Tender For Certain Repair/Maint Of Lt Panels, Feeder Pillar Boxes, Lt Switch Gears, Valve Pit Chambers, Joints, Filtration Plant Ug Pipe Lines, Centrifugal Pump Sets Etc And Other Allied Works At Af Stn Faridabad Under Aor Of Ge (Af) Faridabad
Tender Overview
Project Description
Tender for Certain Repair/Maint Of Lt Panels, Feeder Pillar Boxes, Lt Switch Gears, Valve Pit Chambers, Joints, Filtration Plant Ug Pipe Lines, Centrifugal Pump Sets Etc And Other Allied Works At Af Stn Faridabad Under Aor Of Ge (Af) Faridabad
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed. |
| 2 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed. |
| 3 | Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 4 | Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 6 | Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 185 Sqmm 3.5 core complete all as specified and directed. |
| 7 | All as per item No 06 above but Size 95 sqmm 3.5 core. |
| 8 | All as per item No 06 above but Size 70 sqmm 3.5 core. |
| 9 | All as per item No 06 above but Size 50 sqmm 3.5 core. |
| 10 | All as per item No 06 above but Size 35 sqmm 3.5 core. |
| 11 | All as per item No 06 above but Size 16 sqmm 4 core. |
| 12 | All as per item No 06 above but Size 10 sqmm 4 core. |
| 13 | Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine with HDPE Pipe, PN 10,100 mm dia complete all as specified and directed. |
| 14 | Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches duly painted with two coat of black metallic paint after a primer coat of red oxide complete all as specified and directed. |
| 15 | All as per item No14 above but 50 mm dia |
| 16 | All as per item No 14 above but 40 mm dia. |
| 17 | M&L for cable end termination kit out door, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16sqmm 4 core core with working voltage 1100 volts incl necessary excavation returning filling & removal complete all as specified and directed. |
| 18 | All as per item No 17 above but Size 25-35 sqmm 4 core. |
| 19 | All as per item No 17 above but Size 50-95 sqmm 3.5 core. |
| 20 | All as per item No 17 above but Size 120 - 185 qmm 3.5 core. |
| 21 | M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16 Sqmm 4 core with working voltage 1100 volts complete all as specified and directed. |
| 22 | All as per item No 21 above but Size 25-35 sqmm 4 core. |
| 23 | All as per item No 21 above but Size 50-95 sqmm 3.5 core. |
| 24 | All as per item No 21 above but Size 120 - 185 qmm 3.5 core. |
| 25 | S&F in repairs MCCB 4 pole 415 volts fixed type 400 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 26 | S&F in repairs MCCB 4 pole 415 volts fixed type 315 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 27 | S&F in repairs MCCB 4 pole 415 volts fixed type 250 Amps with braking capacity 25KA after taking out old U/S one complete all as specified and directed. |
| 28 | S&F MCCB 4 pole 415 volts in repairs,fixed type 200 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed. |
| 29 | S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 30 | S&F in repairs MCCB 3 pole 415 volts fixed type 125 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 31 | S&F MCCB 3 pole 415 volts in repairs,fixed type 63 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed. |
| 32 | S&F in repair sheet metal enclosures DB Double door Verticle distribution type, 08 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed. Note : - MCCB shall be measured and paid separately |
| 33 | Supply & fixing in replacement of MCB SP 6 t0 32 amps 230 Volt complete all as specified and directed. |
| 34 | S&F in repairs Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed. |
| 35 | S&F in repairs Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and directed. |
| 36 | S&F MNX 18, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed. |
| 37 | S&F MNX 95, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed. |
| 38 | S&F MNX 70, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed. |
| 39 | S&F MN contactor 18 Amps in existing model and make including after taking out old unserviceable one, complete all as specified and directed. |
| 40 | M & L for servicing of volatge stabilizer auto servo controlled on balanced type 3 ph naturally cooled of capacity 100 to 160 KVA of make : Volina, by disconnecting the LT cables and draining out oil complete and taking out the core and checking the continuity and insulation values of all three phases, reinsulating if required and inspecting and replacing the PCB and servicing of breaker, removing and cleaning the sludge from the tank, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric strength of oil not below 60 KV at 2.5 mm gap including testing of volatge stabilizer by reconnecting the disconnected cables and calibrating complete all as specified and direcrted. Note:The rate shall also deemed to be included the rate for Technician, Electrician,and labours. |
| 41 | M&L for Spring loaded finger of servo stablizer capacity complete all as specified and directed. |
| 42 | M&L for Microproccessor Based eletronic control board capacity complete all as specified and directed. |
| 43 | M & L for repairing , servicing and replacement of LT panels unsv part including complete accesories such as partialy open door , door breakers , Unsv Al bus bar , unsv locking arrangement, repairing of LT Panel legs, welding work , neceassry PCC work , Excavtaion , removal , retruning filling including disconnection and reconnection of cables , of any size any capacity complete all as specified and directed. |
| 44 | Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, for repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice, complete all as specified and directed. Note :- Old U/S items will be provided against respective items separately. |
| 45 | Removing all connections from LT panel having feeders above 04 Nos upto 08 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice,complete all as specified and directed. Note :- Old U/S items will be provided against respective items separately. |
| 46 | M&L for Painting of any size , any make LT panel after removing old dust partical,oily porytion by rubbing with sand paper with spary pump, and writing /digital printing ., Capacity Descripton, date of installation,etc complete all as specified and directed. |
| 47 | M & L for Scraping of old paint from two pole/ four pole structure without removing accessories and preparation of surfaces for repainting. Repainting the poles with one coat of alternative green and white strips of 30 cm each upto 1.5 mtr height using synthetic enamell paint . Marking the pole No with black enamell paint. Repainting the remaining Iron parts i.e. cross arms, supporting angles, XPM jali, clamps, GI bkt etc and steel pole above 1.5 mtr height by applying one coat of alumn paint or PCC pole with snowcem of approved color complete all as specified and directed. |
| 48 | Supply and fix in replacement Earth Leakage Relays , Instant trip , adjustable senstivity upto 60mA , 1 module , monitor earth leakge current and the output of the realay operates if the leakge current rises above a selected level ,including providing thimble for out going cables, wires etc and taking out unserviceable relay of any deccription / type etc complete from LT Panel / MCCB DB/ MCB TPN DB etc complete all as specified and directed. (Selec 800S) |
| 49 | Supply and fixing as in repair / replacement motarised changeover switches of 315 A , 4P (Four Pole) , 415 V, surfce mounted type with side handle operation including bridging bars & external handle with swtich is in ON position, OFF position and other DG/Sources ON position (three position ) complete including electrically connection and taking out unserviceable changeover swtich of existing make complete all as specified and directed. |
| 50 | Supply and fixing as in repair / replacement of UNSV Aluminum thimbles of size 10sqmm to 70sqmm as per site requirements, complete all as specified and directed. |
| 51 | Supply and fixing as in repair / replacement of UNSV Aluminium thimbles of size 95Sqmm to 185sqmm as per site requirements, complete all as specified and directed. |
| 52 | M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15 cm size complete all as specified and directed. |
| 53 | Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed. |
| 54 | Supply , installation, commissioning and testing as in replacement of old unsv LT panel any size including taking out old unsv panel of AC, 3 phase,415 volts,50 Hz,out door type control panel factory made approx size 1200x1200x450mm free standing ,dust proof, vermin and water proof tecno modular fully bolted with concealed hinges for all doors & PU foam gasket at doors, fabricated out of 3.15 mm thick CRCA sheet inclduing aluminium bus bar 630 Amps with front & backside door and locking arrangement, degree of protection-54. The metal will be treated in ten tank process . After thorough treatment , the panel will be epoxy powder coated, painted with standard and including volt meter, amp meter, indicator lamps, selector switches Fully compartmentalized designed. Inspection at factory premises. IP-54 certificate of CPRI also required complete complete all as specified and directed. INCOMING : (i) MCCB 400 Amp, 36 KA, 4 pole 415 volts.1 No OUTGOING : (i) MCCB 250 Amp, 36 KA, 4 pole 415 volts - 01 No (ii) MCCB 160 Amp, 36 KA, 4 pole 415 volts - 03 Nos(iii) MCCB 100 Amp, 36 KA, 4 pole 415 volts - 02 Nos(iv) Indicator set RYB-01 set of 03 Pcs only(v) Multifunction digital panel meter suitable to display amps, volts frequency etc-01 No including Cts of appropriate ratio.(vi) MCB, SP 10 Amp 03 Nos (for metering equipment).(vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.Note : (i) MCCBs shall have adjustable thermal magnetic release setting(ii) Drawing for panel shall be got approved from Garrison Engineer before dispatch.(iii) Panel shall be CPRI approved certified. |
| 55 | Supply , installation, commissioning and testing as in replacement of old unsv LT panel any size including taking out old unsv panel of AC, 3 phase,415 volts,50 Hz,out door type control panel factory made 1200x1050x400mm free standing ,dust proof, vermin and water proof tecno modular fully bolted with concealed hinges for all doors & PU foam gasket at doors, fabricated out of 3.15 mm thick CRCA sheet inclduing aluminium bus bar 480 Amps with front & backside door and locking arrangement, degree of protection-54. The metal will be treated in ten tank process . After thorough treatment , the panel will be epoxy powder coated, painted with standard and including volt meter, amp meter, indicator lamps, selector switches Fully compartmentalized designed. Inspection at factory premises. IP-54 certificate of CPRI also required complete all as specified and directed. INCOMING : (i) MCCB 315 Amp, 36 KA, 4 pole 415 volts.1 No OUTGOING : (i) MCCB 125 Amp, 36 KA, 4 pole 415 volts - 03 Nos (ii) MCCB 160 Amps,36 KA, 4 pole 415 volts - 02 Nos.(iii) MCCB 100 Amps,36 KA, 4 pole 415 volts - 02 Nos.(iv) MCCB 63 Amps,36 KA, 4 pole 415 volts - 02 Nos.(v) DG Changeover Arrangement: One number 315A, 4 Pole Motorised Changeover Switch (AMF compatible) / Electrically Interlocked MCCBs with mechanical and electrical interlocking between mains and DG incomers, complete with control wiring, indicating lamps, selector switches and auxiliary contacts.(vi) Indicator set RYB-01 set of 03 Pcs only(vii) Multifunction digital panel meter suitable to display amps, volts frequency etc-01 No including CTs of appropriate ratio.(viii) MCB, SP 10 Amp 03 Nos (for metering equipment).(ix) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed. Note : (i) MCCBs shall have adjustable thermal magnetic release setting(ii) Drawing for panel shall be got approved from Garrison Engineer before dispatch.(iii) Panel shall be CPRI approved certified. |
| 56 | M&L for Dehydration including filteration and cleaning of transformer oil by centifugal dehydration machine till to achieve Di-electric strength 50 KV at 2.5 mm gap testing of sample before and after dehydration and filteration complete all as specified and directed. Note:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the deptt. Test report to be submitted after completion of job. |
| 57 | Supply & Filling /pouring of transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and directed. Note:- Dielectric strength test shall be carried out at site before poring/ filling in transformers in the presence of Engr-in-Charge on the site. |
| 58 | M & L for earthing with steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed. |
| 59 | M&L for Design ,development ,supply commisiong and testing burnished metallic brown 99.99% pure copper material specially develpoed for earthing purpose T point terminal exothermic/ nut bolt/ breezing . ground tubular effective chemical earthing (CPRI tested for 25KA current capacity for LT line ) highly anticorrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mm 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long with alosing base plate of 80 mm secondary conductor to install with suitable connecting terminal cofirming of IS 3043 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resisitivity anticorrosive ,hygroscope medium around the earth system for improving the efficiency of current dissipation with cystalline conductive mixture CCM 25 kg per bag sufficient quantities required at site complete RCC earthing pit cover M&L complete bfc compound specified and as per ic 62561 acceptance chemical test Leaching, sulphur determination, corrosion, resistivity along with CPRI and chemical compound test report complete all as specified and directed. Note :-1. Excavation / drilling hole in hard rock is included in the rate quoted incld. T&P2. Min. resistance for earthing pit shall be less than 1 ohm.3. Drilling or earth work shall be included in the overall cost quoted by the contractor. |
| 60 | Supply and fix copper strip 20mm x 3.15 mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips complete all as specified and directed. |
| 61 | Supply and fix aluminium strip 25 mm x 4 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed. |
| 62 | Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long all as specified and directed. |
| 63 | S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed. |
| 64 | M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and directed. |
| 65 | M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed. |
| 66 | Attending Complaints by deploying sufficient labour for rectification of leakage of UG water pipe lines of size 50 mm bore of any description such as CI/DI/GI pipe line at any location including necessary excavation in any type of soil (approx 2 meter length,width 1.5 meter ,depth 1.5 meter) dewatering complete by using pump set as per site requirement, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material etc complete all as specified and directed. |
| 67 | All as per item No 66 above but of size 40 mm dia pipe line |
| 68 | All as per item No 66 above but of size 15/20/25 mm dia pipe line |
| 69 | Taking up or downs CI/DI pipes of size 80mm/100mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 70 | Supply laying and testing of Ductile Iron pipes in replacement of unserviceable DI pipe of 80 mm bore with spigot and socket ends centrifugal cast, class K-7 as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches including taking down complete all as specified and directed. |
| 71 | Supply laying and testing of CI pipes in replacement of unserviceable CI pipe of 80 mm bore with spigot and socket ends centrifugal cast, class K-7 as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches including taking down complete all as specified and directed. |
| 72 | Supply laying and testing of Ductile Iron pipes in replacement of unserviceable DI pipe of 100 mm bore with spigot and socket ends centrifugal cast, class K-7 as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches including taking down complete all as specified and directed. |
| 73 | M&L for replacement old valve chambers CI covers, Angular iron frames, CI cover suitable for following size etc complete all as specified and directed. |
| 74 | All as per item No 73 above 1350 mm x 1000 mm x 1200 mm internal dimension |
| 75 | All as per item No 73 above 900 mm x 900 mm x 1000 mm internal dimension |
| 76 | All as per item No 73 above 900 x 600 x 1000 mm internal dimension |
| 77 | Costruction of valve chamber in PCC 1:5:8 masonry built in CM(1:4) with MS covers 3 mm thick and locking arrangement including excavaton and earth works PCC (1;4;8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15 mm thick with Cm 1:4 painting with one coat of bituminous black paint on all steel surface for the following sizes chambers complete all as specified and directed:- |
| 78 | All as per item No 77 above 1350 mm x 1000 mm x 1200 mm internal dimension |
| 79 | All as per item No 77 above 900 mm x 900 mm x 1000 mm internal dimension |
| 80 | All as per item No 77 above 900 x 600 x 1000 mm internal dimension |
| 81 | Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall mounted, dust and vermin proof (IP 65 ingress protection) main LT Panel(In door type) suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of 50 KA for 1 sec , fabricated from 2 mm thick CRCA sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement mounted on angle iron frame made out of 50x50x6 mm frame with 6 nos legs not less than 45 cm fixed with nuts bolts of suitable size, including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. LT Panel shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position. Suitable arrangement shall be made for termination of multiple incoming cables. All kA values indicated shall be Ics breaking capacity. General Arangement drawings shall be got approved by GE before fabrication. Pre - dispatch inspection of panel shall be carried out by Rep. of accepting officer within overall cost quoted.INCOMER : (i) MCCB 315 Amp, 35 KA, 4 pole 415 volts.1 Nos (incoming), (II) Digital Volt Meter (0-500V) =01 No.,(iii) Digital Amps Mtr (0-200)=01 No.with suitable CT rating(iv) Selector Switches-02 Nos (3 phase volt meter,3 phase Ammeter), (v) Lamp LED,220 Volt, - 03 Nos OUTGOING : (i) MCCB 160 Amp, 25 KA, 4 pole 415 volts - 03 Nos(i) MCCB 125 Amp, 16 KA, 4 pole 415 volts - 02 Nos(i) MCCB 100 Amp, 16 KA, 4 pole 415 volts - 02 No.Note : MCCBs shall have adjustable thermal setting |
| 82 | M&L in replacement of fix butterfly valve (ISI marked) confirming to IS 13095 of size 100 mm complete all as specified and directed. |
| 83 | M&L in replacement of reflux valve with by pass arrengement of size 100mm dia complete all as specified and directed. |
| 84 | M&L in replacement of butterfly valve (ISI marked) confirming to IS 13095 of size 63 mm complete all as specified and directed. |
| 85 | M&L in replacement of fix Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixedmof size 25mm dia complete all s specified and directed. |
| 86 | Supply, laying & jointing of following CPVC pipes as per IS:15778 Standard Dimensional ratios SDR 11 Pressure bearing capacity of SDR 11pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² and SDR 13.5 @23°C is 22.5kg/cm² & at @82°C 5.60 kg/cm². CPVC fittings up to 50 mm are all SDR 11( including fittings as Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, Unions, Ball valves, Flange and tank adaptor ) as under complete all s specified and directed: |
| 87 | All as per item No 86 above for Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceilling or lying floors. |
| 88 | All as per item No 86 above for Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceilling or lying floors. |
| 89 | Supplying and laying & jointing of 50 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches (including excavation, removal and returning filling of any type of soil/road/wall of size 300 mm Depth, 250 mm wide) complete all s specified and directed |
| 90 | S & F in repair Male Brass Threaded Adaptor size 50 mm (MTA/ MBTA) complete all s specified and directed |
| 91 | S & F in repair Male Brass Threaded Adaptor size 25 mm (MTA/ MBTA) complete all s specified and directed |
| 92 | S & F in repair Female Brass Threaded Adaptor size 50 mm (FTA/ FBTA) complete all s specified and directed |
| 93 | S & F in repair Female Brass Threaded Adaptor size 25 mm (FTA/ FBTA) complete all s specified and directed |
| 94 | S & F in repair Brass Elbow size 50 mm complete all s specified and directed |
| 95 | S & F in repair Brass Elbow size 25 mm complete all s specified and directed |
| 96 | Dewatering the existing U/G sump of 40000 GLNS capacity and cleaning the internal surface of sump for removing scales, funges, mud and other foreign material ,scrubbing with water using wire brush and watering the surfaces with mixture of bleaching powder and water ,finally washing with fresh water and treating with one coat of lime wash to internal wall and bottom surfaces etc complete for one time,writing in enamel paint note in in block capital letter as cleaned on (date) and due date etc,height not less than 5 cm complete all s specified and directed |
| 97 | All as per item No 96 above but OHT cap reservoir of capacity 50000 Ltrs. |
| 98 | Dewatering the existing U/G sump of 100000 Ltrs capacity and cleaning the internal surface of sump for removing scales, funges, mud and other foreign material ,scrubbing with water using wire brush and watering the surfaces with mixture of bleaching powder and water ,finally washing with fresh water and treating with one coat of lime wash to internal wall and bottom surfaces etc complete for one time,writing in enamel paint note in in block capital letter as cleaned on (date) and due date etc,height not less than 5 cm complete all as specified and directed. |
| 99 | Dewatering the existing RO water tank 25000 Ltrs capacity and cleaning the internal surface of tank for removing scales, funges, mud and other foreign material ,scrubbing with water and watering the surfaces with mixture of bleaching powder and water ,finally washing with fresh water complete all as specified and directed. |
| 100 | S&F of Pen type TDS meter complete all as specified and directed. |
| 101 | Supply & installation and testing of Water Level Sensor for overhead tank /UG sump with 5 Stage % Digital displays of level of water and features of Buzzer alarm sounds on Low & High Levels. To differentiate the sound is intermittent on full level & continuous in case of low level. Option to mute the buzzing sound by pressing the ACK (Acknowledge)Push Button. Inclusive of Corrosion free Magnetic 5Nos. Sensors. complete all as specified and directed. |
| 102 | Supply and fixing Sensing 3 Core tinned Copper Cable multi strand for connection from sensor upto the indicator complete all as specified and directed. |
| 103 | Supply of STD Cartridge filter 2.5\\" dia x 20\\" long, 5 Micron complete all as specified and directed. |
| 104 | Supply of Jumbo Cartridge filter 4.5\\" dia x 20\\" long, 5 Micron complete all as specified and directed. |
| 105 | Supply of Indion antiscalant 8111 dosage @ 5 ppm complete all as specified and directed. |
| 106 | Supply of pH booster 2825 dosage @ 3 ppm or as per site condition complete all as specified and directed. |
| 107 | M&L Indion RO membrane alkaline cleaner 2814 dosage @ 2 Kg once in a month complete all as specified and directed. |
| 108 | M&L Indion RO membrane Acidic cleaner 2811 dosage @ 2 Kg once in a month complete all as specified and directed. |
| 109 | M&L filtering sand media includes pebbles, gravels, course silex, fine silex etc as required complete all as specified and directed. |
| 110 | M&L activated carbon media as required complete all as specified and directed. |
| 111 | M&L 2.5\\" F/M SS pressure gauge, range (0-7 kg/cm2) complete all as specified and directed. |
| 112 | M&L 2.5\\" F/M SS pressure gauge, range (0-21 kg/cm2) complete all as specified and directed. |
| 113 | M&L 2.5\\" P/M SS pressure gauge, range (0-7 kg/cm2) complete all as specified and directed. |
| 114 | M&L 2.5\\" P/M SS pressure gauge, range (0-21 kg/cm2) complete all as specified and directed. |
| 115 | M&L low pressure switch range (0-7 kg/cm2) complete all as specified and directed. |
| 116 | M&L high pressure switch range (0-21 kg/cm2) complete all as specified and directed. |
| 117 | M&L Chemichal dosing pump (0-6 LPH) complete all as specified and directed. |
| 118 | M&L RO membrane HM 8040-BWE-400 complete all as specified and directed. |
| 119 | M&L RO membrane HM 4040-BWE-400 complete all as specified and directed. |
| 120 | M&L 8\\" end cap assy end port with L key clamp, 300 PSI complete all as specified and directed. |
| 121 | M&L 4\\" end cap assy endport with key clamp, 300 PSI complete all as specified and directed. |
| 122 | S&F of strainer assy 4\\" extra long as required complete all as specified and directed. |
| 123 | Supply, installation, testing and commissioning in repair of Single Phase Preventer (SPP-2) suitable for 415 Volts ±10%, 3 Phase, 50 Hz AC supply for protection of three-phase induction motors against single phasing, phase failure, phase reversal, phase unbalance, under/over voltage and dry run (where applicable), complete with all necessary accessories including wiring, terminals, glands, lugs, fixing hardware, interconnections, testing and commissioning, complete all as specified and directed. |
| 124 | Supply, installation, testing and commissioning in repair of paddle type water flow switch suitable for chilled water/hot water/HVAC piping, complete with SPDT micro-switch, adjustable flow setting, IP65 weatherproof enclosure, stainless steel paddle, brass/bronze body, suitable for pipe sizes 25 mm to 150 mm (1” to 6”), operating pressure up to 10 bar, fluid temperature up to 100°C, electrical rating 24–250 V AC, complete with all mounting accessories, wiring connections, testing and commissioning, complete all as specified and directed. |
| 125 | Supply, installation, testing and commissioning in repair of electronic Water Sensor Switch/Water Leakage Detection Sensor with controller, suitable for detection of water leakage in AHU rooms, pump rooms, plant rooms, under raised floors and other critical areas, complete with sensor probe, controller module, relay output (NO/NC), LED status indication, audible alarm, operating voltage 230V AC/24V DC, IP65 enclosure, interconnecting cable, mounting accessories, all wiring, testing and commissioning, complete in complete all as specified and directed. |
| 126 | Dismantling the components of Reverse Osmosis plant (5000 Ltrs per hour capacity 03 Nos) and checking the serviceability of plant including rubber bushes,fittings,low pressure /high pressure motor pumps and re fixing the same after necessary repairs and replacement of unserviceable parts complete all as specified and directed. |
| 127 | Dismantling the components of Reverse Osmosis plant(1000 ltr per hour/250 ltr per hour) and checking the serviceability of plant including rubber bushes,fittings,low pressure /high pressure motor pumps and re fixing the same after necessary repairs and replacement of unserviceable parts complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender