Tender For repair maintenance Electrical & Mechanical Services In Residential Building At Lok Niwas Marg & Surender Singh Lane Under M-4512. (Sh:-Routine, Operation And Maintenance Of Electrical & Mechanical Services At 8 Lok Niwas Marg & Surender Si
Tender Overview
Project Description
Tender for repair maintenance Electrical & Mechanical Services In Residential Building At Lok Niwas Marg & Surender Singh Lane Under M-4512. (Sh:-Routine, Operation And Maintenance Of Electrical & Mechanical Services At 8 Lok Niwas Marg & Surender Singh Lane)
BOQ
| Sl. No. | Item Description |
| 1 | Routine maintenance and attending day to day complaints of electrical installations, distribution boards, electrical panel board and compound light / street lights including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation and for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works, as and when required and recording reading in log book & allied accessories & keeping the entire installation on functional mode by deploying following staff in various shifts on all days of the month including Sunday & Holiday, as per terms & conditions attached and as per direction of Engineer-in-charge etc. as required.(a) Wireman - 4 Nos. (1 No in round the clock) & (1 no in general shift)(b) Khallasi - 4 Nos. (1 No. in round the clock) & (1 no in general shift) |
| 2 | Running maintenance & operation and general upkeep & cleaning of various capacity DG Sets & pump set comprising of engine, alternator with auto start panel /AMF Panel & allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including periodical checking of DG set for their proper functioning along with minor repair works, as and when required and recording reading in log book by deploying staff in various shifts on all days of the month including Sunday & Holiday, as per terms & conditions attached and as per direction of Engineer-in-charge etc. as required.(a) DG Set Operator - 3 Nos. (1 No. in round the clock) |
| 3 | Routine maintenance and attending day to day complaints of electrical installations, distribution boards, electrical panel board and compound light / street lights including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation and for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works, as and when required and recording reading in log book & allied accessories & keeping the entire installation on functional mode by deploying following staff in various shifts on all days of the month including Sunday & Holiday, as per terms & conditions attached and as per direction of Engineer-in-charge etc. as required.(a) Wireman-cum-Operator - 3 Nos. (1 No. in round the clock) |
| 4 | Providing services of High Skilled Supervisor for assignment & arrangement of the labour at site, according to duty chart as per terms & conditions and supervise the labour which are engaged to attend the day-to-day complaints and report the status of same & major issues, maintain and record the daily attendance, monthly wages, subscription ESI/EPF, providing & distribution of complaint register, log book, tools, cleaning agents, leveries, worker diary, uniform etc. to site labour with checking on daily basis including submission of all the records as per terms & conditions and direction of Engineer-in-charge complete with maintain proper decorum of site as required. |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a)3 x 1. 5 sq. mm |
| 6 | b) 3 x 2. 5 sq. mm |
| 7 | c) 3 x 4 sq. mm |
| 8 | d) 3 x 6 sq. mm |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 A switch |
| 10 | b)15/16 A switch |
| 11 | c) 6 pin 15/16 A socket outlet |
| 12 | d) Telephone socket outlet |
| 13 | Supplying and fixing following size/ modules, PVC/GI box along with modular base & cover plate for modular switches in recess etc as required.a)1 or 2 Module (75mmX75mm) |
| 14 | b)3 Module (100mmX75mm) |
| 15 | c)4 Module (125mmX75mm) |
| 16 | d)6 Module (200mmX75mm) |
| 17 | e)8 Module (125mmX125mm) |
| 18 | f)12 Module (200mmX150mm) |
| 19 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole |
| 20 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.a) 250 Amp, 35 KA, TPMCCB |
| 21 | b) 100 Amp, 16 KA, TPMCCB |
| 22 | c) 400 Amp, 35 KA, TPMCCB |
| 23 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)36 watt |
| 24 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)36 watt |
| 25 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/ 4000°K/ 5700°K/ 6500°K (As per ANS Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 100 watt |
| 26 | b) 150 watt |
| 27 | LED Flood Light, powder coated pressure die cast aluminum body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 150 watt |
| 28 | b) 200 watt |
| 29 | Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 30 | Supplying, installation, testing and commissioning of 400 mm sweep size wall mounted fan complete with inbuilt electronic regulator, blade, wire lead with moulded plug top etc. as required. |
| 31 | Supplying and installation of following size fresh air fan of plastic body suitable for 220 volts, 50 hz, AC supply, in the existing opening including making the hole to suit the size of the fan & making good the damages complete with connection, testing & commissioning etc. as required.(a) 250 mm sweep size |
| 32 | Supplying and fixing of 11 Fins Oil Filled Room Heater (ISI marked) with Min-1000W, Med-1300W, Max-2400W, adustable thermostat, PTC heating element, over heat protection, castor wheels suitable for operation on 230V, 50Hz, single phase AC supply complete with testing & commissioning etc. as required. |
| 33 | Supplying and fixing of 1200 watt revolving room heater having 3 Nos halogen rod, made out of CRCA/plastic body with effective cord length, CRCA heat reflector, crome plating, dual safety assurance, suitable for operation on 230V, 50Hz, single phase AC supply complete with testing & commissioning etc. as required. |
| 34 | Supplying and fixing of Fan Room Heater with 2 positions of wattage Min-1000W to Max-1800W, adjustable thermostat for temperature control, thermal cut out for overheating protection, tip over protection, suitable for operation on 230V, 50Hz, single phase AC supply complete with testing etc. as required. |
| 35 | Supplying and laying of 3 x 4 sq.mm XLPE insulated & PVC sheathed copper conductor unarmoured flexible power cable of 1.1 KV grade on surface etc. as required. |
| 36 | Less for credit of old dismantle material like copper wire, conduit, box, MCB, MCCB, fans, light fitting etc. under buyback arrangement. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender