Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57199997

Tender For Repair/Maintenance Of Lt Panels, Apfc Panels And Connected Works At Itarana Military Station Under Ge Alwar

Issued by Statutory Bodies & Commissions/Committees · Alwar, Rajasthan
Tender Value
88000
Estimated cost
Bid Submission
16 Sep 2026
17 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Alwar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Lt Panels, Apfc Panels And Connected Works At Itarana Military Station Under Ge Alwar

BOQ

Name of Work:- REPAIR/MAINTENANCE OF LT PANELS, APFC PANELS AND CONNECTED WORKS AT ITARANA MILITARY STATION UNDER GE ALWAR
Sl. No. Item Description
1Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT underground electric cable with aluminium stranded conductor, 1100 Volt grade, 240 sqmm, 3½ core, laid in trenches/ducts, through pipes, under floors or roads/along poles etc complete all as specified including dismantling and taking out old unserviceable cable. Make: Havells/Grandlay/Polycab. Note: Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earthwork shall be measured and paid for separately.
2All as per Item No. 1 here-in-before but of cross-sectional area 185 sqmm, 3½ core.
3All as per Item No. 1 here-in-before but of cross-sectional area 120 sqmm, 3½ core.
4All as per Item No. 1 here-in-before but of cross-sectional area 95 sqmm, 3½ core.
5Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of poles/struts/stays, laying of cables, pipes etc and getting out in soft/loose soil complete all as specified.
6M&L for dry sand and punning for cushioning to underground cable all as directed. Note: For the purpose of payment, only punned thickness shall be measured.
7M&L for brickwork with fly ash bricks conforming to IS 13757:1993, old size bricks, laid dry and flat, abutted with each other with gap between adjacent bricks not exceeding 10 mm over underground cable for protection complete all as specified and directed.
8Returning, filling, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
9Removal of excavated soil/material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
10Boring of holes under road, pavement and hardstanding by trenchless technology using ultra-sonic technique and necessary machinery including HDPE pipe 80 mm dia suitable for 0.4 MPa working pressure complete all as specified.
11Taking down old unserviceable galvanized iron tubing, 40–80 mm bore, light grade, laid in trenches/under roads/drains or fixed on poles/walls complete all as specified.
12M&L for galvanized iron tubing, 50 mm bore, light grade, ISI marked, including all fittings and laid in trenches/under roads/drains or fixed to poles/walls with required size of flat iron 25 x 3 mm clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed. Make: Jindal/Prakash/Tata.
13All as per Item No. 12 here-in-before but of 80 mm bore.
14Repairs/replacement of PCC pole and S&F steel tubular swaged pole 9 metre long, Type 410 SP-31, including two coats of synthetic enamel paint in alternate black and yellow strips of 30 cm each up to 1.20 metre height from top of PCC coping/pedestal and two coats of aluminium paint over one coat of aluminium red oxide primer to remaining portion of pole and marking pole number, including dismantling and taking down old unserviceable prestressed concrete pole 9 metre long, all as specified and directed. Note: Excavation & earthwork, PCC in foundation and coping shall be measured and paid for separately.
15Demolition of cement concrete, unreinforced, of any description and in any position as in coping/pedestal of poles complete.
16M&L for PCC (1:4:8) Type D2 using 40 mm graded crushed stone aggregate as in foundation of stay assembly and poles and similar works complete all as specified. Note: Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
17M&L for PCC 1:3:6 Type C2 using 40 mm graded stone aggregate in mass concrete for pole complete all as specified and directed.
18M&L for PCC 1:2:4 Type B2 using 20 mm graded crushed stone aggregate in coping concrete for pole complete all as specified and directed.
19M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, cubicle type, size 1200 x 1000 x 500 mm, suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply, CPRI tested, dust and vermin proof, IP-65 degree of protection, fabricated from minimum 3.2 mm thick CRCA/MS sheet steel, powder coated externally over one coat of red oxide primer and internally with two coats of red oxide primer, double-sided opening type, complete with insulated aluminium busbar chamber, detachable bottom gland plate with suitable cable glands, internal wiring with IS-694 marked 1100 V grade PVC insulated solid copper conductor cables of suitable size but not less than 2.5 sq mm, instrument control fuses, RYB indication lamps, cable terminals, lugs, ferrules, labels and earthing terminals, including mounting 450 mm above ground level on 900 mm long 50 x 50 x 6 mm angle iron frame welded at four corners and embedded in PCC 1:2:4 using 20 mm graded aggregate up to 300 mm above ground level, complete all as specified and directed, comprising of the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 630 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 800 A complete with insulators – 04 Nos. OUTGOING: 3 pole adjustable thermal magnetic MCCB 400 A, 36 kA – 02 Nos.; provision for 01 No. additional MCCB; 4 pole adjustable thermal magnetic MCCB 200 A, 25 kA – 02 Nos.; 4 pole adjustable thermal magnetic MCCB 100 A, 25 kA – 02 Nos.
20M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, complete as per above item but with the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 400 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 600 A complete with insulators – 04 Nos. OUTGOING: 4 pole adjustable thermal magnetic MCCB 200 A, 36 kA – 01 No.; 4 pole adjustable thermal magnetic MCCB 160 A, 36 kA – 03 Nos.; 4 pole adjustable thermal magnetic MCCB 100 A, 25 kA – 01 No.
21M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, complete as per above item but with the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 315 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 400 A complete with insulators – 04 Nos. OUTGOING: 4 pole adjustable thermal magnetic MCCB 250 A, 25 kA – 02 Nos.; 4 pole adjustable thermal magnetic MCCB 160 A, 25 kA – 02 Nos.
22M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, complete as per above item but with the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 400 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 600 A complete with insulators – 04 Nos. OUTGOING: 4 pole adjustable thermal magnetic MCCB 250 A, 36 kA – 02 Nos.; 4 pole adjustable thermal magnetic MCCB 160 A, 25 kA – 01 No.; 4 pole adjustable thermal magnetic MCCB 100 A, 25 kA – 01 No.
23M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, complete as per above item but with the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 400 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 600 A complete with insulators – 04 Nos. OUTGOING: 4 pole adjustable thermal magnetic MCCB 200 A, 25 kA – 02 Nos.; 4 pole adjustable thermal magnetic MCCB 160 A, 25 kA – 03 Nos.
24M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, complete as per above item but with the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 400 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 600 A complete with insulators – 04 Nos. OUTGOING: 3 pole adjustable thermal magnetic MCCB 250 A, 36 kA – 02 Nos.; 3 pole adjustable thermal magnetic MCCB 200 A, 36 kA – 02 Nos.; 3 pole adjustable thermal magnetic MCCB 160 A, 25 kA – 02 Nos.; 3 pole adjustable thermal magnetic MCCB 100 A, 25 kA – 01 No.
25M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, complete as per above item but with the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 315 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 600 A complete with insulators – 04 Nos. OUTGOING: 4 pole adjustable thermal magnetic MCCB 200 A, 36 kA – 02 Nos.; 4 pole adjustable thermal magnetic MCCB 160 A, 25 kA – 02 Nos.; 4 pole adjustable thermal magnetic MCCB 125 A, 25 kA – 02 Nos.; 4 pole adjustable thermal magnetic MCCB 100 A, 25 kA – 01 No.; 4 pole adjustable thermal magnetic MCCB 63 A, 25 kA – 01 No.
26M&L for replacement of existing old unserviceable LT panel and supply, installation, testing and commissioning of factory-made, floor-mounted outdoor type LT feeder panel board, complete as per above item but with the following: INCOMING: 4 pole adjustable thermal magnetic MCCB 250 A, 36 kA – 01 No.; digital combined ammeter & voltmeter 10/0–400/500 A/V – 01 No.; aluminium busbar 600 A complete with insulators – 04 Nos. OUTGOING: 4 pole adjustable thermal magnetic MCCB 250 A, 25 kA – 01 No.; 4 pole adjustable thermal magnetic MCCB 100 A, 25 kA – 01 No.
27M&L for replacement of existing old unserviceable APFC panel and supply, installation, testing and commissioning of automatic intelligent APFC capacitor bank panel, LT, 3 phase, 440 V, 50 Hz AC, suitable for automatic step-wise power factor correction from 0.80 to 0.90 or better/near unity, floor mounted outdoor type, weather, dust and vermin proof, fabricated from minimum 16 SWG CRCA/MS sheet with 40 x 40 x 6 mm angle iron frame, factory made modular construction, duly powder coated light grey, front openable lockable shutter, natural air cooled, complete with cable entry and removable gland plate, suitable internal busbars, supports, wiring, terminals, lugs, ferrules, labels and earthing terminals, mounted on PCC 1:3:6 Type C-1 foundation 450 mm below and 300 mm above ground level around supporting legs, complete with capacitor discharge resistors, individual step protection, capacitor-duty contactors and suitable detuned reactor/harmonic protection provision as required by harmonic study, comprising:-(i) Incomer MCCB, 4 pole, 160 A, 36 kA, 440 V AC – 01 No.(ii) MCB, TP, 63 A, 'C' curve – 06 Nos.(iii) Capacitor-duty contactor, 3 pole, 25–63 A – 06 Nos.(iv) Self-healing cylindrical power capacitor, 25 KVAR, 440 V, 3 phase, 50 Hz – 02 Nos.(v) Self-healing cylindrical power capacitor, 20 KVAR, 440 V, 3 phase, 50 Hz – 01 No.(vi) Self-healing cylindrical power capacitor, 10 KVAR, 440 V, 3 phase, 50 Hz – 01 No.(vii) Self-healing cylindrical power capacitor, 5 KVAR, 440 V, 3 phase, 50 Hz – 02 Nos.(viii) Microprocessor-based APFC relay, 6/7 stage, with digital PF indication, CT sensing, programmable switching/reconnection delay and automatic step control – 01 No.
28M&L for replacement of existing old unserviceable APFC panel and supply, installation, testing and commissioning of automatic intelligent APFC capacitor bank panel, LT, 3 phase, 440 V, 50 Hz AC, suitable for automatic step-wise power factor correction from 0.80 to 0.90 or better/near unity, floor mounted outdoor type, weather, dust and vermin proof, fabricated from minimum 16 SWG CRCA/MS sheet with 40 x 40 x 6 mm angle iron frame, factory made modular construction, duly powder coated light grey, front openable lockable shutter, natural air cooled, complete with cable entry and removable gland plate, suitable internal busbars, supports, wiring, terminals, lugs, ferrules, labels and earthing terminals, mounted on PCC 1:3:6 Type C-1 foundation 450 mm below and 300 mm above ground level around supporting legs, complete with capacitor discharge resistors, individual step protection, capacitor-duty contactors and suitable detuned reactor/harmonic protection provision as required by harmonic study, comprising:-(i) Incomer MCCB, 4 pole, 200 A, 36 kA, 440 V AC – 01 No.(ii) MCB, TP, 63 A, 'C' curve – 07 Nos.(iii) Capacitor-duty contactor, 3 pole, 40–63 A – 07 Nos.(iv) Self-healing cylindrical power capacitor, 25 KVAR, 440 V, 3 phase, 50 Hz – 03 Nos.(v) Self-healing cylindrical power capacitor, 20 KVAR, 440 V, 3 phase, 50 Hz – 02 Nos.(vi) Self-healing cylindrical power capacitor, 10 KVAR, 440 V, 3 phase, 50 Hz – 01 No.(vii) Self-healing cylindrical power capacitor, 5 KVAR, 440 V, 3 phase, 50 Hz – 01 No.(viii) Microprocessor-based APFC relay, 7 stage, with digital PF indication, CT sensing, programmable switching/reconnection delay and automatic step control – 01 No.
29M&L for earthing to electrical equipment/panels including galvanized MS earth plate electrode 600 x 600 x 6 mm thick, buried vertically to required depth, surrounded by charcoal dust and salt, excavation and earthwork, GI MS strip 25 x 3 mm earth lead, GI pipe protection, clamps, bolts, nuts and washers, PCC chamber, MS funnel with wire mesh, GI watering pipe and RCC cover on CI frame, including dismantling and taking out old unserviceable earthing complete all as specified and directed.
30S&F in repairs decorative colour pole light of 3 metre length with GI PU painted pipe pole and polycarbonate/acrylic light material, suitable for Tiranga colour illumination in saffron, white and green sequence, complete with driver, base plate 300 mm dia x 12 mm thick with 260 mm dia PCB hole and 25 mm dia mounting arrangement, fixed on PCC foundation with foundation bolts complete all as specified and directed. Make: Halonix/Havells/Bajaj or equivalent as approved by GE.
31M&L in repair of broken coping/new/refixing of existing pole for PCC 1:2:4 Type B2 using 20 mm graded stone aggregate in coping concrete for pole complete all as specified and directed.
32Supply and laying in replacement XLPE insulated, armoured, heavy-duty electric cable with stranded aluminium conductor, 1100 V grade, laid in trenches, ducts, pipes, drawn across roads/paths/drains/along poles/walls/floors/equipment etc including jointing and testing complete all as specified, size 4 core 25 sqmm.
33All as per Item No. 32 here-in-before but of size 16 sqmm x 2 core.
34All as per Item No. 32 here-in-before but of size 16 sqmm x 4 core.
35S&F in repairs LED security light fitting, 90 W, 230 V AC, outdoor type, high-pressure die-cast aluminium housing, heat-resistant, complete with driver, lamp bracket, impact and corrosion-resistant construction, thermal management in multiple optics and IP-65/66 protection complete all as specified and directed. Make: Havells/HPL/Crompton/Shakti.
36All as per Item No. 35 here-in-before but of 100 W capacity.
37All as per Item No. 35 here-in-before but of 120 W capacity.
38S&F in repairs 2.5 sqmm PVC insulated and FRLS PVC round-sheathed twin-core flexible copper conductor industrial cable, 1100 V grade, conforming to IS 694, from security light feeder/junction box to security light fittings. Make: Havells/Finolex/Polycab.
39S&F in repairs 2.5 sqmm PVC insulated and sheathed twin-core aluminium conductor cable from security light feeder/junction box to security light fittings. Make: Havells/Finolex/Polycab.
40Supply and fixing for pole-mounted junction box made out of one-piece moulded SMC, IP-65 protection, having 100 A aluminium busbars, 3 phase and neutral, with 1 No SPN 6 A MCB for street light, cable entry from bottom, maintenance-free, size 300 x 200 x 100 mm, fixed on pole with MS flat 25 x 3 mm clamps including nuts and bolts, front openable complete all as specified and directed. Make: Sintex/Universal/Siemens/ABB. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57199997
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 88000
LAST DATE 16-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Lt Panels, Apfc Panels And Connected Works At Itarana Military Station Under Ge Alwar
Basic Detail
Tender No 8566/E8
Bidding Type Tender
Location
City Alwar
State Rajasthan
Key Dates
Publish Date 25 Aug 2026
Submission Date 16 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value 88000
Tender Fee 500
EMD 88000
Exemption Available
Document List
36a0c4ff-c868-4cf0-8468-802aaab64532.html
BOQ_881151.xls
Tender8566.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

36a0c4ff-c868-4cf0-8468-802aaab64532.html

xls

BOQ_881151.xls

pdf

Tender8566.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders