Tender For Provision Of Certain Sanctioned Works (E/M) At 15 Repair Renovation (14 Gr) At Bb Cantt, Srinagar.
Tender Value
46.10 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
14 days left
EMD
92200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of Certain Sanctioned Works (E/M) At 15 Repair Renovation (14 Gr) At Bb Cantt, Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, commissioning of Metal Top Deep Freezer capcity 405/425 Litre, single phase 240 volt, 50 Hz, complete all as specified and directed. |
| 2 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltag stabilized at 230 V with accuracy of -2.5% to + 2.5 % and capacity of 4KVA, complete all as specified and directed. |
| 3 | S&F sub main wiring with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire single core of size 2 runs of 4 Sqmm and 1 run of 4Sqmm (Nominal area) (ISI Marked) any type any length drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed in wall or surface on wall and making good all disturbed surfaces match to the existing surface, complete all as specified and directed.Note: 3 runs of 4 sqmm cable and one run of conduit/ casing capping shall be measured and paid as one unit. |
| 4 | Supply and fixing of sheet metal enclosure duly powder coated with double pole and neural enclosure with a two pin and earth plug and top and having mounting chanel and complete with one 01 MCB SP 20 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed on wall and making good the disturbed wall surface all as required at site, complete all as specified and directed. |
| 5 | Supply, laying and testing PVC insulated, PVC Sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy) with stranded copper conductor of size 3 core, 2.5 sq mm,1100 volts grade, complete all as specified and directed. |
| 6 | Supply, Installation, Testing & Commissioning (SITC) of 360 Litre Double Door Refrigerator, 230V AC, Single Phase, 50Hz, 5-Star Energy Rating, complete with compressor, shelves, door lock, internal light and all standard accessories as required, complete all as specified and directed. |
| 7 | Supply, laying and testing XLPE insulated, PVC sheathed, conforming to relevant IS, ISI marked, earthed system, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, in trenches/wall/floor/pole complete and making connection including suitable size Aluminium lugs, complete all as specified and directed for the following cross sectional area of cable :- |
| 8 | 25 Sqmm, 4 core |
| 9 | 16 Sqmm, 4 core |
| 10 | 10 Sqmm, 4 core |
| 11 | 16 Sqmm, 2 core |
| 12 | 10 Sqmm, 2 core |
| 13 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of under ground cables, pipes etc. and getting out all excavated material in any soft/loose soil, complete all as specified and directed. |
| 14 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. |
| 15 | Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed. |
| 16 | M&L for locally available river sand in trenches 15 cm below cable and 8cm above / around UG cable for cable protection, in duct under and above the cables including punning around cable, complete all as specified and directed.Note: - Punned thickness shall only be measured and paid. |
| 17 | Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise, complete all as specified and directed. |
| 18 | M & L for Aluminium busbar 150 Amp capacity, 415 volt colour code with neutral including 100 Amp MCCB three phase and netural with encloser including indication lamp, Angle iron leg and PCC foundation, complete all as specified and directed. |
| 19 | M & L for Aluminium busbar 100 Amp capacity, 415 volt colour code with neutral including 63 Amp MCCB three phase and netural with encloser including indication lamp, Angle iron leg and PCC foundation, complete all as specified and directed. |
| 20 | Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 32x6mm size GI strip as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and directed. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. |
| 21 | S&F galvanised steel tubing, light grade of sizes 50 mm bore ISI marked, for protection of under ground cable on pole/wall/under road , complete all as specified and directed. |
| 22 | S&F galvanised steel tubing, light grade of sizes 40 mm bore ISI marked, for protection of under ground cable on pole/wall/under road, complete all as specified and directed. |
| 23 | Material and labour for road cutting of minimum sizes 30cm x 30cm and minimum width of 3 mtrs for laying cables etc upto 10 mtr and making good the disturbed surface to match existing surface using plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate), complete all as specified and directed. |
| 24 | Supply and laying HDPE DWC Pipe outer dia 90/76 mm. for protection and covering the XLPE cable complete all as specified and directed. |
| 25 | Supply and fixing of rigid non metalic PVC conduit of size 15/20 mm bore heavy duty with all fitting laid in trenches/ wall including providing clamping arrangment for holding of pipe on wall in proper size of clamps, nut bolt ,and washer etc., complete all as specified.and directed |
| 26 | S&F LT cable route indicator, engraved the description on the disc not less than 6\\" dia welded with 40 x 6 mm MS Strip of approximate length 90 cm duly painted on all steel parts as per colour code and provision of PCC (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) of not less than 0.05 cum in each at base buried under the ground including necessary earth work, including taking down old cable route indicator, complete all as specified and directed. |
| 27 | Supply and Erecting in vertical position steel tubular swaged pole type 410 SP-31 (9 metre long) with 300mmx300mm x6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enamelled paint up to 1.5M from ground level/coping complete all as specified and directed.Note:- Earthwork and concrete shall be measured and paid saparatly under respective items. |
| 28 | Material and labour for plain Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concrete including necessary steel form work and finishing the surface fair in forms for poles etc, complete all as specified and directed. |
| 29 | Material and labour for plain Cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concrete including necessary steel form work and finishing the surface fair in forms for poles etc, complete all as specified and directed. |
| 30 | Supply, Installation, Testing and Commissioning of LED Street light Fitting with a nominal system 5300 lumen output of lumens, minimum system efficacy of 115 lm/W and total power consumption not exceeding 60 W (including driver). The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a color temperature of 5700 - 6500K and CRI>80. The luminaire shall meet IP66/IK07 or IK08 rating with THD<10% and PF > 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The driver should have phase to phase protection for 8 hours. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate \\"R\\" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole, complete all as specified and directed |
| 31 | M & L for bracket made out of GI tubing 40 mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 40 mm wide 4 mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -4 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc., complete all as specified and directed at site. |
| 32 | Supply & fixing Thermo plastic street light sintex box of size 280 X 170 X 120 mm fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box all as specified and directed |
| 33 | Supplying and fixing flexible type round PVC bedded with PVC insulated and sheathed with multi FRLS cable of 1100 volt grade with multistranded copper conductor wire of size 1.5 Sq.mm 3 core type (Nominal area) ISI Marked, complete all as specified and as directed |
| 34 | Automatic street light switch using NATURE SWITCH for automatic switching of street Lights based on LUX level of Natural Light. The sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/ wall mountable enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54 degree of ingress. The contactor, MCB and Circuit wiring should suitable enough to take load of 1 KW MCB (single-pole) Rating :32 Amps 3 Nos, complete all as specified and directed. |
| 35 | S&F HT/LT cable route indicator, engraved the description on the disc not less than 6\\" dia welded with 40 x 6 mm MS Strip of approximate length 90 cm duly painted on all steel parts as per colour code and provision of PCC (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) of not less than 0.05 cum in each at base buried under the ground including necessary earth work, including taking down old cable route indicator, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender