Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57199928

Tender For Work Services Required For Installation Of Sdr & Conversion Of Oh Line To Ug Lt Line At Afs Suryalanka

Issued by Statutory Bodies & Commissions/Committees · Guntur, Andhra Pradesh
Tender Value
7.68 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
13 days left
EMD
15360
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Guntur → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Work Services Required For Installation Of Sdr & Conversion Of Oh Line To Ug Lt Line At Afs Suryalanka

BOQ

Name of Work:- WORK SERVICES REQUIRED FOR INSTALLATION OF SDR & CONVERSION OF OH LINE TO UG LT LINE AT AFS SURYALANKA
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: AGE (I) Suryalanka Name of Work: WORK SERVICES REQUIRED FOR INSTALLATION OF SDR & CONVERSION OF OH LINE TO UG LT LINE AT AFS SURYALANKA Contract No: AGE (I) / SL / OF 2026 - 27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Works Item Code / Make Approximate No. of Units Required UNIT Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Taking down chowkats or frames (without taking off shutters from frame ) not exceeding 1.5 sqm each all as specified and directed.
3M&L for Brickwork with sub-class `B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 all as specified and directed.
4M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:6 finishing fair and evev smooth including preparation of surfaces complete all as specified and as directed
5M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:6 finishing even and smooth with out using extra cement all as specified and directed.
6M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer all as specified and directed.
7M&L preparing new surfaces of walls plastered or uplastered and applying two coats of Exterior emulsion paint over a coat of primer to match existing surfaces complete all as spd and as directed.
8S&F Of Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasketetc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
9M&L for 12 mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations fixed to aluminum doors / partitions all as specified and directed.
10Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 3.5 core 35 Sqmm
11Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cable n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil complete all as specified and as directed.
12Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
13Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
14Supply and laying of 63mm size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing in the trench, complete as required.
15Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 4 core 16 Sqmm
16S&F in replacement submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 6 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitalbe size ISI marked Medium grade, fixed on/through wall, ceiling including 6 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed.
17Supply, installation, commissioning and testing of LT panel outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting frame made out of angle iron 45 x 45 x 6 mm and four numbers of 200 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following:Incoming:-(a) 100 Amp 36kA 4 Pole MCCB -01 Nos(b) Intelligent panelmeter with indication lamps-01Out going:-MCCB 63 Amp 4 pole 25kA -01 NosMCCB 40 Amp 4 pole 25kA-01 Nos
18Supply and fixing 100Amps 4 pole MCCB extendable rotary handle mounting on the existing LT Panel incl necessary mounting arrangements all as directed by engr-in-charge
19Supply and fixing MCB DB TPN 4 Way horizontal double door 415V AC 50Hz for MCB FP as incommer and TP/DP/SP MCBs as outgoing with tinned copper bus bar, neutral link earth link complete all specified and as directed.
20Supply and fixing MCB TPN 40Amp 415V 16kA 'C' Curve miniature circuit breaker in the DB complete with connection testing and commissioning complete all as specified and directed
21Supply and fixing MCB SPN 6-32Amp 415V 10kA 'C' Curve miniature circuit breaker in the DB complete with connection testing and commissioning complete all as specified and directed
22Supply and fixing MCB 6-32Amp 415V 10kA 'C' Curve miniature circuit breaker in the DB complete with connection testing and commissioning complete all as specified and directed
23Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
24Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected sing galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
25Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 70 Sqmm 3.5 Core
26(b) 50 Sqmm 3.5 Core
27Supply and laying of 100mm size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing in the trench, complete as required.
28Supply, installation, commissioning and testing of LT panel (CPRI approved) outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting frame made out of angle iron 40 x 40 x 6 mm and four numbers of 200 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following:Incoming:-(a) 200 Amp 36kA 4 Pole MCCB -01 Nos(b) Intelligent panelmeter with indication lamps-01Out going:-MCCB 100 Amp 4 pole 36kA -02 NosMCB SPN 40 Amp 25kA-02 Nos
29Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected sing galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57199928
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7.68 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Work Services Required For Installation Of Sdr & Conversion Of Oh Line To Ug Lt Line At Afs Suryalanka
Basic Detail
Tender No AGE(I)/8764
Bidding Type Tender
Location
City Guntur
State Andhra Pradesh
Key Dates
Publish Date 25 Aug 2026
Submission Date 09 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 7.68 Lakhs
Tender Fee 500
EMD 15360
Exemption Not Available
Document List
8764PS.pdf
8764Tenderdoc.pdf
8b6a5e2b-d214-4be8-b9d4-6358851a5034.html
BOQ_881221.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

8764PS.pdf

pdf

8764Tenderdoc.pdf

html

8b6a5e2b-d214-4be8-b9d4-6358851a5034.html

xls

BOQ_881221.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders