Tender For Dnit For The Work Improve The Quality Of Treated Effluent Discharge And Promote The Recycling Of Treated Water Of Stp 7.50 Mld Narnaul Under Jal Hi Amrit Program And All Other Works Contingent Thereto.App. Cost Rs. 60.65 Lacs
Tender Overview
Project Description
Tender for Dnit For The Work Improve The Quality Of Treated Effluent Discharge And Promote The Recycling Of Treated Water Of Stp 7.50 Mld Narnaul Under Jal Hi Amrit Program And All Other Works Contingent Thereto.App. Cost Rs. 60.65 Lacs
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Safety Equipments- 3 Oxygen Cylinders-3 Kg Portable Type, 8 Safety Belts, 8 Helmets, 8 Set of Safety Shoes, 5 Fire Extinguishers-2Kg Each, Oxidised Saftey Chain-50m, Rope 25 mm 100m, 8 Set of Satey goggles and gloves, Safety Jackets-15, PPE Kit-3 |
| 2 | -Supply, Erection, Installation, Testing andCommissioning of Laboratory Equipment , Chemicals andGlass ware as per Annexure-AChemicals:Cons. Sulfuric Acid2.5Ltr,Manganese Sulfate (MnSO4.H2O) 500gm,Sodiumhydroxide (NaOH) 500g, Sodium Iodide (NaI) 500g, SodiumAzide (NaN3) 500g, Starch 500g, Salicylic Acid 500g, SodiumThiosulfate 500g, Potassium Dichromate ( K2Cr2O7) 500g,Silver sulfate (Ag2SO4) 100g,Ferouss Ammonium sulfate(NH4)2Fe(SO4).6 H2O 500g, Ferroin Indicator 125ml,Filterpapers 1 Pack, Hydrochloric Acid HCL 2.5ltr, Iodine 500g,Potassium Iodide500g, Magnesium Chloride MgCl2.6H2O500gm, Sodium Acetate 500ml, PotassiumNitrate500gm,Acetic Acid 2.5ltr, Methyl orange indicator 125ml Instrumentation: COD Digester with Closed Reflux method,controlled by solid state digital temprature, Indicator cumcontroller (Microprocessor based, Digital pH meter, Turbiditymeter, Spectrophotometer- UV double beam Microprocessorbased, To measure 9 wavelengths and 2 samples at a time,Oven Incubator minimum size 450 mm x 450 mm x 600mm,BOD Incubator- Volume 113 litres minimum with solid stateelectronic digital model, Digital balance- 200 gm weighingcapacity with 0.1 mg accuracy, Muffle Furnace rectangularwith Muffle size (125 mm x 125mm x 250mm), DissolvedOxygen meterwith LCD Display, Binocular Microscope withLED light source, Deep Freezer- Capacity 4 Cu Ft, MagneticStirrer with capacity of hot plate as 5 litres, Double DistillationApparatus - electrically heated, 5 litre capacity, BacteriologicalOrbital Shaking Incubator temperature range from ambient to70 degree celcius, able to accomodate 16 flasks minimum,Biological Safety Cabinet/ sampling Booth- working size-4`x 2`x 2`, Fume Hood- working size 4` x 2` x 2` , Vaccum Pump(Mono block, beltless) moisture trap and vaccum GaugeCapacity -75 litres, Autoclave Vertica- Size 400mm x 600 mmCapacity 98 litresGlass Ware :Desiccator 12’’,1 No, Crucible 50ml,12 Nos,Conical Flask 500 ml 12 nos. Conical Flask 250 ml 12 nos.Measuring cylinder 100 ml 6 nos.Measuring cylinder 50 ml 6nos., Measuring cylinder 10 ml 6 nos.,Volumetric Flask 100 ml6nos., Volumetric Flask 500 ml 6 nos.,Volumetric Flask 250 ml6 nos,Volumetric Flask 100 ml 6 no, Volumetric Flask 50 ml 6nos, Petri diss 4’’, 12 Nos, Burette with stand 500ml, 12 Nos,Micro Pipette 5 ml and 10 ml 6. Nos, Dispenser bottle400ml, 6 Bottles, Distilled water collection bottle 5L(2 Nos),BODBottles, 300 ml-27 Nos, Beaker 10ml,250ml 500ml 1000ml2000 ml (4 Nos Each), Test tube, 1 Box |
| 3 | Open Channel Flow Meter (Ultrasonic type, suitable for 1 m wide bypass channel, 7.50 MLD) Including all the requirements. Accuracy: ±1% of flow, Non-contact sensor, IP-68, Digital outputs (RS- 85/Modbus). of approved make in NIT. |
| 4 | COMMON DATALOGGER: Compatible Industrial Datalogger for flow meters. Must support Quad-core processor, =4 GB RAM, =32 GB SSD/eMMC: Linux OS: =2 RS-485, Ethernet, Wi-Fi, HDMI: IP65 enclosure: UPS =2 hrs.Large Display: 32” wall mountableAdvanced Alarm and Notification Engine: SMS/email alerts, escalation matrixInteractive Map Dashboard: GIS view: green/yellow/red status. Bidder mustprovide its own secure dashboard platform (not third-party hosted) to ensure datasecurity and compliance. Custom Report Generator: Auto PDF/Excel reports: CPCB/HSPCB format. Role based Multi-User Access: Operator/supervisor/admin roles: audit trail. All accessshall be through bidder’s proprietary dashboard, ensuring secure data segregation.Dashboard shall be hosted on bidder’s own secure infrastructure. Customizable Widgets and Dashboards: =35 widget types: drag-and-drop. Bidder’s own secure dashboard solution is mandatory. API Integration Module: JSON/HTTPS push to CPCB/HSPCB servers. APIs must originate from bidder’s dashboardplatform with full data control.Cloud-Based Datalogging Backend: Minimum Tier-III VPS: Ubuntu Linux (latest LTS):=8 vCPU, =32 GB RAM, =400 GB SSD: Dedicated IPv4: secure HTTPS access: dailybackup. Cloud backend must be hosted and managed by the bidder to ensurecomplete data ownership and security. Fail-Safe Data Storage: Local storage (=32 GB SSD/eMMC) with auto re-sync tocloud/dashboard once connectivity restores. Must be integrated in bidder’sproprietary dashboard.Edge Data Processing: Local pre-processing (averaging,filtering, anomaly detection) before sending to cloud/dashboard. All features mustbe integrated into bidder’s own dashboard platform.Custom Rule Engine: If/then logic for alarms and controls. Must be part of bidder’ssecure dashboard. Dual Communication Redundancy: Ethernet plus Wi-Fi plus Dual SIMfailover. Shall be provisioned within bidder’s dashboard eco-system. Multi-Tenant Architecture: Multiple sites under secure accounts. Architecture tobe managed within bidder’s dashboard solution.Historical Data Explorer: Graphswith zoom/compare/overlay. Feature to be included in bidder’s dashboard. complete in all respect as per specification and makes as defined in approved NIT. |
| 5 | HSR Items Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender