Tender For Raising The Height Of Main Plant Chain Link Fencing, Installation Of View Cutter In Main Plant Boundary Fencing And Provision Of Chainlink Fenicng With Concertina Coil For Sodium Plant At Hwbf, Vadodara.
Tender Value
49.17 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
7 days left
EMD
98344
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Raising The Height Of Main Plant Chain Link Fencing, Installation Of View Cutter In Main Plant Boundary Fencing And Provision Of Chainlink Fenicng With Concertina Coil For Sodium Plant At Hwbf, Vadodara.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and refixing of expanded metal or IRC fabrics or chain link fencing with necessary battens and beading including stacking the serviciable material within 50 Meters lead. |
| 2 | Demolishing of RCC, PCC by mechanical/hand means and stock piling at designated locations, chipping, etc. and disposing off all the debris outside the plant premises, stacking, serviceable and unserviceable material so separately including cutting, reinforcement, etc. complete as directed. |
| 3 | Demolishing brickwork masonary by mechanical means including stacking of serviceable material disposing of all debris outside the plant premises at the risk and cost of the contractor and as directed by the Engineer. |
| 4 | Dismantling and stacking within 50m lead, fencing angle post or struts including all earth work and dismantling of concrete below post including removing all the material bonded to the post etc. complete as directed by Engineer. |
| 5 | Dismantling barbed wire, concertina coil or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 6 | Earth work in excavation in all types of soils for foundation, trenches or drains not exceeding 1.5 M in depth and getting out the excavated soil and disposal of surplus excavated earth outside the plant premises at risk and cost of the Contractor, including cost of backfilling of footings, trenches etc. complete and as directed by the Engineer. |
| 7 | Providing and laying plain cement concrete (1:2:4) (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) of approved quality in foundation, plinth, payements, (plinth beams and under floor)including ramming, leveling, curing, form work,shuttering wherever necessary etc. all complete as per drawings, specifications and as directed by the Engineer. |
| 8 | Providing and laying reinforced cement concrete M-25 using approved size of graded stone aggregate and proportion 1:1.5:3 (1 part cement : 1.5 sand : 3 aggregate 20mm down gauge graded stone aggregate of approved quality including consolidating, leveling, finishing, curing, etc. all complete at all levels upto 15 meter height as per drawings, specifications and as directed by the Engineer but excluding cost of reinforcement bars including compaction and curing, etc. complete and laying at reinforcement for reinforced concrete work in foundations, footings, bases of columns, walls, suspended floors, roofs laying shelves and their supports balconies, lintels, beams, girders, cantilever columns as per drawings, specifications and as directed by the Engineer. (Excluding cost of centering and shuttering. ) |
| 9 | Providing,laying & fixing in position TMT bars of grade Fe 500 D (IS 1786) or more for reinforcement at all levels, for RCC in situ work including cost of straightening, cutting, bending & binding with 16 gauge MS annealed binding wire, cement mortar spacer blocks, etc. all complete as per drawings, specifications and as directed by the Engineer. |
| 10 | Providing and fixing, centering and shuttering including strutting propping, etc. for RCC works including removal of form work after concreting for foundation footing base of Column, PCC, Plinth, beams, coping, slab, etc. complete as directed by the Engineer. |
| 11 | Providing and laying 15mm thick plaster in cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement inside surface proportion over brick masonry walls upto 15 mtr. height and concrete surfaces including raking of joints, hacking of concrete surfaces, curing, scaffolding, providing grooves etc. all complete as per drawings,specifications and as directed by the Engineer. |
| 12 | Providing, fabricating, erecting and fixing in position at all heights upto a maximum height of 15 mtrs. with welded/bolted connection to all structural steel works for platform, stairs, ladders, beams, joints, bracings, columns, built up Section, gate fabrication etc. by using plates, beams, channels, angles, pipes, etc. conforming to IS 2062 of approved manufacturer including cost of all material labours, tools and tackles, machines, safety appliances, scaffolding, etc. including applying a priming coat of suitable steel primer, all complete and as directed by the Engineer. |
| 13 | Encasing rolled steel sections,beams and columns,with cement concrete 1:2:4 (1 Cement: 2 Coarse sand : 4 graded stone aggregate 12.5 mm nominal size) including centering and shuttering complete but excluding cost of reinforcement. |
| 14 | Providing and applying two or more coats of exterior emulsion of Premium Acrylic smooth exterior paint with silicon addetive of APEX of ASIAN or equivalent make of approved brand and manufacturer and of required shade applied @ 1.43 lit/10 Sqm.over and including priming coat of exterior primer applied @ 0.9 lit/10 Sqm to give an even shade; including cost of scaffoldings, etc. at all heights as per specifications and as directed by the Engineer.(In any case it will not be permitted to carry out the job without proper metallic scaffolding and platform at height more than 2.5 m) |
| 15 | Fixing fencing with barbed wire concertina coil 600 mm dia having 50 rounds per 6 meter length fixing upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.0 to 3.00 m apart and with 9 horizontal barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, Note: Dismantled concertina and barbed wire under item no. 5 shall be used for this work. Cost includes required tools, tackles, fittings, clips etc required for fixing the coil except cost of concertina coil and barbed wires. |
| 16 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, including safe scaffolding all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 17 | Providing and fixing colour coated corrugated galvalume profile sheets of TATA/JSW or equivalant make (Profile, Colour and shape as approved by the Engineer-incharge) of 0.60mm(TCT) total coated thickness (tolerance as per relevant IS code) with material yield strength 550 MPa, galvalume AZ-150 (zinc aluminium alloy coating nominal composition : 55% aluminium, 43.5% zinc & 1.5% silicon mass total of both sides) with regular modified polyester paint and coating of 20- 25 micron RMP on exposed surface including primer and 7-10 micron epoxy coating on unexposed surface including primer. The sheet should be supplied in single length as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping screws with EPDM seal and washers of make- Coroshield/ durotuff / polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers( as per engineer in charge) including cutting to size and shape wherever required, finishing the surrounding for filling the gap between wall and sheet by providing & applying Cement mortar 1:4 (1: Cement : 4 Sand), etc. complete as per the specifications and as directed by EIC. Note :-1. All screw should be sealed with silicon sealant to make the sheet as leakproof.2. Measurements will be given only for covered Roof area and over laps will not be measured or paid separately.3. Rate quoted shall be inclusive of finishing work required for filling the gaps between wall and sheet, nothing extra will be paid on this account. Please Enable Macros to View BoQ information |
| 18 | Providing and fixing colour coated corrugated galvalume profile sheets of TATA/JSW or equivalant make (Profile, Colour and shape as approved by the Engineer-incharge) of 0.60mm(TCT) total coated thickness (tolerance as per relevant IS code) with material yield strength 550 MPa, galvalume AZ-150 (zinc aluminium alloy coating nominal composition : 55% aluminium, 43.5% zinc & 1.5% silicon mass total of both sides) with regular modified polyester paint and coating of 20- 25 micron RMP on exposed surface including primer and 7-10 micron epoxy coating on unexposed surface including primer. The sheet should be supplied in single length as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping screws with EPDM seal and washers of make- Coroshield/ durotuff / polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers( as per engineer in charge) including cutting to size and shape wherever required, finishing the surrounding for filling the gap between wall and sheet by providing & applying Cement mortar 1:4 (1: Cement : 4 Sand), etc. complete as per the specifications and as directed by EIC. Note :-1. All screw should be sealed with silicon sealant to make the sheet as leakproof.2. Measurements will be given only for covered Roof area and over laps will not be measured or paid separately.3. Rate quoted shall be inclusive of finishing work required for filling the gaps between wall and sheet, nothing extra will be paid on this account. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender