Tender For Supply & Installation Of Led Street Lights At Dharsa Seth Para, Khayer Aambagan, Dharsa Panchanantala, Dharsa Harisabhatala & Jagacha Under Ward No.47 Of Hmc.
Tender Value
11.74 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
17 days left
EMD
23482
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Howrah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply & Installation Of Led Street Lights At Dharsa Seth Para, Khayer Aambagan, Dharsa Panchanantala, Dharsa Harisabhatala & Jagacha Under Ward No.47 Of Hmc.
BOQ
| Sl. No. | Item Description |
| 1 | Erection of single steel Tubular pole of length as given below with /without sole plate & cap etc. in C.C. foundation (Proportion and dimension indicated below). having 600 x 600 x 150 mm. thick C.C. (4:2:1) base block below sole plate/pole with hard jhama metal incl. C.C (6:3:1) muffing 0.30 Mt.dia and 0.30 Mt above ground level incl.3mm thick neat cemented finished and G.I. earth bolt after making drilled holes etc.on pole & Carriage of pole upto 1.6 Km from store to work site incl. filling up the excavated earth pit with shifted soil and ramming properly. Pole upto 9 Mts. Size- 0.6 x 0.6 x 1.70 Mts. Ref: PWD/Elec.works/2017/P-H-1/I-1 |
| 2 | Distribution wiring for street light on pole for outdoor fluorescent / SV / MV light fitting with 2 x 1 / 1.40 PVC insulated and sheathed wire (single core) in 15 mm dia GI pipe (ISI-Medium) without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI pipe bracket of length 1.05 mts., on pole incl. S&F suitable MS flat clamps with bolts, nuts etc. as required and painting. Ref: PWD/Elec.works/2017/P-H-5/I-H(2) |
| 3 | Supplying & fixing GI waterproof type looping cable box size 200 x 150 x 100mm deep having 4mm thick comprising of one 250Volts 15 A Kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2 core 16 sqmm PVC/A cable and having lined with rubber gasketted CI top cover with brass machine screws etc. earthing terminal with lug,on steel tubular pole near base, incl. S & F 40 x 6 mm thick, MS clamps with bolts, nuts etc.incl.painting with anticorrosive paint. Ref: PWD/Elec.works/2017/P-H-5/I-H(5) |
| 4 | Painting of steel tubular pole of length and no.of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl.prepartion of surface by sand paper/emery paper,cleaning etc.for receiving fresh coat of paint upto 9 Mts. long pole:- 2 coats of Aluminium Paint over 1(one) coat of R.O.priming. Ref: PWD/Elec.works/2017/P-H-2/I-4 |
| 5 | Painting Block Letters or Digits within a circle/square as required, with \\"Black Japan\\" paint of approved make & brand, the size of letters and digits as given below: Size 50 mm and upto75 mm. Ref: PWD/Elec.works/2017/P-H-2/I-6(b) |
| 6 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (hot Dip) wire (4 Mts.long), 13 mm dia x 80 mm long GI bolts, double nuts,double washers incl. S&F 15 mm dia GI pipe protection (1 Mt.long)to be filled with bitumen partly under the ground level and partly above groung level driven to an average depth of 3.65 Mts.below the ground level. By ISI-Medium G.I Pipe. Ref: PWD Elec Works 2017 |
| 7 | Supply of Al.Conductor PVC insulated and sheathed unarmoured cable (1.1 KV grade, Gloster/Havells/Polycab). 4 Core x 10 mm.2. Ref: UDMA/Elec.-Mech.works/2018/P-13/I-3© |
| 8 | Supplying & Erection of 75 x 88 mm Porcelain Shackle insulator complete with 190 x 30 x 5 mm Galv.(Hot Dip) Strips with 15.88mm dia Galv. bolts, nuts, etc. for conductor upto 7/3.10 mm, 32 sqmm of AAC/equivalent size of ACSR. Ref: PWD/Elec.works/2017/P-H-3/I-D(1) |
| 9 | Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing & Drawing of unarmoured cable of suitable size (supply of cable is not included in the scope)on existing Galvanized stranded wire for centenary system with reel insulators and binding wires. Ref: UDMA/Elec.-Mech.works/2018/P-8/I-41&42 |
| 10 | Supplying of Swaged Steel Tubular pole(IS 2713,Pt. II 1980) for following designation and of following dimensions 4 SWG ;5.0 mtrs; 45 Kg Ref: UDMA/Elec.-Mech.works/2018/P-3/I-1(b) |
| 11 | Hoisting fixing and commissioning of luminaries including making necessary connection and earthing attachment: Ref: UDMA/Elec.-Mech.works/2018/P-35/I-7 |
| 12 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Type: 45 Watt LED or equivalent Ref: DELHI SCHEDULE OF RATES (E&M)-2025/P-51/I-8.13.11 |
| 13 | GST 18% |
| 14 | LWC 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender