Heavy Industries and Public Enterprises Boards / Undertakings / PSU Closing in 4 days TDR #57193251

Tender For Construction Of New Building For Jak Elamkunnu Kottayam

Issued by Boards / Undertakings / PSU · Kottayam, Kerala
Tender Value
42.13 Lakhs
Estimated cost
Bid Submission
04 Sep 2026
4 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of New Building For Jak Elamkunnu Kottayam

BOQ

Name of Work:- CONSTRUCTION OF NEW BUILDING FOR JAK ELAMKUNNU KOTTAYAM
Sl. No. Item Description
1CIVIL WORKS
2DISMANTILING AND DEMOLISHING WORKS
3Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
4SITE CLEARANCE
5Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
6EARTH WORK AND EXCAVATION
7Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, including gettingout the excavated soil and disposal of surplus excavated soil as directed, within a leadof 50 m.All kinds of soil
8Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m
9Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)3
11Providing and laying in position ready mixed concrete manufactured in BIS certified plants and transported to site of work in transit mixer for a lead of 15kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per IS9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. Minimum cement content shall satisfy exposure conditions but not less than 330kg/m3. (The entire process such as mixing, transit, pumping, laying and consolidation etc shall be completed within 2hrs. The quality of concrete such as strength and workability is to ensured at site by conducting appropriate tests by the site Engineer concerned. Charges if any conducting tests etc is to be born by the contractor)M25 grade of concrete
12Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
13Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more
14Providing and fixing of expansion joint system of approved make and manufacturesfor various roof locations as per approved drawings and direction of Engineer-InCharge. The joints shall be of extruded aluminum base members with, self aligningand self centering arragement support plates asper ASTM B221-02. The systemshall be such that it provides watertight roof to roof/roof to corner joint coverexpansion control system that is capable of accommodating multidirectionalseismic movement without stress to its components. System shall consist of metalprofile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shallbe designed of width and thickness required to satisfy movement and loadingrequirements and secured to base members by utilizing manufacturer’s preengineeredself-centering arrangement that freely rotates / moves in all directions.The Self centering arrangement shall exhibit circular sphere ends that lock andslide inside the corresponding aluminum extrusion cavity to allow freedom ofmovement and flexure in all directions including vertical displacement. The JointSystem shall resists damage or deterioration from the impact of falling ice, exposureto UV, airborne contaminants and occasional foot traffic from maintenancepersonnel. Provision of Moisture Barrier Membrane in the Joint System to havewater tight joint is mandatory requirement. Material shall confirm to ASTM6063.Roof Joint of 100 mm gap.
15Providing and filling in position, blow bitumen in expansion joints.
16CENTERING AND SHUTTERING
17Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
18Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform
19Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers
20Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
21Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges
22Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc.
23STONE WORK
24Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand)
25MASONRY WORK
26Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) includingcost of scaffolding complete
27Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etccomplete.
28Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part 1 of 1979 for foundation andplinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
29PLASTERING
3012 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
316 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
32DOORS AND WINDOWS
33Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood
34Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper
35Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size)
36Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressedbutt hinges bright finished of required size with necessary screws. ( Shutter area to bemeasured)
37Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm
38Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm
39Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge.
40Providing and fixing to existing door frames24 mm thick factory made PVC doorshutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and railsmitred and joint at the corners by means of M.S. galvanised/plastic brackets of size75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles ofthe shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm(± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollowsection of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutterstyles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with auPVC multi-chambered single panel of size not less than 620 mm, having over allthickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled verticallyand tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod andfastened with nuts and washers, complete as per manufacturer's specification anddirection of Engineer-in-charge( For W.C. and bathroom door shutter).
41Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), withdouble speed adjustment with necessary accessories and screws etc. complete.
42Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance ±1 mm), with wall thickness2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized bracketsand stainless steel screws, joints mitred and plastic welded. The hinge side vertical ofthe frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturer's specification and direction of Engineer-in-chargeExtruded sectionprofile size 48x40 mm
43Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
44Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of I st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.25 mm thick (for cupboard ) including ISI markednickel plated bright finished M.S. piano hinges IS : 3818 marked with necessaryscrews
45Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm
46ALUMINIUM WORKS
47Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron)
48For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron)
49Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm)
50Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm
51STEEL WORKS
52Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.)
53TILE WORKS
54Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
55Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm infloors, jointed with neat cement slurry mixed with pigment to match the shade of thetiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement
56Providing and laying Vitrified tiles in different sizes (thickness to be specified by themanufacturer), with water absorption less than 0.08% and conforming to IS : 15622,of approved brand & manufacturer,in all colours and shade, in skirting, riser ofsteps, laid with cement based high polymer modified quick set tile adhesive (waterbased) conforming to IS : 15477, in average 6 mm thickness, including grouting ofjoints (Payment for grouting of joints to be made separately).Size of Tile 600x600mm
57Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
58Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm
59PAINTING
60Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm
61Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
62Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work
63Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete.
64PLUMBING
65Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid
66Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
67Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:20 mm nominal bore
68Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
69Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.15 mm nominal dia pipes
70Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes
71Providing and fixing CP Square gratings complete as per direction of engineer incharge
72Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete.
73Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour600 mm long towel rail with total length of 645 mm, width 78 mm andeffective height of 88 mm, weighting not less than 190 gms
74Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials withsnap fittings of approved quality and colour, weighing not less than 105 gms
75Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank.
76Supplying and fixing CP Health faucet good quality including cost of materials andlabour charges etc. complete as per the direction of site engineer-in-charge.
77Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall
78Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2
79Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer- in- Charge.Concealed work, including cutting chases and making good the wall etc. 15 mm pipe12 Kgf/ cm2
80Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2
81Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers
82Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10Kgf/cm2 - External work - Exposed on wall
83Flexible pipe40 mm dia
84Providing and fixing PTMT Waste Coupling for wash basin and sink, of approvedquality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadthweighing not less than 45 gms
85Providing and fixing PTMT extension nipple for water thank pipe, fittings ofapproved quality and colour .20 mm nominal bore, weighing not less than 40 gms
86Providing and fixing C.P brass long nose bib cock of approved quality conforming toIS standards and weighing not less than 810 gms.15 mm nominal bore
87Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe12 kgf/cm2
88Providing and fixing white vitreous china laboratory sink including making allconnections excluding cost of fittings:Size 600x450x200 mm
89Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparationof bed shall be paid separately) 4. 35 to 50 flush capacity
90Making soak pit 1.2 m diameter 3.0 metre deep with 45 x 45 cm dry brick honeycomb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete asper standard design. With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5
91SIGNAGES
92NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design,Supplying and fixing Name Board as per the technical specifications given -1 Inch GI pipe frame (16Guage) for Frame (Size proportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets (Aluminum Composite Panel) for Box area, 18mm thick Multi wood Lettering for Name Board as approved by<br> Engineer in charge.<br>For Measurement purpose, only area of ACP sheet to be measured
93Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete asper the per the direction of Engineer in charge. <br>
94ELECTRICAL WORKS
95POINT WIRING
96Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
97Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
98Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
99SUBMAINS
100Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
101Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
102Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
103PLUG POINTS
104Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
105Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
106Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
107Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
108Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
109Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
110Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
111Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
112Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
113Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
114Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
115Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
116Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
117Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
118Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
119Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
120Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
121POWER CIRCUITRY
122Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
123Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
124Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
125Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
126Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current up to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A, 4P, 30mA
127Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
128Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
129Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
130Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
131Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25amps DP Isolator complete with connections, testing and commissioning etc. as required
132Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
133CABLE SUPPLY, LAYING AND TERMINATION
134Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
135Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
136Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
137Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
138Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
139Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
140EARTHING
141Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
142Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG)
143Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
144FITTINGS
145SITC of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
146SITC of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 10 W LED light fixture (2 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 50 Lm/W, CRI 80 etc with all required accessories
147Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
148Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) including painting etc. as required.
149SITC of 10 W LED bulkhead luminaire that fits seamlessly in a variety of applications, lumen output greater than 1100 lumens with a system efficacy > 110 lm/W. The luminaire shall have a power factor > 0.9 and shall have 50,000 burning hours as per L70 criteria. The luminaire shall be BIS certified and shall comply all IEC safety requirements and test certificates of LM79 and LM80 reports shall be submitted. The luminaire shall housing shall be made of High Pressure die cast aluminum with a UV stabilized polycarbonate diffuser, IP66 and IK 09 protection, including all accessories necessary as required to complete installation.
150Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
151SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, 9\\" or 10\\" star rated as per BEE, with its all accessories including mounting as required for complete installation.
152SITC of Exhaust Fan Celling mounted type with flexible hose of required length and vent cowl as bird net, Make similar to Luker LXC 200mm 21W 1050RPM Tubular Ventilating Ceiling Mounted Fan or equivalent with its all accessories including mounting accessories.
153Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.Co2 type Fire Extinguisher, made from brand new seamless Steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge and mounted on Rubber Wheels / wall mounted brackets as per IS: 16018 specification, bearing ISI Mark. 4.5 Kgs
154CEILING FAN CLAMP
155Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
156Supply installation, testing and commissioning of following single phase to single phase UPS with battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with 30 min backup battery with, input pf>.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 2kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.
157TELEPHONE
158Supply of User Phone- Analog phone
159Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..Telephone socket outlet
160Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
161Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
162Supply, installation, testing and commissioning of Cat6 Information Outlet, RJ45 with all accessories required at site to complete the work as per technical specification
163Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
164Supply, Installation, Testing & Commissioning of 8 Port Network Switch with 8 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink
165SITC OF 4U Rack with PDU unit with Suitable for all type of DVR Box & Double DVR / Network Switch / Server Rack with 4 Power Socket & Cable , Tray (1No) - 1 Cooling Fan Lock & Key.
166Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
167DOCUMENTATION AND APPROVAL
168DOCUMENTATION AND APPROVAL - \\"Charges for Preparation of all drawings submitting and getting approval from KSEB, submitting of Completion certificates and arranging inspection, getting sanction from KSEB, obtaining power allocation if necessary & power connection including energy meter and metering cubicle etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts
169METER BOX CUBICLE TYPE FABRICATED: Supplying and Installing by testing and commissioning of 3 Phase 440 V, 50 Hz IEC standard Meter box Cubicle type, dust and vermin proof with wall mounting/ recess by cutting the wall / making good of damages/ color washing/ fixing directly to wall by Anchor bolts made of CRCA sheet metal powder coated with three numbers of HRA fuse carriers , Neutral din Bar, Earth din bar, Provision for mounting kWH Meter etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57193251
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 42.13 Lakhs
LAST DATE 04-09-2026
Authority
Authority Name Hll Lifecare Limited
Work Description Tender for Construction Of New Building For Jak Elamkunnu Kottayam
Basic Detail
Tender No HLL/CMO/HCD/JAK/ELK/KTY/26-27
Bidding Type Tender
Location
City Kottayam
State Kerala
Key Dates
Publish Date 25 Aug 2026
Submission Date 04 Sep 2026
Open Date 05 Sep 2026
Finance
Tender Value 42.13 Lakhs
Tender Fee 2950
EMD 50000
Exemption Not Available
Document List
5da68271-4578-473f-bd60-cc056b48e3dd.html
BOQ_1467032.xls
TEDOELK.pdf
Tendernotice_1 (12).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

5da68271-4578-473f-bd60-cc056b48e3dd.html

xls

BOQ_1467032.xls

pdf

TEDOELK.pdf

pdf

Tendernotice_1 (12).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders