Water Resources and Irrigation Boards / Undertakings / PSU Closing in 1 days TDR #57214520

Tender For Nit For Construction Of Toilet At Premises Of Store And Transport Sub- Division, Bbmb (Pw), Slapper.

Issued by Boards / Undertakings / PSU · Mandi, Himachal Pradesh
Tender Value
5.61 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
1 days left
EMD
11240
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mandi → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Nit For Construction Of Toilet At Premises Of Store And Transport Sub- Division, Bbmb (Pw), Slapper.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 03-Sep-2026 NIT FOR CONSTRUCTION OF TOILET AT PREMISES OF STORE AND TRANSPORT SUB-DIVISION, BBMB(PW), SLAPPER. Date 09-Sep-2026

BOQ

Name of Work:- NIT for construction of toilet at premises of store and transport sub- division, BBMB (PW), Slapper.
Sl. No. Item Description
1Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
2Cement concrete 1:4:8 (b) With stone aggregate 40mm gauge(ii) mixing by mechanical means using concrete mixer volumetric type
3First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
4Damp proof course 2.5cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded
5First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level.
6Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
7Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
8Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
9Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
10Providing and fixing 1st quality ceramicglazed wall tiles Matt/Semi Matt/ Glosy/ Highly Gloss finish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
1112.5 mm thick cement plaster 1:4
12Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
13Distempering with Acrylic washable oilbound distemper(of approved manufacture) two or more coats over one priming coat to give an even shade
14Finishing walls with textured exterior paint of required shade with two or more coatsapplied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
15Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. (a) Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect.
16Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
17Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. (iii) Size 630 mm x 450 mm x 830 mm
18Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. (i) Vitreous chinaware standard white pedestal for wash hand basin.
19Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. (a) C.P. brass toilet paper holder
20Providing and fixing in position towel rails /ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugsembedded in walls with brass screws complete in all respect. (b) C.P brass towel ring
21Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
22Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (a) Size 600mmx450mm
23Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.(a) C.P. brass Bib cock long nose/long body foam flow without flange
24Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. (a) C.P.brass 15mm stopcock Male and female end
25Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. (f) PVC tube connection of size 15mm x 600 mm with C.P. Brass nut
26Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A(a) 160mm o/d single socket SWR UPVC pipe lines laid complete
27Providing and fixing in position C.I. gully trap cover weighing approximately 7.26 kg and frame for gully trap chamber clear opening size 300mm x 300mm and out side size 330mmx330mm including painting the exposed surface with 3 coats of black bitumastic superior paint of approved manufacture etc.
28Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. (a) With 100mm x 75mm i/d Floor Trap (weighing 4.0 Kg)
29Providing and fixing in position automatic brass Ball Cock in tanks. (A) Plastic Ball Cock with rod and Plastic Ball (v) 50mm i/d
30Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. (i) Triple Layer Tanks
31Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. (a) G.I. tank nipple 15mm i/d
32Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) BClass including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. (a) 15mm i/d
33Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) BClass including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete.(b) 20 mm i/d
34RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mmdia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-(iii) Wiring light point
35(iv) Wiring 6Amp. wall socket point
36PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-(iii) Overall size 2.5sq.mm (Un-sheathed)
37Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). (c) Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 14Metre in length)
38MINIATURE CIRCUIT BREAKERS:(ii) MCB Single Pole 6-32amp. (10kA, Curve-C)
39SHEET METAL DOUBLE DOORDISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP CB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- (ii) SP&N Double Door Distribution Board 8 way each
40Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
41Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
42Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a ) UPVC 110 mm bend
43Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
44Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete. (a) Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
45Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iv )35mm thick
46Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
47Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
48Providing and fixing in position Sensor electric for urinal of approved make (to the approval of Engineer-in-charge) complete in all respect Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57214520
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 5.61 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Bhakra Beas Management Board
Work Description Tender for Nit For Construction Of Toilet At Premises Of Store And Transport Sub- Division, Bbmb (Pw), Slapper.
Basic Detail
Tender No 387/REDPH/BBMB
Bidding Type Tender
Location
City Mandi
State Himachal Pradesh
Key Dates
Publish Date 03 Sep 2026
Submission Date 09 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 5.61 Lakhs
Tender Fee Ref. Documents
EMD 11240
Exemption Not Available
Document List
00dc7652-d2db-4d24-90fe-fe2cda87c3f8.html
BOQ_337142.xls
NITDOCSTOPRETOILET.pdf
technicalstoretoilet.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

00dc7652-d2db-4d24-90fe-fe2cda87c3f8.html

xls

BOQ_337142.xls

pdf

NITDOCSTOPRETOILET.pdf

pdf

technicalstoretoilet.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders