Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57199931

Tender For Repairs /Maint/Replcement To Reinforced Cement Concrete Chajja, Parapets, Window, Railing, Plinth, Rwp Alongwith Drain And Cleaning Of Pvc Tanks With Other Connected Works At 24 Ed Af Stn

Issued by Statutory Bodies & Commissions/Committees · Prayagraj, Uttar Pradesh
Tender Value
13.88 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
18 days left
EMD
28000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs /Maint/Replcement To Reinforced Cement Concrete Chajja, Parapets, Window, Railing, Plinth, Rwp Alongwith Drain And Cleaning Of Pvc Tanks With Other Connected Works At 24 Ed Af Stn

BOQ

Name of Work:- Repairs /Maint/Replcement to RCC Chajja, Parapets, Window, Railing, Plinth, RWP alongwith drain and cleaning of PVC Tanks with Other connected works at 24 ED AF Stn
Sl. No. Item Description
1Dismantling of Brick tiles or terracing tiles, single layer on roofs bedded in cement mortar & disposal of retrieved materials upto a distance n. exc 100 mtr and deposited where directed complete all as specified
2Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) & disposal of retrieved materials upto a distance n. exc 100 mtr and deposited where directed complete all as specified
3Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and as directred by Engr-in-Charge
4Demolistion of brick work built in cement mortor
5Taking down cement plaster on brick/concrete surace of wall/ceiling etc
6Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
7Taking down existing roof treatment and cleaning roof surface by brushing washing rubbing etc,
8Taking down steel tubing & connection incl cleaning for refixing or removal to store for 15mm dia complete all as specified and directed
9Taking down steel tubing& connection incl cleaning for refixing or removal to store for 20mm d ia complete all as specified and directed
10Demolition of re-inforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
11Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified
12M&L for PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in roof padding/curving sides of parapet wall complete all as sspecified and directed.
13M&L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface mixed with WPC @ 200ml per bag of cement or as per manufacturere instruction and as directed by engr-in-charge. NOTE:- WPC will be measured and paid seperately.
14Supply and applying high build elastomeric water proofing coating based on pure hydrophobic, cold applied spray/brush applied , amart care PU magnum membranne with and elongation of 450% and tensile strength of 2.5 N/Sqmm as per ASTM D 2370. crack bridging ability of 3mm as per ASTM 1305, no leakage upto 7 bars of water pressure as per DIN 1048 shore a hardness of min 45 as per ASTM D 2240. The system includes final base preparation , Epoxy Primer application and applying smart care PU magnum or approved equivalant in two coats with a consumption of 1.5 Kg/Sqm on a primed surface with smart care primer and a 40GSM geo textile cloth sand wiched in between etc. Complete all as per manufacturer instruction/ specification.
15Supply only Water proffing liquid compound (ISI Marked) complete all as per specified and directed
16M&L brushing neat cement slurry with 3 Kg of cement /Sqm complete all as specified and directed.
17M&L for 15mm thick rendering in CM (1:3) on edge of RCC chajja or corners of columns where steel reinforcement coming out after fixing 15mm size wire netting of mild steel wire 1.60mm dia fixed with tinned tacks of wire staples including taking down plaster complete all as specified and directed.
18M&L for brick work with sub class 'B' brick straight or curved onplan exc 6 m mean radius built in CM 1:6
19M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 m mean radius in half brick thick wall built in CM 1:4
20M&L 15mm thick in cement plaster 1:4 with WPC @ 3% by weight of cement by weight of cement on fair faces of brick/concrete surface finishing the surface even and smooth without using extra cement complete all as specified and directed.
21M&L for Rendering 10mm thick in cement mortar (1:6) on brick/concrete surface of wall on fair faces of brick work or concrete surfaces finished even and smooth without using exra cement
22M&L for Rendering 5mm thick in cement mortar (1:3) on brick/concrete surface of ceiling l on fair faces , finished even and smooth without using exra cement
23M&L for preparation of new plaster surface of wall including cornice and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
24M&L for preparation of roof treatmment of APP polymeric water proofing membrane all as given below:-(a) Taking down existing water proofing treatment and cleaning roof by brushing and rubbing etc and removing retrieved material to a distance n .exc 500 mtr where directed.(b) M&L for plastering 10mm thick in CM 1:3 using 100% coarse asand on roof suface including waater proffing compound as per manufacturer instruction and as directed by Engr-in-Charge.(c ) Applying a coat of bitumenous primer confirming to IS-3384-1986 @ 0.40 Ltr/Sqm and allow to dry.(d) Applying and laying 3mm thick APP membrane having weight 3.2 to 3.50 Kg on prepared susrface as per manufacturer instruction and over laps 10cm and 15cm longitudinal and traverse direection respectively and sealed by flame , sealing all overlaps complete including treatment at all junction and corner. The membrane shall be torched into grooves on vertical plane and groove sealed with cement mortar 1:3(e ) Screed bed 15mm thick in CM 1:4 as in bedding layer using 100% coarse sand.(f) M&L for 20-25mm thick roof tiles set and jointed in neat cement slurry as in tarrace over screed bed complete all as specified and directed by Engr-In-Charge
25M&L for preparation of roof treatmment of APP polymeric water proofing membrane all as given below:-(a) Taking down existing water proofing treatment and cleaning roof by brushing and rubbing etc and removing retrieved material to a distance n .exc 500 mtr where directed.(b) M&L for plastering 10mm thick in CM 1:3 using 100% coarse asand on roof suface including waater proffing compound as per manufacturer instruction and as directed by Engr-in-Charge.(c ) Applying a coat of bitumenous primer confirming to IS-3384-1986 @ 0.40 Ltr/Sqm and allow to dry.(d) Applying and laying 3mm thick APP membrane having weight 3.2 to 3.50 Kg on prepared susrface as per manufacturer instruction and over laps 10cm and 15cm longitudinal and traverse direection respectively and sealed by flame , sealing all overlaps complete including treatment at all junction and corner. The membrane shall be torched into grooves on vertical plane and groove sealed with cement mortar 1:3(e ) Applying two coats of aluminium paint over membrane @ 0.20 Kg/Sqm and all as per specifiecation and as directed by Engr-in-Charge
26S&F in repair PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as directed by Engr-In-Charge
27S&F in repair PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as directed by Engr-In-Charge
28S&F in repair PVC (SWR) bends 110 mm dia any radius fixed in poaition complete
29S&F in repair PVC (SWR) bends 75 mm dia any radius fixed in poaition complete
30S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 110mm dia complete all as specifiwed and directed by Engr-In-Charge
31S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 75mm dia complete all as specifiwed and directed by Engr-In-Charge
32S&F 15mm GI tubing medium grade for flush pipes fixed dto wall, floor, trenches or ceiling 15mm dia complete all as specified and directed by Engr-In-Charge.
33S&F 20mm GI tubing medium grade for flush pipes fixed dto wall, floor, trenches or ceiling 15mm dia complete all as specified and directed by Engr-In-Charge.
34Disconnecting of existing tanks of 500 Ltr to 1000 Ltr capacity setting aside ( or lowering if required) for repairs, cleaning etc, and hoisting if required reconnecting and re-fixing in position ( including cleaning, marking date of cleaning etc Complete all as specified. Please Enable Macros to View BoQ information
35Disconnecting of existing tanks of 500 Ltr to 1000 Ltr capacity setting aside ( or lowering if required) for repairs, cleaning etc, and hoisting if required reconnecting and re-fixing in position ( including cleaning, marking date of cleaning etc Complete all as specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57199931
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13.88 Lakhs
LAST DATE 16-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs /Maint/Replcement To Reinforced Cement Concrete Chajja, Parapets, Window, Railing, Plinth, Rwp Alongwith Drain And Cleaning Of Pvc Tanks With Other Connected Works At 24 Ed Af Stn
Basic Detail
Tender No CANO. CWE(AF)CHK/MNR/T-10 OF 2026-27 82489/E8/E8
Bidding Type Tender
Location
City Prayagraj
State Uttar Pradesh
Key Dates
Publish Date 25 Aug 2026
Submission Date 16 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 13.88 Lakhs
Tender Fee 500
EMD 28000
Exemption Available
Document List
a862bdd9-5b11-440b-9d4c-805dbc34a2b2.html
BOQ_881171.xls
Tendernotice_1.pdf
TenderT10.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

a862bdd9-5b11-440b-9d4c-805dbc34a2b2.html

xls

BOQ_881171.xls

pdf

Tendernotice_1.pdf

pdf

TenderT10.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders