Tender For Solar Water Treatment Plant And Drinking Water: 1 Hp Solar Water Pump, Sp Module: 1200 Wp. Module Mounting Structure: Set Controller: 1 No, 1 Hp Submersible Water Pump With Pipe-1 Set, Water Storage Tank-Capacity 3000 Ltr.:2 Nos. Cable & A
Tender Overview
Project Description
Tender for Solar Water Treatment Plant And Drinking Water: 1 Hp Solar Water Pump, Sp Module: 1200 Wp. Module Mounting Structure: Set Controller: 1 No, 1 Hp Submersible Water Pump With Pipe-1 Set, Water Storage Tank-Capacity 3000 Ltr.:2 Nos. Cable & Accessories: 1 Set, Tap 4 Nos. Including Boring 250 To 300 Ft. At Toldih Village, Po- Rukni Under Natundih Gp, Jl No- 51, Plot No 165 Under Raghunathpur-Ii Panchayat Samity In The Purulia District.
BOQ
| Sl. No. | Item Description |
| 1 | Drilling a bore hole in DTH process through any kind of soils and rocks in overburden suitable for lowering and fitting fixing of 200 mm internal 1 dia. casing pipe (casing pipe will be supplied by agency) upto an average depth of 25 mtrs. and subsequently 165 mm dia intr boring through any kind of rocky formation upto a total depth af 170 mtrs (for dry drilling or sufficient water not achived, driIling may be continued upto 200 mtr ) including all other works necessary for boring and lowering fitting fixing of MSERW/UPVC casing pipes suitable for 165 mm dia drilling In rock bed and grouting the same as per direction of the E.I.C including (in case of MSERW casing pipes) the cost of weilding of MSERW casing pipes and welding the top of the casing pipe with one 8mm thick MS cover plate (with supply and delivery of the plate). Necessary arrangement to be made for proper secuirity of bore hole.(a) 0 to 25 mtr |
| 2 | (b) 25 mtr to 170 mtrs and above |
| 3 | Supply & delivery of UPVC Casing pipe (CM) conforming to IS 12818:2010 (CIPET certified) a)200 mm dia |
| 4 | Supplying, installation and lowering in position solar Panel based AC Subrmersible pumping machinery (Preferably with stainless steel fabricated components) with solar cable & cable connector kit, PV Panel (IEC 61215:2015 certified), Controller, Overhead protection, Dry run protection, Auto Restart facility, Float switch with water level sensors, software for start-up of motors, making necessary connections with supplying G.I.Controller box and supplying 32mm dia PVC column pipe 42m length including earthing etc.as per direction of the EIC.i.) Solar Panel Canfiguration:4 panels of 325 Wp (72 cell) each (solar Panel to be installed on top of M.S. Supporting structure);ii) Submcrible pump capaity 1.00 HP, 14 Stage, 32mm outlet dia (preferably oil filled) KSB/ Crompton or renowned brand and including Operation and maintenance of entire installations for 5 years (except day to day operation) which includes: a) Cleaning of site, checking of valves and pipes, checking of electrical connections, cleaning solar panel etc Twice in a month;b) Replacement of damaged Valves, Bib cocks and any other parts of all units and when necessary, c) Repair/Replacement of pumping machinery i.e controller, pv panel, wiring, switches etc and when necessary.d) painting of m.s. structure and all painted surface at the end of each year. |
| 5 | Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part-I ). With all necessary accessories, specials viz socket, bend, tee, union, cross, elbo, nipple, Iong screw, reducing Socket, reducing tee, short piece etc. fitted including cost of all materials jointing materials, cutting pipes, making threads, cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed comlete in all respect. (Paymet wiil be made on the centre line meaurement of the total pipe line will be made on he Centre line measurement of the total pipeline including all specials No separate pavment will be made for aceessories.specials)i. 32 mm dia |
| 6 | ii. 25 mm dia |
| 7 | iii. 15 mm dia |
| 8 | iv. 40 mm dia |
| 9 | v. 50 mm dia |
| 10 | Laying Rising main, delivery main, Over flow, wash out pipe line with supplying fitting and fixing PVC pipes of approved make (Medlum duty) conforming to ASTMD-1785 schedule-80 and threaded to match with Gl pipes as per IS: 1239 (Part-1) with all necessary accessories, specials, viz socket, bend.tee.unlon, cross, elbow', nipple, longscrew.reducing socket, reducing tee.short plece etc, fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground to feed the water nearest to houses at least one habitation to get water through stand post and complete the all works as per drawing & direction ofthe E.I.C. (Suggested brand: Supreme/ Ori plast/ long last (Payment will be made on the centre line measurement of the total pipe line including all specials. No seperate payment will be made for accessaries. 50 mm PVC (ASTMD) |
| 11 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement any, in ground floor as per relevant IS codes.) lead upto 50km from Barabazar quarry site (barabazar varirty) |
| 12 | Supplying and erecting in postion Mild4 Steel (as per IS808 and other relevent code) Supporting structure, M.S plate (3.55 mm thick) at top platform (2.1 mx2.1 m), including M.S. Ladder (Suitably placed), for supporting PVC Tanks (Including supply of 5000 Itrs.capacity PVC/HDPE tank of approved quality with closed top with lid (Black) Multy layers as shown in the drawing) and Solar Panel, all necessary pipeline connections with all PVC pipes from Tubewell to delivery, specials, valves all complete as per approved drawing; and specification and direction of Engineer In charge (minimum weight 1080 kg) Reinforcement should be Tor Steel/ Mild Steel/ SAIL/TATA/RINL |
| 13 | Construction of RCC stand post (900 mm height) of RCC (1:1.5:3) footing over 75 mm thick 4:2:1 P.C.Cover a single B/F soling with 1%f reinforcement, connected withsaddle piece & 15mm dia brass ferrule with supplying fitting fixing 15mm dia, G.l.socket, G.1.200mm x 150 mm reducing elbow and 20 mm dia Glin) TATA pipe of(avg.) 2.6 mtr. long and onel 5 mm dia alloy Iron with brass spindle bib cock with socket and 20mm G.I elbow 2noss with 15mm Cl(m)TATA pipe of 0.225mtr. for connection of stand post to distribution line as per deptt design and drawing as per direction of EIC along with Construction of platform of size CC platform (1:2:4) over a single B/F soling below G.L over 150mm. thick sand filling, neat cement finish over [platform and Inner side of band and 15mm thick cement plaster (4:1) on top of platform banes and outside upto G.Las per deptt. drawing and as per direction of EIC |
| 14 | Supplying, fitting, finxing, Chain link (75 mm. x 75 mm. x 8 g) fencing of approved quality with iron posts by means of welding arround the Solar Pannels platform by supplying, fitting, fixing galvenized on MS angle of approved quality which grouted on the earth by cement concreting as per drawing Including an arrangement and provision of a gate with lock & key facility should be provided as per necessary direction of the E.I.C. Total length of fencing 15.4 rmt (Height 2.30mtr.) Note: Deduction Rs. 1572.00 will be made for each meter for less execution. |
| 15 | Sub Total |
| 16 | GST 18% |
| 17 | CESS 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender