Tender For Supply & Installation Of Led Street Lights At Kona Purbapara Janakalyan Samity, Kona Bhootbagan Kathpole, Kona Purbapara Baro Babar Mandir To Sujay Nahas House, Kona Tetultala Baidyanath Roy Sarani & Kona Purbapara Sasantala Kali Mandir Un
Tender Overview
Project Description
Tender for Supply & Installation Of Led Street Lights At Kona Purbapara Janakalyan Samity, Kona Bhootbagan Kathpole, Kona Purbapara Baro Babar Mandir To Sujay Nahas House, Kona Tetultala Baidyanath Roy Sarani & Kona Purbapara Sasantala Kali Mandir Under Ward No.50 And 1 No. High Mast Light At Kalitala Arupara Crossing Near Howrah Hindi University Under Ward No.49 Of H.M.C.
BOQ
| Sl. No. | Item Description |
| 1 | Erection of single steel Tubular pole of length as given below with /without sole plate & cap etc. in C.C. foundation (Proportion and dimension indicated below). having 600 x 600 x 150 mm. thick C.C. (4:2:1) base block below sole plate/pole with hard jhama metal incl. C.C (6:3:1) muffing 0.30 Mt.dia and 0.30 Mt above ground level incl.3mm thick neat cemented finished and G.I. earth bolt after making drilled holes etc.on pole & Carriage of pole upto 1.6 Km from store to work site incl. filling up the excavated earth pit with shifted soil and ramming properly. Pole upto 9 Mts. Size- 0.6 x 0.6 x 1.70 Mts. Ref: PWD/Elec.works/2017/P-H-1/I-1 |
| 2 | Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. Ref: PWD/Elec.works/2017/P-C-3/I-20(a) |
| 3 | Distribution wiring for street light on pole for outdoor fluorescent / SV / MV light fitting with 2 x 1 / 1.40 PVC insulated and sheathed wire (single core) in 15 mm dia GI pipe (ISI-Medium) without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI pipe bracket of length 1.05 mts., on pole incl. S&F suitable MS flat clamps with bolts, nuts etc. as required and painting. Ref: PWD/Elec.works/2017/P-H-5/I-H(2) |
| 4 | Supplying & fixing GI waterproof type looping cable box size 200 x 150 x 100mm deep having 4mm thick comprising of one 250Volts 15 A Kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2 core 16 sqmm PVC/A cable and having lined with rubber gasketted CI top cover with brass machine screws etc. earthing terminal with lug,on steel tubular pole near base, incl. S & F 40 x 6 mm thick, MS clamps with bolts, nuts etc.incl.painting with anticorrosive paint. Ref: PWD/Elec.works/2017/P-H-5/I-H(5) |
| 5 | Painting of steel tubular pole of length and no.of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl.prepartion of surface by sand paper/emery paper,cleaning etc.for receiving fresh coat of paint upto 9 Mts. long pole:- 2 coats of Aluminium Paint over 1(one) coat of R.O.priming. Ref: PWD/Elec.works/2017/P-H-2/I-4 |
| 6 | Painting Block Letters or Digits within a circle/square as required, with \\"Black Japan\\" paint of approved make & brand, the size of letters and digits as given below: Size 50 mm and upto75 mm. Ref: PWD/Elec.works/2017/P-H-2/I-6(b) |
| 7 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (hot Dip) wire (4 Mts.long), 13 mm dia x 80 mm long GI bolts, double nuts,double washers incl. S&F 15 mm dia GI pipe protection (1 Mt.long)to be filled with bitumen partly under the ground level and partly above groung level driven to an average depth of 3.65 Mts.below the ground level. By ISI-Medium G.I Pipe. Ref: PWD/Elec.works/2017/P-G-1/I-2(a) |
| 8 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (hot Dip) wire (4 Mts.long), 13 mm dia x 80 mm long GI bolts, double nuts,double washers incl. S&F 15 mm dia GI pipe protection (1 Mt.long)to be filled with bitumen partly under the ground level and partly above groung level driven to an average depth of 3.65 Mts.below the ground level. By ISI-Medium G.I Pipe. Ref: PWD Elec Works 2017 |
| 9 | Supplying & fixing 50 mm heavy gauge Polythene Pipe protection with necessary fittings & jointing materials as required. Ref: PWD/Elec.works/2017/P-K-2/I-55 |
| 10 | Supply of Al.Conductor PVC insulated and sheathed unarmoured cable (1.1 KV grade, Gloster/Havells/Polycab). 2 Core x 10 mm.2. Ref: UDMA/Elec.-Mech.works/2018/P-13/I-3© |
| 11 | Supply of Al.Conductor PVC insulated and sheathed unarmoured cable (1.1 KV grade, Gloster/Havells/Polycab). 4 Core x 10 mm.2. Ref: UDMA/Elec.-Mech.works/2018/P-13/I-3© |
| 12 | Supplying & Erection of 75 x 88 mm Porcelain Shackle insulator complete with 190 x 30 x 5 mm Galv.(Hot Dip) Strips with 15.88mm dia Galv. bolts, nuts, etc. for conductor upto 7/3.10 mm, 32 sqmm of AAC/equivalent size of ACSR. Ref: PWD/Elec.works/2017/P-H-3/I-D(1) |
| 13 | Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing & Drawing of unarmoured cable of suitable size (supply of cable is not included in the scope)on existing Galvanized stranded wire for centenary system with reel insulators and binding wires. Ref: UDMA/Elec.-Mech.works/2018/P-8/I-41&42 |
| 14 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following armoured cables (make: Polycab/ Gloster/Havells/): 4 Core x 16 mm2 Ref: UDMA/Elec.-Mech.works/2018/P-11/I-d(3). |
| 15 | Laying of one No.cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 Nos.bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, levelling up and restoring surface duly rammed. Ref: PWD/Elec.works/2017/P-F-2/I-1(a) |
| 16 | Supplying & fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: For 4 Core x 16 mm2 Ref: PWD/Elec.works/2017/P-F-4/I-7© |
| 17 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. FP 63A Make: L&T or equivalent. Ref: PWD/Elec.works/2017/P-D-6/I-7 |
| 18 | Supplying & Erection of big size feeder pillar box of Size (1372 x 914 x 607 mm) made up of 3.15 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box willbe painted by 2 coats of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35x35x3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5\\" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C. Ref: UDMA/Elec.-Mech.works/2018/P-7/I-40 |
| 19 | Supply and fixing of 240/230 volt, 50 Hz, T.P., power contactor (Make: L&T/ABB/ Schneider/Simence/GE) having contact block of the following range. Ref: UDMA/Elec.-Mech.works/2018/P-16/I-18(f) |
| 20 | Supply and delivery of Electronic Timer suitable for 240/ 360/415V, 50 Hz(Make: L&T/ABB/Schneider/Simence/GE/Minilic) of the following time (Second) range:12.0 to 120.0 Ref: UDMA/Elec.-Mech.works/2018/P-19/I-31(b) |
| 21 | Supplying of Swaged Steel Tubular pole(IS 2713,Pt. II 1980) for following designation and of following dimensions 4 SWG ;5.0 mtrs; 45 Kg Ref: UDMA/Elec.-Mech.works/2018/P-3/I-1(b),(d)&(j) |
| 22 | Supplying of Swaged Steel Tubular pole(IS 2713,Pt. II 1980) for following designation and of following dimensions 410-SP-1; 7.0 mtrs: 62.00Kg Ref: UDMA/Elec.-Mech.works/2018/P-3/I-1(b),(d)&(j) |
| 23 | Supplying of Swaged Steel Tubular pole(IS 2713,Pt. II 1980) for following designation and of following dimensions 410-SP-33; 9.0mtrs: 164 Kg Ref: UDMA/Elec.-Mech.works/2018/P-3/I-1(b),(d)&(j) |
| 24 | Supplying & wiring in 6.0 sqmm 'FR' stranded Copper wire single core inside feeder piller box as per direction of E.I.C. Ref: PWD/Elec.works/2017/P-K-2/Sl No.-73 |
| 25 | Hoisting fixing and commissioning of luminaries including making necessary connection and earthing attachment: Ref: UDMA/Elec.-Mech.works/2018/P-35/I-7 |
| 26 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRIEMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). >70, under voltage and over voltage protection, Type: 200 Watt LED or equivalent Ref: DELHI SCHEDULE OF RATES (E&M)-2025/P-55/I-8.17.5 |
| 27 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Type: 45 Watt LED or equivalent Ref: DELHI SCHEDULE OF RATES (E&M)-2025/P-51/I-8.13.11 |
| 28 | GST 18% |
| 29 | LWC 1% |
| 30 | Electrical Service connection charges from C.E.S.C Ltd/W.B.S.E.D.C. Ltd. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender