BOQ
| Sl. No. | Item Description |
| 1 | Part D ( Alram, Smoke Detector, Fire Fighting & Extinguisher Work ) |
| 2 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. |
| 3 | 20 mm |
| 4 | Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H. |
| 5 | (A) End Suction / Horizontal Axially split casing volute type Single / Multi stage Centrifugal pump complete for delivery of below mentioned discharge and Head |
| 6 | (B) Material of construction : Pump Casing - PN-16,Cast Iron, Impellor - Bronze/SS-304, Shaft - SS 410, Packing - Mechanical Seal |
| 7 | (C)Pump shall be capable of delivering not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head |
| 8 | (D) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed 2900 / 1500 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (LoveJoy type) coupling , coupling guard complete in all respect . |
| 9 | ( E) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. |
| 10 | (F) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Physical presence of Department’s representatives. or by Third Party like RITES / PDIL / EIL |
| 11 | (G) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM |
| 12 | (H) Pumpset to be placed on Suitable size Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x 40mm x 5 mm ( Cost of RCC Foundation to be paid Extra See Chapter -23). |
| 13 | 1620 LPM suitable for 56 Mtr Head End Suction Back pull type Single Stage, 2900 RPM |
| 14 | Supplying, Installation, Testing & Commissioning of Diesel Engine Driven fire fighting duty pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H. |
| 15 | (A) End Suction / Horizontal Axially split casing volute type Single / Multi stage Centrifugal pump complete for delivery of below mentioned discharge and Head |
| 16 | (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal |
| 17 | (C)Pump shall be capable of delivering not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head |
| 18 | (D) Heat Exchanger cooled Diesel Engine as per NFPA 20 developing suitable BHP for the below mentioned discharge at 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter upto 10 M length (with LRB insulation & Alum. Cladding), with muffler, Diesel tank of 300 Lts capacity (made out from 2 mm thick MS sheet with filling Cap) with drain cock, Diesel level Indicator, Suitable MS angle iron stand for placing tank, first Filling of Diesel tank. |
| 19 | (E) Diesel Engine Control panel comprising Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication, Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter, |
| 20 | (F) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Physical presence of Department’s representatives. or by Third Party like RITES / PDIL / EIL |
| 21 | (G) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM |
| 22 | (H) Pumpset to be placed on Suitable size Existing Reinforced cement concreat (M-30) foundation with foundation bolt, Nosing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra See Chapter -23) |
| 23 | 1620 LPM suitable for 56 Mtr Head End Suction Back pull type Single Stage 2400 RPM |
| 24 | Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty Jockey pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM suitable for automatic operation and consisting of following details given as A, B, C, D, E,F and G |
| 25 | (A) Horizontal End suction Single / Multi Stage Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head |
| 26 | (B) Material of construction : Pump Casing - PN-16,Cast Iron, Impellor - Bronze/SS-304, Shaft - SS 410, Packing - Mechanical Seal |
| 27 | (C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 2900 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Lovejoy type) coupling , coupling guard complete in all respect . |
| 28 | (D) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. |
| 29 | (E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Physical presence of Department’s representatives. or by Third Party like RITES / PDIL / EIL |
| 30 | (F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM |
| 31 | (G) Pumpset to be placed on Suitable size Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra see chapter - 23 ) |
| 32 | 180 LPM suitable for 88 Mtr Single Stage |
| 33 | Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty Terrace pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H |
| 34 | (A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head |
| 35 | (B) Material of construction : Pump Casing - PN-16,Cast Iron, Impellor - Bronze/SS-304, Shaft - SS 410, Packing - Mechanical Seal |
| 36 | (C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (LoveJoy type) coupling , coupling guard complete in all respect . |
| 37 | (D) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. |
| 38 | (E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives. |
| 39 | (F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted from OEM |
| 40 | (G) Suitable rating DOL Starter with outdoor application as per Type-2 Coordination including Ammeter, Voltmeter, Indicating Lamps, including suitable control wiring for pressure switch as required. |
| 41 | (H) Pumpset to be placed on Suitable size Reinforced cement concreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra see chapter -23 ) |
| 42 | 450 LPM with 35 mtr head |
| 43 | Supplying, Installation, Testing & Commissioning of submersible type dewatering pump of stainless steel casing and Cast iron impellor of discharge and head given below complete with all accessories suitable for operation on 230 V, single phase/415 V /3 phase, 50 Hz. AC supply complete with starter for automatic operation including water level sensing device / float switch inter connection with submersible cable etc. as required. |
| 44 | 180 LPM with 10 mtr head |
| 45 | SITC of pressure switches of pressure range 3 to 15 Bar for Main, Jockey, Terrace pump and Diesel pumps, Etc. as Required ( Control Cable from Pressure switch to Panel to be Paid Extra ). |
| 46 | Providing and fixing 20/25 mm dia. (PN - 1.6, Type-S1, Flanged, ISI marked) air release valve confirming to IS - 14845 : 2000 with Double Flange isolating valve (pressure rating PN 1.6) complete with 1 no. Matching Flanges (Minimum 10 mm thick), nuts, bolts, washers, gaskets etc as required. |
| 47 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick walls and making good the same. complete with painting of one coat of Red Oxide and two or more coat of synthetic enamel paint of Signal red shade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). |
| 48 | 25 mm dia |
| 49 | 32 mm dia |
| 50 | 40 mm dia |
| 51 | 50 mm dia |
| 52 | 100 mm dia |
| 53 | 150 mm dia |
| 54 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C' class (Heavy) pipe conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications in Existing trench with cement concrete block as supports including cutting, welding etc & forged steel fittings like elbows, tees, tapers, reducer with cleaning,wrapping and coating of the pipe with 4 mm thick tar based polymaric corrosion protection tape including applying uniform coat of cold pipekot primer as per IS; 10221 for protection against corrosion complete in all respect. ( Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs. & Excavation of Trench and refilling of trench to be paid extra). |
| 55 | 150 mm dia |
| 56 | Supplying and fixing cylindrical air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with flanged connection, Provision for 25 mm dia drain valve,air release valve, safety valve pressure gauge as required accessories and painting with two coats of Red Oxide and two coat of Signal red enamel paint including the tank installed on suitable vertical legs. The legs shall be provided with M.S. Angle of size 75 mm x 75 mm x 5 mm at the bottom. The legs shall be grouted in cement concrete foundation. as required. ( Air Release valve, Drain valve, PRV, Pressure Gauge shall be Paid Extra ). |
| 57 | Supplying and fixing cylindrical air vessel of continuous welded construction fixed at riser top made of 250 mm dia, fabricated out of 8 mm thick MS sheet, 1200 mm in height with flanged connection, Provision for 25 mm dia drain valve,air release valve,safety valve pressure gauge as required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint including The tank installed on suitable vertical legs. The legs shall be provided with M.S. Angle of size 75 mm x 75 mm x 5 mm at the bottom. The legs shall be grouted in cement concrete foundation. as required. ( Air Release valve, Drain valve, PRV, Pressure Gauge shall be Paid Extra ). |
| 58 | Supplying and Fixing of PN 16 Flanged Y strainer fabricated out of cast iron body, SS 304 strainer with perforated screen with 3 mm. dia holes in existing MS / GI pipe complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets etc as required of following sizes. |
| 59 | 150 mm dia |
| 60 | Supplying and Fixing of PN 16 Flanged sluice valve with non rising spindle, bronze /gun metal seat confirming to IS:14846 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. |
| 61 | 100 mm dia |
| 62 | Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. |
| 63 | 80 mm dia |
| 64 | 100 mm dia |
| 65 | Supplying and Fixing of PN 16 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. |
| 66 | 100 mm dia |
| 67 | 150 mm dia |
| 68 | Supplying and Fixing of PN 16 Brass/GM Ball valves with screwed end, SS Ball including teflon tape etc. as required. |
| 69 | 25 mm dia. |
| 70 | 50 mm dia |
| 71 | Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A) 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304 male and female couplings (IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required. |
| 72 | Supplying & fixing SS-304 Short Branch Pipe conforming to IS: 903:93 fitted with 20mm (nominal internal diameter) bore nozzle, for projecting water in form of solid jet. The Branch pipe shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. |
| 73 | Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with up to date amendments, complete with the following as required. (A) Rubber Hose (B)20 mm dia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipment on wall. (D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1 through Forged steel Screwed Union & M.S. pipe. Etc. as required. With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:444 Type-2 and Bursting pressure min. 30 Kg/sqcm |
| 74 | With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969 and Bursting pressure min. 42 Kg/sqcm |
| 75 | Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valve complete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Ways. |
| 76 | 4 Way |
| 77 | Providing and fixing of 150 mm Dia. Flanged Gun Metal Fire brigade Suction hose coupling (draw out connection) for female coupling as per IS:902-1974 complete with Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required. |
| 78 | Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.2 mm thick MS sheet duly powder coated in red color externally and white internally with 6 mm thick glazed doors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) |
| 79 | Providing and Fixing of 15 mm dia Bronze quartzoid bulb type sprinkler heads with Maximum working pressure 11.6 Kg / Sqcm and suitable for 68 degree centigrade rating standard response (UL Listed) chrome plated complete in all respect of the following type. |
| 80 | Extended Throw Sidewall type . |
| 81 | Providing & fixing of UL listed 1.5 mm thick chrome plated Dual type MS Escutcheon plates fixed at junction of Sprinkler piping with the false ceiling. |
| 82 | Supply & Fixing of Fire Man's Axe with carbon steel head & rubber moulde handle usable upto 20 KV and confirming to IS :926 with length approx 0.4 M & weight min. 1.0 Kg. |
| 83 | Providing & fixing sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. |
| 84 | 700 mm Long |
| 85 | Providing & fixing Stainless Steel pressure gauge with dial of 150 mm dia size and range 0 to 20 kg/sq.cm with 3 / 8 \\" BSP bottom entry , Ball valve , SS Syphon tube all fittings etc, duly calibrated before installation in MKS and FPS units, Accuracy Level +/- 1% including Making Drilling in Existing MS Pipe Etc. as required. |
| 86 | Fabrication, Supply, Installation, testing and commissioning of IP-42 Electrical control panel of cubical construction, floor mounted type fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 9 tank treatment process, cable alley, Interconnection with suitable size copper conductor cable / solid alum. strip strip having switchgear and accessories, mountings and internal wiring, earth terminals numbering etc. complete in all respect for main fire pump, Jockey pump and diesel pump set complete with following incoming and outgoings suitable for operation on 415 V 3 phase |
| 87 | Incoming : 250 A, 50 kA, 4 pole MCCB, Ics = 100% Icu rating, Digital Voltmeter (0-500 V) with selector switch, Digital Ammeter (0-250A) with selector switch and CTs, LED type RYB Indicating lamp, ON, OFF Trip Indicating lamps, Aluminium TPN Busbar 400 Amps. |
| 88 | Outgoing Main Fire Pump: 125 A, 50 kA, 4 pole MCCB, Ics = 100% Icu rating, with suitable HP fully automatic DOL starter as per type-2 coordination with all accessories, internal wiring required for automatic operation, Digital Ammeter with selector switch and LED type ON, OFF Trip Indicating lamp, selector switch for local/remote, auto /manual/OFF operation - 1 Set |
| 89 | Outgoing Jockey Pump: 63 A, 50 kA, 4 pole MCCB, Ics = 100% Icu rating, with suitable HP fully automatic DOL starter as per type-2 coordination with all accessories, internal wiring required for automatic operation, Digital Ammeter with selector switch and LED type ON, OFF Trip Indicating lamp, selector switch for local/remote, auto /manual/OFF operation - 1 Set |
| 90 | Diesel Engine Control Panel : Comprising of Automatic / Manual selector switch and 3 attempts starting device, timers and relays as required push buttons, Start / Stop in Manual mode Indicating lamp for high / low lub. Oil pressure, High water temperature indication, Battery charger suitable for for 12V/ 24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, 0-20 A Dc ammeter, All standard accessories and relays for automatic operation of Engine |
| 91 | System controller : Designing, supply Installation testing and commissioning of system controller to control operation main Electrical fire pump, jockey pump, Terrace pump in sequence as per requirement, consisting of relays, timers sensors, annunciation window for fault indication complete as required. |
| 92 | SITC of UL 7th edition and FM certified photoelectric Analog addressable Smoke detector with mounting base & LED etc. as required. |
| 93 | SITC of UL 7th edition / FM certified Addessable Manual Call point (MCP) with LED / FIRE Indication Etc. as required. |
| 94 | SITC of UL 7th edition / FM certified Addressable Control (input/output) modules/ Relay / Monitor Module for shutting down lifts, control of Mechanical ventilation fans, Hooters, AHU's, Acknoledgement of Sprinkler system with potential free contact monitoring Etc. as required. |
| 95 | SITC of Response Indicator for indicating the activation of the Remotely located Detector for Addressable / Conventional type Detectors Etc. as required. |
| 96 | SITC of EN54 / VDS certified Microprocessor based intelligent, Analogue addressable,modular, Fire Alarm Control Panel with each loop capacity of 198 detectors/devices with minimum Loop length up to 1.2 KM and 500 mA loop power as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger, 24 AH 2 x 12V, SMF Lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, Touch screen display unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port( both RS485 & Ethernet), Serial port for printer, two supervisory inputs, two position key switch and USB port for programming.including the cost of all accessories Etc. as required. |
| 97 | 2 - Loop Panel |
| 98 | Loop expansion card |
| 99 | SITC of 2 way communication Fire Fighter's Telephone Jack.Complete as required . |
| 100 | SITC of 2 way communication Fire Fighter's Telephone Handset to make a call to the Main FACP from Telephone Jack Location Complete as required . |
| 101 | Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. |
| 102 | 2 x 1.5 Sq.mm Unarmoured With Outer Sheath in Red Color |
| 103 | SITC of power Amplifier with Amplifier topology of Class D >90% efficiency, 100V & 4-16 OHMS Transformer less design, output Short-Circuit & Thermal Protection CE Compliant with following wattage as required. |
| 104 | 240 Watt |
| 105 | SITC of 6W Ceiling Speaker with max SPL1M/1W 95dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W |
| 106 | SITC of 15W Horn Speaker (IP66) with max SPL1M/1W 115 dB . Frequency response of 350Hz-8KHz with a dispersion angle of 140 deg. The speaker shoud have tappings at 15W/7.5W |
| 107 | SITC of 30W Volume controller, 3/4 wire, ABS Material, with 24V Override Function |
| 108 | SITC of DVD with built-in USB, MP3, AM/FM player, Bluetooth v5, SD Card Music Player with necessary accessories. |
| 109 | Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required. |
| 110 | 1.0 Sq. mm |
| 111 | Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability, including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. |
| 112 | Capacity 4.5 Kg. |
| 113 | Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. |
| 114 | Supply & Fixing of Ceiling mounted UL listed clean Agent (HFC-236fa), Modular type Fire Extinguisher , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Fixed Bulb with Temerature 68 deg C, QR code for Product Traceability including Fixing on Ceiling with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated La+C3755b is to be submitted. |
| 115 | 5 Kg Capacity |
| 116 | Providing and fixing signages as per required content printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating with suitable colour combination (Glow in dark) with high intensity properties for indoor surface glow visibility not less than 6 hrs. in total darkness and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. |
| 117 | Single sided signage board |
| 118 | Providing and fixing of Aluminium housing body self contained Rechargeable LED Emergency Light with required content and Size Approx. 300 mm x 180 mm, confirming to IS:9583 :1981with Ni-Mh / Ni - Cd Battery, 3 Hrs Back Up, Constant Current Charger, Input Voltage 230 V , 50 Hz including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. |
| 119 | Single sided signage |
| 120 | SITC of 1Phase Input, 1Phase Output Microprocessor control based Inverter with input voltage range of 180-260V and output voltage same as input 210V +/- 10%, output frequency of 50 +/- 0.1 Hz and 0.8 Output factor. Overall efficiency of upto 80%, Transfer time 15 msec & Sinewave output.Inverter should have LED/LCD Panel Display showing Mains ON, INV. ON, Charging/Charged.Inverter should have protection from Overload/Short Circuit Trip/Over Temperature and Low Battery Trip.Batteries should be Tubular Type for 60 min back up with Trolley/Rack and necessary cable for Inverter to Batteries Installation. |
| 121 | 1KVA (1/1) Inverter with 1600 VAH Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender