| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: REPAIR/MAINT OF FANS, GEYSERS, COOLING APPLIANCES ,WINDOW/SPLIT TYPE AC, REFRIGERATOR , AIR BLOWER, DEEP FREEZER, INTERNAL WIRING AND SUBMERSIBLE PUMPS, CHLORINE DOSING PLANTS AND CI/DI WATER PIPELINES IN GRD KUNRAGHAT, NCC, GYANGHAR MIL STN UNDER GE(AF) GORAKHPUR. Contract No.: GE(AF)/GKP/E-31 OF 2026-27 File No. 9470/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of item Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 3 | M&L for One Light/fan point controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with sunmica/Bakelite sheet 3mm thick and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed for following :- |
| 4 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on same board…...ditto as above…. |
| 5 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on independent board.…...ditto as above…. |
| 6 | Ditto as above but for One bell point controlled by one 5 Amps bell push.…...ditto as above…. |
| 7 | Ditto as above but for One light point controlled by two 5 Amps two way switch.…...ditto as above…. |
| 8 | M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with sunmica/Bakelite sheet 3mm thick including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 2 to 5 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 9 | M&L for point wiring One Light/fan point controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including PVC casing caping all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes with sunmica/Bakelite sheet 3mm thick and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. |
| 10 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on same board.…...ditto as above…. |
| 11 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on independent board....ditto as above…. |
| 12 | Ditto as above but for One bell point controlled by one 5 Amps bell push.…...ditto as above…. |
| 13 | Ditto as above but for One light point controlled by two 5 Amps two way switch.…...ditto as above…. |
| 14 | M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including PVC casing caping with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with sunmica/Bakelite sheet 3mm thick including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 15 | S&F in replacement switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed. |
| 16 | S&F in replacement socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed. |
| 17 | S&F in replacement socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 18 | S&F in replacement switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed. |
| 19 | S&F in replacement bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed. |
| 20 | S&F in replacement ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed. |
| 21 | S&F in replacement fan regulator electronic step up type, 80/100W SP 230 volt complete all as specified and as directed. |
| 22 | S&F in replacement lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed. |
| 23 | S&F in replacement Call bell ding dong, AC single pole 240 volts complete all as specified and directed. |
| 24 | Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed. |
| 25 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 26 | S&F in replacement 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. LHEBAEP71W1W036 or equivalent in Bajaj / CG. |
| 27 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 28 | Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffusersoft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copperconductor cable of suitable size complete |
| 29 | S&F in replacement, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED Street light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Philips or equivalent in Havells, Crompton |
| 30 | S&F in replacement, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED flood light fitting with high power LED as light source complete fixed on wall using nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-PhilipsBVP120LED35CWFG or equivalent in Havells, Crompton |
| 31 | Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed. |
| 32 | M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5 sqmm conductor cable, 1 No 1.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length) |
| 33 | M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length). Make : Havells, KEI, Grandlay |
| 34 | M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 Sqmm conductor cable, 1 No. 4.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length) Make : Havells, KEI, Grandlay |
| 35 | Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 36 | S&F in replacement factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed. |
| 37 | S&F in replacement factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 38 | S&F in replacement factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 39 | S&F in replacement MCCB, 4 pole, 63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 40 | S&F in replacement MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 41 | S&F in replacement MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed. |
| 42 | S&F in replacement MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 43 | S&F in replacement MCB, SPN, 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 44 | S&F in replacement MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 45 | S&F in replacement MCB, TP, 25 to 63 Amps, 'C' curve, 10 KA breaking capacity, 415 volts complete all as specified and directed. |
| 46 | S&F in replacement MCB, TPN, 40 to 100 Amps, 'C' curve, 10 KA breaking capacity, 415 volts complete all as specified and directed. |
| 47 | S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified. |
| 48 | S&F in replacement in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 250mm sweep with louvers, plastic body, with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed.Make: Havells/Bajaj/CG. |
| 49 | S&F in replacement in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 300mm sweep with louvers, plastic body with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed.Make: Havells/Bajaj/CG. |
| 50 | S&F in replacement in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 300mm sweep with louvers, steel body with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed.Make: Havells/Bajaj/CG. |
| 51 | S&F in replacement in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 450mm sweep with louvers, steel body with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed.Make: Havells/Bajaj/CG. |
| 52 | S&F in replacement in replacement unsv wall mounted fan single phase 230/240 volt AC 400mm sweep, with regulator, oscillation type complete fixed properly on wall and connecting /testing as directed. Note Old unsv fan will be deposited to E/M store yardMake: Havells/Bajaj/CG. |
| 53 | Repairing of light point (normal/ flameproof), fan point, socket point 5A/15A, switches sockets, fan regulator, light fixtures any type, lamp any type, MCB DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected minor accessories by providing sufficient and skilled manpower. Work shall also include to check & removal of current leakages in Bldgs and any urgent nature of work as and when directed. The scope also include cutting of existing Bakelite sheet to accommodate new elect fittings/fixtures like switches, sockets, fan regulators etc. Note :- (a) The rate quoted by the contractor for Each Job is deemed to be included consisting of minimum 03 complaints. (b) The contractor or his representative will take complaint from MES complaint Register through MES job card. (c) The contractor will made separate items register with location and signature of user. (d) The contractor will maintain complete details of Job cards (Working/Off working hours) and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor. (f) Risk factor & security pass will be the contractor's end. (g) If the complain will not attend within 24 hours a penalty of Rs. 500/- for per complain will be imposed on Contractor.(h) All supply material shall be deposited by contractor in MES store yard and issued in every Job Card as per requirement. (j) The tradesmen should be available at MES area complaint cell (In MES Complex), after completing their daily Job Cards as well as during off working hours / Night / Sunday / Holiday. |
| 54 | Supply and fixing in replacement switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed. |
| 55 | Supply and fixing in replacement switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed. |
| 56 | Supply and fixing in replacement switch socket combination multipurpose 5 pin 5 Amps |
| 57 | Supply and fixing in replacement switch socket combination multipurpose 5 pin 5/15 Amps |
| 58 | Supply and fixing in replacement socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed. |
| 59 | Supply and fixing in replacement socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 60 | Supply and fixing in replacement bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed. |
| 61 | Supply and fixing in replacement modular bell push pole 1 way, 1 module, 6 Amp complete all as specified and directed. |
| 62 | Supply and fixing in replacement ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed. |
| 63 | Supply and fixing in replacement Call bell ding dong, AC single pole 240 volts complete all as specified and directed. |
| 64 | Supply and fixing in replacement lamp LED 10 watt, 240 volts complete all as specified and directed. |
| 65 | S&F in replacement Modular switch 1 way 10A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 66 | S&F in replacement Modular switch 1 way 20A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 67 | S&F in replacement modular socket, 6A - 2/3 pin combined 2module complete all as specified and directed by Engineer in charge. |
| 68 | S&F in replacement modular socket outlet 2 in 1, 6 pins 6A and 16A, combined module, complete all as specified and directed by Engineer in charge. |
| 69 | S&F in replacement modular fan regulator complete all as specified and directed by Engr-in-charge |
| 70 | S&F in replacement modular white cover plate with frame, 12 module, complete all as specified and directed by Engineer in charge. |
| 71 | S&F in replacement modular white cover plate with frame, 8 module, complete all as specified and directed by Engineer in charge. |
| 72 | S&F in replacement modular white cover plate with frame, 6 module, complete all as specified and directed by Engineer in charge. |
| 73 | S&F in replacement modular white cover plate with frame, 3 module, complete all as specified and directed by Engineer in charge. |
| 74 | S&F in replacement modular white cover plate with frame, 2 module, complete all as specified and directed by Engineer in charge. |
| 75 | S&F in replacement modular white cover plate with frame, 1 module, complete all as specified and directed by Engineer in charge. |
| 76 | Supply and fixing in replacement tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed. |
| 77 | S&F in replacement in replacement ball bearing No. 6200 to 6203 complete all as specified and directed.Make:-SKF/NRB/NBC/TATA |
| 78 | S&F in replacement in replacement gun metal bush of any description and size to suit existing motor shaft complete all as specified and directed. |
| 79 | S&F in replacement in replacement capacitor of capacity 2.5 mfd PVC body complete all as specified and directed. Make:- EPCOS/JYOTI/ USHA |
| 80 | S&F in replacement in replacement capacitor of capacity 3.15 mfd PVC body complete all as specified and directed. Make:- EPCOS/ JYOTI/ USHA |
| 81 | Supply and fixing in replacement wire flexible 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed. |
| 82 | S&F in replacement in replacment old and UNSV ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and as directed.Note : UNSV fans will be deposited to MES Store by Contractor. |
| 83 | Disconnecting, taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans and pedestal fans etc. of any description, any sweep and from any position/locations for repairs/servicing/numbering, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The replacement of defective/ nonfunctional parts shall be measured & paid separately as “Supply and fixing in replacement” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item here-in-after. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa. |
| 84 | Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mm sweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department for the following Fans:- Make of winding wire: Atlas/Finolex/ Devi Dayal |
| 85 | All as per item No. 83 above but rewinding of motor of exhaust fans of 225/250 mm sweep with 170 gram winding wire. |
| 86 | All as per item No. 83 above but rewinding of motor of exhaust fans of 300/400 mm sweep with 200 gram winding wire. |
| 87 | S&F in replacement PVC Casing caping of size 25mmx16mm complete all as specified and directed |
| 88 | S&F in replacement modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20/25 Amps capacity complete all as specified and directed. |
| 89 | S&F in replacement SS Screws of dia 6mm with long plug shaft for fixing of casing caping complete all as specified and directed |
| 90 | S&F in replacement fastener bolts for fixing of geysers complete all as specified and directed |
| 91 | S&F in replacement in replacement 3 core PVC insulated and FR PVC Round Sheathed, Copper Conductor 2.50sqmm each core, 1100 volts grade complete all as specified and directed. |
| 92 | S&F in replacement in replacment motor, single phase for 200/250mm Exhaust fan as per sample complete all as specified and directed. |
| 93 | S&F in replacement in replacement Switch Socket combination unit with box having 20A Switch, 6A/16A Socket, 240 volts complete all as specified and directed. |
| 94 | Taking down geysers carefully of any type and make of capacity 25 ltrs after disconnecting water supply and electrical connection, opening of geysers for inspection of unserviceable parts followed by servicing overhauling after replacement of unserviceable component with cleaning of heating element and inner tank by de-scaling including assembling fixing in position, making all electrical & water supply connection, making functional and testing complete all specified and directed.Note:- Components/spare part required for replacement shall be paid for separately under respective item here in after as Supply and fixing in replacement/issue only on demand. |
| 95 | All as per item No above but of capacity 50 ltrs. |
| 96 | Supply and fixing in replacement heating element ISI marked 1.5 KW suitable for geyser of 25 litres, horizontal or vertical type of any make complete all as specified and directed. |
| 97 | Supply and fixing in replacement heating element ISI marked 2.0 KW suitable for geyser of 25 litres, horizontal or vertical type of any make complete all as specified and directed. |
| 98 | Supply and fixing in replacement heating element pin type (Triangular) 1.5 KW rating capacity 230 V, ISI marked complete all as specified and directed. |
| 99 | Supply and fixing in replacement heating element pin type 2.0 KW rating capacity 230 V, ISI marked complete all as specified and directed. |
| 100 | Supply and fixing in replacement thermostat minimum 300mm long ISI marked suitable for geyser of 25/50 litres, horizontal or vertical type of any make complete all as specified and directed. |
| 101 | Supply and fixing in replacement power indicating lamp circular/rectangle type suitable for 25/50 ltrs capacity geyser complete all as specified and directed. |
| 102 | Supply and filling up glass wool suitable for geyser of 25/50 litres, horizontal or vertical type of any make complete all as specified and directed. |
| 103 | M&L for repairing leakage of inner copper tank of geyser (any make) 25/50 litres capacity by brazing including all necessary denting etc complete all as specified and directed. |
| 104 | Supply and fixing in replacement of inner copper cell geyser (any make) 25 litres capacity and making connections by brazing including all necessary accessories complete all as specified and directed. |
| 105 | Supply and fixing in replacement of inner copper cell geyser (any make) 50 litres capacity and making connections by brazing including all necessary accessories complete all as specified and directed. |
| 106 | Renewal of base assembly complete suitable for geyser (any make) 25 litres capacity and making connections by brazing including all necessary accessories complete all as specified and directed. |
| 107 | Renewal of base assembly complete suitable for geyser (any make) 50 litres capacity and making connections by brazing including all necessary accessories complete all as specified and directed. |
| 108 | Supply and fixing in replacement top or bottom cover for any make of geyser of 25 Ltrs capacity complete all as specified and directed. |
| 109 | Supply and fixing in replacement top or bottom cover for any make of geyser of 50 Ltrs capacity complete all as specified and directed. |
| 110 | S&F in replacement in replacement hot water supply CP/PVC connection pipe of size 450mm long heavy duty with check nut for 15 mm dia pipe ISI marked complete all as specified and directed. |
| 111 | S&F in replacement in replacement plug top of polycarbonate 3 pin, 15/16 Amp, 230 V complete all as specified and directed. |
| 112 | S&F in replacement in replacement plug top metallic 3 pin, 20 Amp, 230 V complete all as specified and directed. |
| 113 | S&F in replacement in replacement gun metal non return valve heavy duty 15mm dia complete all as specified and directed. |
| 114 | S&F in replacement in replacement of fusible plug chromium plated brass (ISI marked) suitable for any type of geyser complete all as specified and directed. |
| 115 | Supply and fixing in replacement gasket with stud for aperture assembly of any type geyser complete all as specified and directed. |
| 116 | Supply and fixing in replacement safety pressure/air lock valve suitable for geyser 25/50 Ltrs capacity complete all as specified and directed. |
| 117 | Checking of leakage in refrigerant system of water cooler of 150 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas R. 22 in required quantity all as directed by Engineer-in-Charge. |
| 118 | S & F (in repairs) gas filter, flare type ¾\\" x ½\\" flare all as directed by Engineer-in-Charge |
| 119 | S & F(in repairs) copper capliery for water cooler of any size, as directed by Engineer-in-Charge |
| 120 | Dismantling of existing repairable water cooler of any make and capacity from its position including disconnecting of electric connections, transporting from site to contractor's workshop including loading/unloading for repairs and replacement of defective body and spares reassembling and transporting back to site including ,installation of water cooler on existing foundation and making electric & water supply connection etc (notes:- Replacement of defective item shall be measured & paid for separately). |
| 121 | M&L replacement of pipe connector for water cooler including flange, screw, nozzle of nipple female nozzle and extention all chromium plated. |
| 122 | Supply & fixing (in repairs) push cock chromium plated (inner or outer threaded) of 15 mm bore size complete as in water cooler, ,complete all as spcified and directed.by the Engineer-in-Charge |
| 123 | Taking out of unservicable compressors of Water Cooler 40 Ltrs including desconnecting suction / discharge copper tubing and replacing by new compressor of model CR-22 with nuts, bolts rubber grommet and washer, connecting copper tubing by welding, flare nuts etc complete all as specified and directed by EIC. |
| 124 | Servicing of Split /Window type AC of Capacity 1.5 ton any make/ model incl removing the AC and cleaning ,Oiling, servicing and checking for proper functioning and re-fixing at site comp all as directed Note:- Spare parts will be measured and paid separetly |
| 125 | Checking of unserviceable Window/split AC/Water Cooler/Desert Cooler U/S parts likewise relay,compressor,blade,motor, gas leakage,condensor coil,capacitor,Thermostate,Filter,PCB,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs (b) The contractor or his representative will take complaint from MES complaint Register through MES job card (c)The contractor will made seprate items register with location and signature of user (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature (e) The ladder and T&P as required will be provided by the contractor (f) Risk Factor will be the contractor 's end |
| 126 | Replacement of condensing coil for 40/80 Ltr. Capacity water cooler of any make , complete all as specified and diected . |
| 127 | S&F in replacement float valve 15mm dia suitable for water cooler. |
| 128 | S&F in replacement relay for compressor for water cooler |
| 129 | S&F in replacement starting capacitor ,50Mfd |
| 130 | S&F in replacement running capacitor, 36mfd. |
| 131 | S&F in replacement in replacement starting relay for 1.5 TR / 2 TR compressor all as specified and directed by EIC. |
| 132 | S&F in replacement in replacement of overload protector for 1.5 TR / 2 TR compressor ,complete all as spcified and directed by EIC. |
| 133 | S&F in replacement in replacement Thermostate switch for 1.5 TR / 2 TR AC compressor all as specified and directed (Make:- Carrier / Voltas / LG) |
| 134 | S&F in replacement in replacement swing motor for 1.5 TR split AC ,complete all as spcified and directed by EIC (Make:- LG / Carrier /Blue Star/ Voltas) |
| 135 | S&F in replacement in replacement reverse cycle solenoid valve in split type AC 1.5 TR / 2 TR capacity with necessary extension to suction / discharge copper tubing & toggle switch complete all as specified and directed by EIC. |
| 136 | S&F in replacement in replacement suction copper pipe line heavy duty 1/2\\" dia with foam insulation and flair nuts from indoor to outdoor unit of split AC 1.5 TR / 2 TR capacity ,complete all as spcified and directed. |
| 137 | All as per item bove but discharge copper pipe, heavy duty 1/4\\" dia. |
| 138 | S&F in replacement PVC insulated three core stranded copper cable of size 3 core 6 sqmm ,complete all as spcified and directed. (Make:- Paragon / Havells / Seicko /Finolex) |
| 139 | S&F in replacement copper gas filter for AC 1.5 TR / 2 TR capacity ,complete all as spcified and directed. |
| 140 | S&F in replacement PVC pipe nylon imbraded 15 mm dia for condensed water drain fitted with clamps / concealed in wall ,complete all as spcified and directed. |
| 141 | Taking out of unservicable compressors of 1.5 TR capacity including disconnecting suction / discharge copper tubing and replacing by new compressor of model CR-22 with nuts, bolts rubber grommet and washer, connecting copper tubing by welding, flare nuts etc, complete all as specified and directed by EIC. |
| 142 | M & L for rewinding of blower motor for 1.5 ton AC with superior quality of super enameled copper conductor of appropriate sizes in existing weight and gauge incl replacement of Bush/Bearing, commissioning and testing complete all as specified and directed. |
| 143 | M & L for gas charging in Split type A/C unit 1.5/2 ton capacity using refrigerant as per standard practice after flushing, vacuuming incl detecting leakage, rectification of leakage, commissioning and testing complete all as specified and directed |
| 144 | Supply and fixing in replacement of new auto swing motor for window/split type AC 1.5 TON/2 TON all as spcified. |
| 145 | Supply and fixing Fan Blower set for 1.5 Ton Split type AC (as per sample) complete all as spcified and directed |
| 146 | S & Fin replacement of new vertical water lifting pump, single phase, 1/7 HP or any HP suitable for desert coolers complete in all respect. (Make : summerking/Summer cool /MEI/Crompton |
| 147 | S & F in replacement of fan motor 1/7 HP or any HP 230V, 50 Hz cycles A/C supply complete in all respects complete all as specified and directed. (Make : summerking/Summer cool /MEI/Cromptonsummerking) |
| 148 | Supply and fixing wood wool pad for deser cooler of suitable size with connected acces. (one set of 3nos) |
| 149 | Installation /Re-installation only split tye Air conditioning electrically driven ,230/250V ,AC 50 Hz capacity 1.5/2.0 Ton with high wall mounted type fan coil unit (FCU) to be fitted in wall with rowl plugs including making holes for inlet /outlet in the wall and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer all as spcified |
| 150 | M & L for rewinding of 5 KVA main transformer of voltage stablizer using superior quality of super enameled copper of core matching size complete with varnising dying and re-fitment in stablizer complete all as specified and directed |
| 151 | M & L for rewinding of 4 KVA main transformer of voltage stablizer using superior quality of super enameled copper of core matching size complete with varnising dying and re-fitment in stablizer complete all as specified and directed |
| 152 | S & F in replacement of new PCB matching size of voltage stablizer 5/4KVA of single phase operation in AC supply complete all as specified and directed |
| 153 | S & F in replacement of battery TDR for voltage stablizer 4/5 KVA complete all as specified and directed. |
| 154 | S & F in replacement of voltmeter 0-300 volt for voltage stablizer 4/5 KVA complete all as specified and directed. |
| 155 | Carrying out pressure leak test of split Acs 1.5/2.0 TR by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out T&P required at site all as specified and directed. |
| 156 | Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR /2TR 3 TR including unserviceable corded electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit /match the existing system all as specified and directed by EIC. |
| 157 | Compressor rotary suitable for reversible cycle split type AC 1.5 TR (Original sealed unit is to supply ) of Make Blue Star, Videocon, Samsung, or its equivalent of other specified make as approved. |
| 158 | S&F in replacement cooling coil of 165 litres capacity refrigerator after disconnecting the cooling coil from refrigerator, N2 pressure testing and flushing out the system and charging of R-12 gas as per required quantity and testing complete all as directred by Engineer-in-Charge. |
| 159 | Supply and fixing condensing coil for 165 litres capacity refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of R-12 gas as per required quantity and testing complete all as directed. |
| 160 | Checking of leakage in refrigerant system of water cooler of 150 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas R. 22 in required quantity all as directed by Engineer-in-Charge. |
| 161 | S&F in replacement starting relay, open type for refrigerator of capacity 165 litres all as directed by Engineer-in-Charge (Make : Ranutrol/ Sriram/ Whirlpool) |
| 162 | S&F in replacement over load protector for 1/6 HP refrigerator of capacity 165/300 litres all as directed by Engineer-in-Charge. |
| 163 | S&F in replacement thermostat defrost type for refrigerator all as directed by Engineer-in-Charge. (Make - Ranutrol/ Indfoss) |
| 164 | S&F in replacement door gasket for 165 litres capacity refrigerator, any make all as directed by Engineer-in-Charge. |
| 165 | S&F in replacement butter shutter for any make refrigerator of 165 litres capacity. |
| 166 | S&F in replacement Defrost tray (Plastic) as per sample for 165 litres capacity refrigerator. |
| 167 | S & F in replacement Printed Circuit board (PCB) of ceiling fan 1200/1400mm sweep of any Make complete all as specified and direcetd by Engr-in-Charge. |
| 168 | Disconnecting & taking out to Submersible Pump/Motor of various Capacities and lifting from bore hole of Pump Houses and Transporting to nearest Workshop for repairing including returning back after repairing and Re-instaltion & lowering in Original Position and Re-connection in water supply installation and Testing complete all as specified and as directed by Engineer-in-charge.Note : Cost of repairs will be measured & paid separetely under respective item, here-in-after. |
| 169 | Dismantling to submersible Pump 15/ 25HP for repair & replace-ment of unserviceable spare-parts including necessary cutting, grinding, drilling, machine work for fixing of spares and re-assembling the Same and Tested in work shop, complete all as specified and as directed by Engineer-in-charge. Note:- (i) Defective spare parts (except bronze bushes) shall be measured & paid seprately under respective item of this shedule as supply only. But Fixing charges (Labour element ) shall be deemed to be included in the unit rate of this item without any extra cost. |
| 170 | Cutting & removing burn out motor winding of submersible pump set of capacity 15/25 HP pump set and cleaning complete & rewinding with superior quality of PVC insulated copper wire of same size & same gauge, weight and reassembling & testing complete as directed by Eng-in- Charge |
| 171 | Supply only thrust bearing/thrust plate suitable for submersible pump of 15/ 25HP capacity |
| 172 | Supply only motor housing bush (GM) suitable for submersible pump of 15/ 25HP capacity |
| 173 | Supply only Impeller bronze suitable for submersible pump of 15/ 25HP capacity |
| 174 | M&L Chlorine Testing Kit by Orthotolidine method with all accessories (colour matching PPM tubes, water testing tubes, Orthotolidine solution and wooden Box) complete all as specified and directed. |
| 175 | supply only Sand Guard and water seal. |
| 176 | supply only Bowl packing |
| 177 | supply only Impeller shaft sleeves suitable for submersible pump of 15/ 25HP capacity |
| 178 | supply only Impeller shaft (SS) suitable for submersible pump of 15/ 25HP capacity |
| 179 | supply only Bowl bush (GM) suitable for submersible pump of 15/ 25HP capacity |
| 180 | supply only Neckring (GM) suitable for submersible pump of 15/ 25HP capacity |
| 181 | supply only SS Coupling suitable for submersible pump of 15/ 25HP capacity |
| 182 | supply only Stud suitable for submersible pump of 15/ 25HP capacity |
| 183 | supply only Single phase preventer MAKE: Minilec/L&T |
| 184 | S&F in replacement 16Sqmm 3 Core submersible cable flat copper conductor all as specified and directed. |
| 185 | S&F in replacement star delta starter 3 phase 440V 28-42 amp rating fully automatic with enclosures. Model No CS96008 (MUG 30) of L&T or equivlent of specified make in PS. |
| 186 | S&F in replacement star delta starter 3 phase 440V 13-21 amp rating fullyautomatic with enclosures. Model No CS96008 (MUG 30) of L&T or equivlent of specified make in PS. equivlent of specified make in PS. |
| 187 | M&L for black column pipe heavy duty ISI marked 100 mm bore, wall thickness 5.4 mm 3 mtr length both end flanged with heavy duty pre drilled 8 holes welded inside and outside the flange and making smooth surface including of 04 strips 5.0 mm thick , 25 mm wide and 50 mm long covering pipe at flanged end on outside and duly painted with two coats of synthetic enamel paint over a coat of red oxide including dismanting of old pipe all as spcified and directed |
| 188 | Disconnecting electric connections and taking out submersible pump set of any capacity with column pipe of any length including cable for carring out development of bore well of any size and any length and lowering the same and connecting the electric cable after devolopment complete including testing for getting satisfactory discharge complete all as directed. |
| 189 | M&L cleaning of RCC overhead reservoir of capacity 100000 gallons through Mechanical tank cleaning process by involving the following six(6) stages of cleaning process and as directed by Engr-in-charge:- Location - NCC, GRD, APSa) De-watering by high pressure submersible pump all completeb) Total removal of sludges by suction pumps all complete.c) Cleaning of walls,ceiling and floor by high pressure jet of 80-180 bar pressure all completed) Removal of addl. sludge by industrial vacuum pump all complete.e) Antibacterial treatment of inside of tank to make it complete bacteria free and all complete.f) Treated with ultra violet radiatior to make it complete bacteria free all complete.Note:-(1) The entire work should be carried out by 6-Stage tank cleaning process by any franchises or M/S TANK CLEANING(Pvt) Ltd or any other MES approved firm having equivalent technology.(2) Entire T&P should be arranged by the contractor at their own.Only electric power & water shall be supplied by MES at stipulated rate.(3) (a) Date of cleaning ,(b) Capacity of tank should be written over the outer surface of tank by synthetic enamel paint with lettering not less than 100 mm height.Cost of the same is deemed inclusive in the quoted unit rate of cleaning of tank. |
| 190 | M&L chemical and bactirilogical testing of water and submission of report all as specified and directed . Particular of test to be carried out (a) PH(b) odour© Taste (d) TDS (e) turbidity (f) total Hardness (g) sulphate (h) chloride (j) Resdiual free chlorine (k) M P N coliform bacteria (Note : Testing shall be got by Govt agency) |
| 191 | S&F (in replacement) Water pressure Gauge 0-150 LBS/10.6 Kg complete icluding oil with brass stop cock all as specified and directedand taking out old one |
| 192 | Supply and fixing of 150 mm bore Non return ( Reflux) valve with GM working parts IS-5312 incl material & labour for jointing with rubber gasket , bolts, nuts , washer etc complete all as specified and directed by Engr-in-charge for following size incl taking down old valve. Make- Kirloskar, Leader,Ramco, Upadhaya & IVC. |
| 193 | Supply and fixing of 100 mm bore Non return ( Reflux) valve with GM working parts IS-5312 incl material & labour for jointing with rubber gasket , bolts, nuts , washer etc complete all as specified and directed by Engr-in-charge for following size incl taking down old valve. Make- Kirloskar, Leader,Ramco, Upadhaya & IVC. |
| 194 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep in Soft/loose, complete all as specified & directed. |
| 195 | Returning filling in incl, spreading leveling watering and well ramming in layer not exceeding 25 Cm think, complete all as specified & directed. |
| 196 | Removal of surplus soil not exceeding 50 Mtr and depositing where directed as level not exceeding 1.5 Mtr above the starting point, complete all as specified & directed. |
| 197 | M & L for Ductile iron fitting (any type & any radius/angle) such as bend tee connecting pieces. Double branch (cross collar cap and any type of end reducer Y -janction etc complete for pipe upto 150 mm dia normal complete as specified and directed. |
| 198 | Opening of leakage joints in 150 mm bore CI pipe line and taking out lead joints by burning /melting incl supplying and refilling the lead points caulking incl excavation & earth work, complete all as specified and directed. (Note: old lead shall be reused again) |
| 199 | All as per item No above but 100 mm bore, complete all as specified and directed. |
| 200 | All as per item No above but 80 mm bore, complete all as specified and directed. |
| 201 | Opening of leakage joints of 50 mm bore of Gl pipe and taking out unserviceable part like union tee elbow etc with provisioning of new materials complete all as specified and directed. |
| 202 | All as per item No above but 40 mm bore, complete all as specified and directed. |
| 203 | All as as per item No above but 25 mm bore, complete all as specified and directed. |
| 204 | All as per item No above but 20 mm bore, complete all as specified and directed. |
| 205 | S & F in replacement of 150 mm bore cast iron sluice valve with flanged end with stainless steel spindle and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer for following size ISI marked conforming to IS 14848 (2000), complete all as specified and directed. |
| 206 | S & F in replacement of 100 mm bore cast iron sluice valve with flanged end with stainless steel spindle and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer for following size ISI marked conforming to IS 14848 (2000), complete all as specified and directed. |
| 207 | S & F in replacement of 80 mm bore cast iron sluice valve with flanged end with stainless steel spindle and Cl wheel class PN 1.6 inc rubber gasket nuts bolts and washer for following size ISI marked conforming to IS 14848 (2000), complete all as specified and directed. |
| 208 | Taking up worn out cast iron of 100 mm bore water mains (Including all fittings) with spigot & Socket ends and lead joints inluding burning out joints and recovering lead complete all as complete all as directed. |
| 209 | Taking up worn out cast iron of 150 mm bore water mains (Including all fittings) with spigot & Socket ends and lead joints inluding burning out joints and recovering lead complete all as complete all as directed. |
| 210 | Supply and lay/Joint ductile iron pipe of 100 mm bore with both side flanged heads centrifugally cast class \\"A\\" in any length laid in treches ISI marked all as specified and directed ahnd taking out old one |
| 211 | Supply and lay/Joint ductile iron pipe of 150 mm bore with both side flanged heads centrifugally cast class \\"A\\" in any length laid in treches ISI marked all as specified and directed ahnd taking out old one |
| 212 | M&L for 50 mm bore GI tube medium grade ISI marked with necessary GI fitting such as elbow, union, reducer, tees, bends etc and short length complete laid in trenches/fixed on walls/ laid under floors including taking down of old unserviceable tubing all as specified and directed by Engr-in-charge |
| 213 | M&L for 40 mm bore GI tube medium grade ISI marked with necessary GI fitting such as elbow, union, reducer, tees, bends etc and short length complete laid in trenches/fixed on walls/ laid under floors including taking down of old unserviceable tubing all as specified and directed by Engr-in-charge |
| 214 | M&L for 25 mm bore GI tube medium grade ISI marked with necessary GI fitting such as elbow, union, reducer, tees, bends etc and short length complete laid in trenches/fixed on walls/ laid under floors including taking down of old unserviceable tubing all as specified and directed by Engr-in-charge |
| 215 | M&L for 20 mm bore GI tube medium grade ISI marked with necessary GI fitting such as elbow, union, reducer, tees, bends etc and short length complete laid in trenches/fixed on walls/ laid under floors including taking down of old unserviceable tubing all as specified and directed by Engr-in-charge |
| 216 | Cutting of road/hard standing for laying/dismentling of pipe line and making good disturbed surface and matching with the existing surface after laying of pipe line, complete all as specified and directed. |
| 217 | Supply & fixing 20mm bore gun metal gate valve with iron wheel head screwed both side for GI pipe following sizesand taking out old one |
| 218 | Supply & fixing 25mm bore gun metal gate valve with iron wheel head screwed both side for GI pipe following sizesand taking out old one |
| 219 | Supply & fixing 40mm bore gun metal gate valve with iron wheel head screwed both side for GI pipe following sizesand taking out old one |
| 220 | Supply & fixing 50mm bore gun metal gate valve with iron wheel head screwed both side for GI pipe following sizesand taking out old one |
| 221 | M&L for repairing cast iron Sluice valve 80mm flanged type of any make by dismantling the valve replacing the bolts nuts, washers, gaskets, spindle, wedgenut hand wheel set screw etc and reassembling and refixing the same in position including repairing the worn out galnd packing and testing conplete all as specified and directed. |
| 222 | M&L for repairing cast iron Sluice valve 100mm flanged type of any make by dismantling the valve replacing the bolts nuts, washers, gaskets, spindle, wedgenut hand wheel set screw etc and reassembling and refixing the same in position including repairing the worn out galnd packing and testing conplete all as specified and directed. |
| 223 | M&L for repairing cast iron Sluice valve 150mm flanged type of any make by dismantling the valve replacing the bolts nuts, washers, gaskets, spindle, wedgenut hand wheel set screw etc and reassembling and refixing the same in position including repairing the worn out galnd packing and testing conplete all as specified and directed. |
| 224 | S&F in repair bib tap standard of PTMT any colour high pressure screwed for iron pipes 15 mm dia (Minimum weight 90 gms) complete all as specified and directed. |
| 225 | M&L for Cutting of CI/DI pipes of 150 mm bore in position for insertion of new tees, branches etc including diverting due to residual water in pipes complete all as specified and directed by EIC. |
| 226 | M&L for Cutting of CI/DI pipes of 100 mm bore in position for insertion of new tees, branches etc including diverting due to residual water in pipes complete all as specified and directed by EIC. |
| 227 | M&L for Cutting of Cast iron pipes of 80 mm bore in position for insertion of new tees, branches etc including diverting due to residual water in pipes complete all as specified and directed by EIC. |
| 228 | M&L Flusing of borewell with compressed air with air compressor completely till the removed of sand, mud from the bore and till the clear water arrived . Flushing will be done with interval of 2-4 hours to the satisfaction of Eng-in-charge |
| 229 | Material and labour for repairs/servicing of chlorination Dozing plant/system having discharge flow upto 10LPH with discharge pressure Kg/Cm2 single phase electrically operated 230 volts , 50 HZ ,fuse 1 amp with plastic suction and delivery piping solution tank, two dosing tanks (01 working and 01 Standby), two electronic dosing pump (Auto 4 to 20mA) (01 working and 01 Standby) including replacement of unserviceable spares and recommissing and testing after repair complete all a specified. |
| 230 | S&F in repair Gear motor complete 230 Volt 50Hz for Dozing pumps , complete all as specified and directed. |
| 231 | S&F in repair Motor assembling with bearing brackets and Tolerance Dosing pumps complete all as specified and directed. |
| 232 | S&F in repair Coil 250 Volt 50 Hz for Dozing pumps, complete all as specified and directed. |
| 233 | S&F in repair Single head feed rate control with Dosing pumps complete all as specified and directed. |
| 234 | S&F in repair Pump tubing of size ⅜ inch white suction/discharge for Dosing pumps complete all as specified and directed. |
| 235 | S&F in replacement of hand wheel for opening and closing of sluice valve etc all as specified and directed of Eng-in-charge. |
| 236 | S&F in repairs notice board (in replacement) of size 120x90 Cm wooden frame cork notice bulletin board with pine wood finish frame as per sample all as specified and directed. |
| 237 | Material and labour painting with two coats of synthetic enamel paint over a coat of red oxide metal primer after preparation of external surface of pressed steel tanks/ladders/raising mains, delivery mains, wash out and overflow pipe line of OH reservoir/IRP's by scrapping of existing paint all as directed including arrow mark showing water flowing direction. |
| 238 | Checking of unserviceable Window/split AC/Water Cooler/Desert Cooler U/S parts likewise relay,compressor,blade,motor, gas leakage,condensor coil,capacitor,Thermostate,Filter,PCB,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs (b) The contractor or his representative will take complaint from MES complaint Register through MES job card.(c)The contractor will made seprate items register with location and signature of user . (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature.(e) The ladder and T&P as required will be provided by the contractor . (f) Risk Factor will be the contractor 's end. |
| 239 | supply only Compressor suitable for window/Split AC of capacity 1.5 Ton complete |
| 240 | supply only Capacitor of capacity 40/45 MFD |
| 241 | supply only Capacitor of capacity 55/60 MFD |
| 242 | supply only Capacitor of capacity 50+4 MFD |
| 243 | supply only Cooling Coil suitable for 1.5 Ton Capacity Split AC |
| 244 | supply only Swing motor blades suitable for 1.5 Ton Capacity Split type Air Conditioner as per existing sample |
| 245 | supply only Over load relay suitable for 1.5/2.0 Ton Split type AC |
| 246 | supply only PVC Front gril suitable for Window type AC of any Make suitable for 1.5/2.0Ton window AC |
| 247 | supply only Blower motor fan blade suitable for 1.5/2.0 Split type AC |
| 248 | supply only Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC |
| 249 | supply only Thermostat switch with knob suitable for AC of any capacity. |
| 250 | supply only Air Filter Suitable for 1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner |
| 251 | supply only Capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner |
| 252 | supply only PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 split type capacity Air Conditioner . |
| 253 | supply only PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 Split type capacity inverter type Air Conditioner |
| 254 | supply only Metal top with bottom suitable for 16 Amps Capacity 1.5/2.0 Ton Capacity Air conditioner Make: Anchor/Havells/Philips/polycab and as per site requirement. |
| 255 | supply only Suction/Drain out pipe suitable for 1.5/2.0 ton capacity Suitable for Air conditioner as per sample complete |
| 256 | supply only Insulation of size 1/4, 3/8 for Split AC complete as per existing sample |
| 257 | supply only Insulation of size 1/2 5/8 for Split AC complete as per existing sample |
| 258 | supply only Copper Tube of size 1/4/ 3/8 suitable for any type and any capacity Air conditioner as per existing sample |
| 259 | supply only Copper Tube of size 1/2 /5/8 suitable for any type and any capacity Air conditioner |
| 260 | supply only Plug nut of size 1/4 3/8 suitable for any type and any capacity Air conditioner |
| 261 | supply only Plug nut of size 1/2 5/8 suitable for any type and any capacity Air conditioner |
| 262 | supply only AC indoor AC unit back plate siitable for 1.5/2./3.0 Ton capacity Air conditioner |
| 263 | supply only Power relay Contactor suitable for 1.5 Ton AC |
| 264 | supply only Refrigerent Gas R-22 |
| 265 | supply only Refrigerent Gas R-32 ( C) |
| 266 | supply only Refrigerent Gas R-134(a)/R-600a |
| 267 | supply only NRV Suitable for Any Capacity& any Make Air conditioner |
| 268 | M&L for dismentelling of indoor and outdoor unit and disconnect the electric and gas connection ,cleaning the internal and portion of split AC indoor and outdoor unit checking serviceability transport to new location and fixing the indoor and outdoor unit connect gas and electric connection testing and commissioning complete all as specified and directed by engr-in-charge.Note:- rate shall be deemed included outdoor stand, copper tube alongwith insulation,cable as per site requirement any size any length.point wiring shall be measured sepretely. |
| 269 | Checking of unserviceable Water Cooler U/S parts likewise relay,compressor,blade,motor, gas leakage,condensor coil,capacitor,Thermostate,Filter,PCB,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs (b) The contractor or his representative will take complaint from MES complaint Register through MES job card.(c)The contractor will made seprate items register with location and signature of user . (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature.(e) The ladder and T&P as required will be provided by the contractor . (f) Risk Factor will be the contractor 's end. |
| 270 | supply only Compressor suitable for 60/120 Water cooler capacity |
| 271 | supply only Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
| 272 | supply only Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
| 273 | supply only Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
| 274 | supply only Thermostat switch with knob suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
| 275 | supply only Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacity as per sample Make: Waterman/Leader |
| 276 | supply only Air Filter Suitable for water cooler 150/180,60/120 and 40/80 capacity |
| 277 | supply only PVC Drain out pipe as per sample |
| 278 | M&L for water cooler Stainless storage tank brazing/welding of damage/crack portion and making good condition including replacement of Bolt,nut with washers and testing complete |
| 279 | Checking of unserviceable REFRIGERATOR parts likewise relay,compressor,blade,motor, gas leakage,condensor coil,capacitor,Thermostate,Filter,PCB,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs (b) The contractor or his representative will take complaint from MES complaint Register through MES job card.(c)The contractor will made seprate items register with location and signature of user . (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature.(e) The ladder and T&P as required will be provided by the contractor . (f) Risk Factor will be the contractor 's end. |
| 280 | supply only Compressor suitable for 260 to 310 Ltrs Capacity Refrigerator |
| 281 | supply only Magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator as per sample (Double Door) |
| 282 | supply only Freezer suitable for 286/310 Ltrs capacity Refigerator |
| 283 | supply only Relay current type and over load protector suitable for compressor complete Make: Ranutrol/Voltas/LG |
| 284 | supply only Thermostat auto defrost type suitable for any make and any capacity Refrigerator |
| 285 | supply only Vegitable tray with Glass cover and bottle rack as per sample and suitable for refrigertator any type and any make |
| 286 | supply only Contensor Coil suitable for any model and capacity Refrigerator as per sample |
| 287 | supply only Evaporator Coil suitable for any model and capacity Refrigerator as per sample |
| 288 | supply only Expansion valve suitable for any model and capacity Refrigerator as per sample |
| 289 | Checking of unserviceable DEEP FREEZER U/S parts likewise relay,compressor,blade,motor, gas leakage,condensor coil,capacitor,Thermostate,Filter,PCB,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs (b) The contractor or his representative will take complaint from MES complaint Register through MES job card.(c)The contractor will made seprate items register with location and signature of user . (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature.(e) The ladder and T&P as required will be provided by the contractor . (f) Risk Factor will be the contractor 's end. |
| 290 | supply only Compressor Suitable for 300 Ltrs Capacity Deep Freezer |
| 291 | supply only Thermostat auto defrost type suitable for any make and any capacity Deep Freezer Make: Danfos/Ind Foss/renutrol or equivalent |
| 292 | supply only Drier filter complete set suitable for any make and any capacity Deep Freezer |
| 293 | supply only Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity |
| 294 | supply only Starting relay suitable for 310/320 ltrs capacity Deep freezer |
| 295 | supply only Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer Make; AUE/Cool Blow/Universal or equivalent |
| 296 | supply only Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer |
| 297 | Checking of unserviceable Desert Cooler U/S parts likewise blade,motor ,capacitor,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs (b) The contractor or his representative will take complaint from MES complaint Register through MES job card.(c)The contractor will made seprate items register with location and signature of user . (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature.(e) The ladder and T&P as required will be provided by the contractor . (f) Risk Factor will be the contractor 's end. |
| 298 | supply only Fan motor of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC supply confirming to IS-996/79 (motor only) with mounting accessories Make- Khaitan/Cool Blow/CG/Bajai |
| 299 | supply only Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr Make:indo/summer cool |
| 300 | supply only Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size |
| 301 | supply only PVC Flexible hose suitable for desert cooler cooling system |
| 302 | supply only PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample |
| 303 | supply only Selector switch as per existing model & size and three varient speed control |
| 304 | supply only Bolt, nut with washers as per sample |
| 305 | supply only PVC Connector i.e (Elbow, Tee,4 way etc) |
| 306 | supply only Front Panel as per existing size and model |
| 307 | supply only PVC swirtch box as per sample and size |
| 308 | supply only GI Chicken Mesh |
| 309 | supply only PVC Insulated copper conductor and PVC over all coverd cord cable copper conductor 3 core of size 2.5 Sqmm make :Plaza/Havells/ Finolex Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender