Health and Family Welfare Boards / Undertakings / PSU Closing in 5 days TDR #57211780

Tender For Supply Installation Testing and Commissioning of Hvac Work In Store Building (G+1), Near Lmo Tank Area At Hbch&Rc, New Chandigarh Punjab 140901.

Issued by Boards / Undertakings / PSU · S.a.s Nagar, Punjab
Tender Value
12.55 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
5 days left
EMD
29640
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
S.a.s Nagar → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Hvac Work In Store Building (G+1), Near Lmo Tank Area At Hbch&Rc, New Chandigarh Punjab 140901.

BOQ

Name of Work:- SITC of HVAC work in Store Building (G+1), near LMO tank area at HBCH&RC, New Chandigarh Punjab 140901.
Sl. No. Item Description
1DUCTABLE TYPE SPLIT UNITS Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 230/415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L ,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electro-technical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. Non-Inverter, cooling mode only. Make: Blue star/York/Trane/Equivalent
25.5 TR (2200 CFM)(3.2 EER)(3W+ 1S)
3Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Package and Ductable system, complete with fittings, with suitable supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : Thicknees of copper pipe 1.2mm Make: Mandev/Totaline/Hariom
422.2 mm dia (OD) (Hard drawn) with 19 mm thick insulation
59.5 mm dia (OD) (Soft drawn) with 19 mm thick insulation
6Supply and charging of Additional gas for the entire length of copper tube -Refrigerant R410A Environmental friendly refrigerant
7Supply and Installation of following sizes of PVC/ UPVC Drain pipe with 6 mm thick nitrile rubber insulation with all accessories like Elbow bend, T , union , reducer etc is in vendors scope. Drain pipe to be installed for both indoor and outdoor unit ( separate drain pipes to be installed in all units. )
825 mm
932 mm
10Supplying, installation, balancing and commissioning of factory fabricated/site fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required. Make: Tata/ Jindal/Sail/AMNS
11Thickness 0.63 mm sheet
12Thickness 0.80 mm sheet
13Supply & fixing of powder coated extruded aluminium Supply Air Grills with collar damper. Make: Airflow/Systemair/Uniaire/CARRYAIRE
14Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.
15Supply and making end termination of following sizes of armoured copper power cable for outdoor units.Make: Havells/Polycab/KIE
164C X 6 SQMM - Cu
17Supply and making end termination of following sizes of flexible control cable.Havells/Polycab/KIE
186C X 1.5 SQMM
19Supply and fixing of following earthing materials.
206 SWG Dia GI Wire
21Cable TraysSupply and installing of following size of (Hot dip) GI Perforated type cable trays (Galvanisationthickness not less than 50 micron) with perforation not more than 17.5% in convenient sections, joined with connectors including GI bolts & GI nuts including fabrication, etc.
22150 mm width X 50 mm depth X 1.6 mm thickness
23Supply and Installation of MS Stand/Hanging arrangement for Outdoor & Indoor units for Ductable Ac.
24Electrical Work:SITC Of Outdoor type wall mounted type electrical panels including system control wiring with Incoming, outgoing feeders as described below :
25a. 160 - 165 A TPN MCCB as a incomerb. RYB LED type indication llghts --01 Setc. Multifunstion meter-1 nos.d. 20 Amp 4 Pole C Curve MCB for outgoing-12 Nos. (spare-2MCB)
26Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall 1.5 TR split type Air conditioners working on cooling mode, complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature) Make: Blue star/York/Trane/ Equivalent
27Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
28Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57211780
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 12.55 Lakhs
LAST DATE 19-09-2026
Authority
Authority Name Tata Memorial Centre
Work Description Tender for Supply Installation Testing and Commissioning of Hvac Work In Store Building (G+1), Near Lmo Tank Area At Hbch&Rc, New Chandigarh Punjab 140901.
Basic Detail
Tender No HVAC -STORE BUILDING/2026-27/33
Bidding Type Tender
Location
City S.a.s Nagar
State Punjab
Key Dates
Publish Date 26 Aug 2026
Submission Date 19 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 12.55 Lakhs
Tender Fee Ref. Documents
EMD 29640
Exemption Not Available
Document List
BOQ_970708.xls
e95d227e-b681-4f6c-a359-9528945ba9e2.html
technicalchecklist.xls
Tendernotice_1.pdf
undertakings.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_970708.xls

html

e95d227e-b681-4f6c-a359-9528945ba9e2.html

xls

technicalchecklist.xls

pdf

Tendernotice_1.pdf

pdf

undertakings.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders