Tender For special Repair To Vertical Shafts And Seepage In Mohan Enclave Under Ge (West) Delhi Cantt-10.
Tender Overview
Project Description
Tender for special Repair To Vertical Shafts And Seepage In Mohan Enclave Under Ge (West) Delhi Cantt-10.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Sep-2026 | date amdt | Date | 10-Oct-2026 |
| 2 | 14-Sep-2026 | date corrigendum | Date | 02-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : HQ CWE NO 2 DELHI CANTT-10 NAME OF WORK: SPL REPAIR TO VERTICAL SHAFTS AND SEEPAGE IN MOHAN ENCLAVE UNDER GE (WEST) DELHI CANTT-10. Contract No : CWE/WEST/TOKEN-29/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length including mild steel stack clamps (as per sample) fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls and including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc removal rubbish beyond MOD land complete all as specified and directed. Note:- Work will executed in shaft area up to eight storay scaffolding etc will arrange by contractor. |
| 3 | S&F 75mm bore PVC (SWR) pipes single socketed, in any length including mild steel stack clamps (as per sample) fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls and including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc removal rubbish beyond MOD land complete all as specified and directed. |
| 4 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 5 | S&F 110mm bore PVC (SWR) junction single, (Single T) with access door equal or unequal complete all as specified and directed. |
| 6 | S&F 110mm bore PVC (SWR) bends with rubber ring joints fixed to walls complete all as specified and directed. |
| 7 | S&F 110mm bore PVC (SWR) bends with access door with rubber ring joints fixed to walls complete all as specified and directed. |
| 8 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 9 | S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 10 | S&F 75mm bore PVC (SWR) bends with rubber ring joints fixed to walls complete all as specified and directed. |
| 11 | S&F in repairs 100mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 12 | Dismantling of floor size not exceeding 4.00 sqm for EWC water closet and removing out the cinder/concrete from sunken portion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditions, grinding any sharp edges etc all as specified and directed.(i) cleaning of RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(ii ) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal 107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika R Fab-I and top coat with Sika Top R Seal-107 @ 1.50 kg/sqm or equivalent of Fosroc or pidilite.(iii) M&L for protection plaster 15 mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika R plastocrete plus as specified. |
| 13 | (iv) M&L for providing 25 mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall.(v) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(vi) The area of Each WC portion is n exc 4.00 Sqm each.(vii) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note: The work will be executed by authorised manufacturers/applicater. |
| 14 | Dismantling of floor size not exceeding 4.00 sqm for EWC water closet and removing out the cinder/concrete from sunken portion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditions, grinding any sharp edges etc all as specified and directed.(i) cleaning of RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(ii ) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal 107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika R Fab-I and top coat with Sika Top R Seal-107 @ 1.50 kg/sqm or equivalent of Fosroc or pidilite.(iii) M&L for protection plaster 15 mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika R plastocrete plus as specified.(iv) M&L for providing 25 mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall. |
| 15 | (v) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(vi) The area of Each WC portion is n exc 4.00 Sqm each.(vii) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note: The work will be executed by authorised manufacturers/applicator. |
| 16 | M&L painting two coats of synthetic enamel paints over a coat of red oxide primer on new steel surfaces exc 10mm girth including preparation of surfaces complete all as specified and directed. |
| 17 | S&F in repairs 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and directed. |
| 18 | S&F in repairs 1.00 mm thick plain black mild steel sheeting in as in door shutter covering including, welding or soldered joint complete all as specified and directed. |
| 19 | M&L for 10mm thick rendering on concrete surface/brick surface in cement mortar (1:6) surface finished even and fair including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed, rubbish of the premises complete all as specified and directed. |
| 20 | Taking up or down 15 mm bore of galvanised iron steel tubing and connections complete all as specified and directed. |
| 21 | Taking up or down 20 mm bore of galvanised iron steel tubing and connections complete all as specified and directed. |
| 22 | S & F 32 mm dia medium grade galvanised steel tubes with all fittings and fixed or concealed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 23 | S&F in repair 20mm outer dia of CPVC pipe SDR11 & plain CPVC SDR 11 fittings in trenches, complete all as specified and directed. |
| 24 | S&F in repair 20mm outer dia of CPVC pipe SDR11 & plain CPVC SDR 11 fiittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 25 | S&F in repair 20mm CPVC brass elbow complete all as specified and directed . |
| 26 | S&F in repair 20mm CPVC Brass Tee complete all as specified and directed. |
| 27 | S&F PVC (SWR) floors trap with grating including jointing to waste pipe using solvent with dia of out let 75mm including floor around to required depth to facilitate dismantling old trap and making good complete all as specified and directed. |
| 28 | S&F in repairs brass face internal fittings for bib tap and pillar tap. |
| 29 | S&F in repairs 32mm dia waste fitting brass chromium plated for wash hand basin and Sink as per site requirement complete all as directed. |
| 30 | S&F in repairs 100 mm dia CP grating round with hole / without hole size as per site rquiremet complete all as specified and directed. |
| 31 | S&F in repairs 32mm dia and 750mm long PVC waste pipe for WHB and kitchen sink with union complete all as specified and directed. |
| 32 | S & F in repairs PVC valveless, syphonic action type flushing cistern 10 ltr capacity low level white or coloured with inlet, ball valve float and handle including brackets complete all as specified and directed. |
| 33 | M&L Non skid joint free colour Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM (1:6) complete all as spd and directed. |
| 34 | M&L for Glazed ceramic Coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile over 10mm thick backing coat in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 35 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed. |
| 36 | Cutting chases in Brick walls for concealed water tubing or concealed conduit wiring, etc. and making good,cutting exceeding 20cm girth complete all as specified and as directed. |
| 37 | M&L preparation of surfaces by complete removal of existing treatment & applying two coats of cement base paint on walls over a coat of primer all as specified & directed. |
| 38 | Taking down door/window/ventilator frames with shutters not exc 1.50 sqm each (without taking off shutters from frame) all as specified. |
| 39 | M&L for framed work as in door/vent/CB chowkats of angle or other section, frame work for chajja with gusset plates, cooler stand, rails, braces etc complete drilled for fixing of steel sheeting or other covering and including cutting brick work for hold fast confirming to Fe 410-W (Gde-E-250) quality 'A' including necessary welding and including dismantling wrought iron or mild steel work of any description not otherwise provided for concrete all as specified and directed. Note :- Work will executed up to 8 th storay and rate will quoted incl shifting of material by lift or pully as possible. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender