of ER.
11The price offer in BOQ shall be given without consdering any deviation mentioned in Appendix-3 of FOT i.e. price in this box shall be quoted as per tender condition without any deviation. Bill of Quantity (BOQ) Name of work: Contract:-E/EM/L-3Eand4/2026/03 “Electrical work at Akshardham Metro stations under Renovation of station over L-3E&4”. Sl. No. DESCRIPTION Unit Qty Rate (₹) (Excl. GST) Amount (₹) Schedule-A i Supplying and fixing of following sizes of GI conduit medium class along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making the good the same in case of recessed conduit as required. a 25 mm Metre 800.0 167.85 134280.0 ii Supplying and fixing of 25 mm dia GI flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required Metre 350.0 34.75 12162.5 iii Dismantalling of existing wire/cable upto size of 10 Sq.mm from conduits or as per requirement site condition. Mtr 2500.0 15.93 39825.0 iv Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. a 3x1.5 sqmm Metre 1000.0 39.41 39410.0 b 3x2.5 sqmm Metre 500.0 55.48 27740.0 c 3x4.0 sqmm Metre 500.0 85.46 42730.0 v Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required a 2X1.5 sqmm + 1X1.5 sqmm earth wire Metre 1000.0 146.38 146380.0 b 2X2.5 sqmm + 1X2.5 sqmm earth wire Metre 600.0 162.43 97458.0 c 2X4.0 sqmm + 1X4.0 sqmm earth wire Metre 300.0 187.15 56145.0 B. Cabling i Laying and fixing of one PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a upto 35sqmm (Clamped with 1mm thick saddle) Metre 200.0 36.06 7212.0 ii Laying and fixing of one PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. a upto 35sqmm (Clamped with 1mm thick saddle) Metre 200.0 29.51 5902.0 iii Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Each 20.0 26.23 524.6 iv Supplying and fixing 20A, 240V, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A \\"C\\" curve, SP, MCB, in sheet steel enclousre, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Each 37.0 1062.83 39324.71 v Excavation of trench by demolishing of RCC/Stone/Bituminus, removal of pavers & exacvation of trench for cable laying upto depth of 800mm and 400mm width preparation of sand bad, covering of cable with A class brick ( Min. 19brick/meter), refilling, refixing of pavers & bring in original condition . Mtr 300.0 190.42 57126.0 C. Distribution Board i Supplying and fixing following rating, doble pole, (Single phase and Neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a 25A Each 50.0 1329.69 66484.5 b 40A Each 50.0 1732.26 86613.0 D.Earthing i Providing and fixing 25mm X 5mm GI strip on surface or in recess for connections etc as required Confirming to relevant BIS/IS with samples need to be approved by DMRC Engineer In-charge. Metre 120.0 159.98 19197.6 E. Switch & Sockets i Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a 5/6A Switch Each 60.0 55.49 3329.4 b 15/16A Switch Each 81.0 85.62 6935.22 c 3 pin 5/6A socket outlet Each 50.0 70.7 3535.0 d 6 pin 15/16A socket outlet Each 71.0 112.12 7960.52 ii Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.Confirming to relevant BIS/IS with samples need to be approved by DMRC Engineer In-charge. a 3 Module (100mmX75mm) Each 31.0 135.0 4185.0 b 4 Module (125mmX75mm) Each 21.0 145.0 3045.0 iii Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. a 1 or 2 Module Each 40.0 73.7 2948.0 b 3 module Each 30.0 82.99 2489.7 c 4 module Each 20.0 88.79 1775.8 F.Joints & Termination i Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a 4x10 sqmm (25mm) Each 10.0 158.42 1584.2 G. Miscellaneous i Installation, testing and commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required Each 346.0 78.03 26998.38 ii Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00,Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019) THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Nos 40.0 2359.83 94393.2 iii Painting on GS sheet with synthetic enamel paint of approved brand and manufacturer of required colour to give an even shade:- a Old work (One or more coats) sq. Mtr 4000.0 50.62 202480.0 iv Dismantalling of existing different capacities and type of light fitting from wall/ceiling/fabricated beam stairs upto the height of 30 feet. Nos 100.0 217.03 21703.0 v Supply installation of modular Double 6/16 A Switch socket combined box Nos 32.0 356.23 11399.36 vi Fixing/grouting of DFMD with 4/2 nos. suitable size screw/fastners Nos 10.0 98.25 982.5 vii Re-wiring/Laying of wire/cabes (armoured/unarmoured) from its existing position size upto 10 sq.mm 3/4 core cable of X ray machine/DFMD supply in arrangement of SS pipe and switch/Socket, complete with routing of wire/cable, making hole in SS pipe, termination and earthing etc as per site requirement. Mtr 240.0 15.18 3643.2 viii Supply and installation Top plug of 6 A as per empanelled make of DMRC. Nos 50.0 41.98 2099.0 ix Supply and installation Top plug of 16 A, make as per Employer Requirement as per empanelled make of DMRC. Nos 50.0 54.48 2724.0 x Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Each 7.0 112.46 787.22 xi Supply and installation of MS junction box made by 16 gauge MS sheet suitable for mounting on street light pole duly painted with epoxy grey colour paint.Confirming relevant IS. Nos 20.0 403.17 8063.4 xii SITC of Lights a Supply, Installation, Testing & Commissioning (SITC) of 250mm- 300mm X 1200mm Surface/Recessed Mounted 4ft. Luminaire with a nominal system lumen output of 3600 and a minimum system efficacy of 120 lm/W. The total power consumption should not exceed 28W (including driver). Nos 275.0 2772.23 762363.25 b Supply, Installation, Testing & Commissioning (SITC) of LED based Flood light. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 3500 lumens and maximum system wattage of 35 Watts (including driver). Nos 71.0 2451.88 174083.48 c Supply, Installation, Testing & Commissioning (SITC), Installation, Testing and Commissioning of LED Post Top with a system lumen output of 2700 lumens and a minimum system efficacy of 120 lm/W. The total power consumption should not exceed 27W (including driver) Nos 60.0 4546.45 272787.0 xiii Modification in Existing LDB. a Replacement of Rusted parts of LDBs sq. Mtr 150.0 180.0 27000.0 b Dressing of Cables, Wires inside LDBs along with replacement of defective connectores, thimbles etc as per conditions and site requirements. Job 16.0 2000.0 32000.0 d Uplifting of existing old LDBs along with all associated required works. Job 1.0 5000.0 5000.0 xiv Dismantling of Old CU pipe along with sifting of released scrap to YBD Store (Transportation included) MTR 150.0 250.0 37500.0 xv DG 125 KVA a Repairing of Fresh air Duct Job 1.0 10000.0 10000.0 b Repairing of DG Base & Painting Job 10.0 10000.0 100000.0 c Repairing of Exhaust Duct Job 1.0 10000.0 10000.0 xvi RACEWAY a Replacement 300 MM GI Raceway at PF level during non-revenue hours along with dismantling of old raceway, Dismantling & installations of Light Fixtures (including cost of accesseries) as required at work site Mtr 40.0 2000.0 80000.0 xvii Supplying and installing following size of perforated hot dipped galavanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with GI suspnders including GI bolts and nuts etc as required a 150mm width X50mm depth X1.6MM thickness Mtr 200.0 488.4 97680.0 b 300mm width X50mm depth X1.6mm thickness Mtr 154.0 656.88 101159.52 Total Schedule A (Without GST) 3001149.26 GST@18% 540206.87 Total Schedule A (Including GST) 3541356.13 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57217807
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 35.41 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Delhi Metro Rail Corporation Limited
Work Description Tender for Electrical Work At Akshardham Metro Stations Under Renovation Of Station Over L-3E&4.
Basic Detail
Tender No E/EM/L-3Eand4/2026/03
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 27 Aug 2026
Submission Date 21 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 35.41 Lakhs
Tender Fee 5900
EMD 70827
Exemption Not Available
Document List
BOQ_970547.xls
d89332f5-f036-4bed-a7f0-3d56ef5ce321.html
Tendernotice_1.pdf
Tender_EEML-3Eand4202603.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_970547.xls

html

d89332f5-f036-4bed-a7f0-3d56ef5ce321.html

pdf

Tendernotice_1.pdf

rar

Tender_EEML-3Eand4202603.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders