Public Administrative Department Local Bodies Closing in 11 days TDR #57190747

Tender For Municipal Council Wanadongri Invite E-Tender For Year 2026-2027 (12 Months) For Street Light Arrangement, Supply & Erection Of Streetlight Octagonal Pole And Highmast Pole And Other Related Materials (As Per Pwd Csr Rate & Specification 20

Issued by Local Bodies · Nagpur, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
09 Sep 2026
11 days left
EMD
20000
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Municipal Council Wanadongri Invite E-Tender For Year 2026-2027 (12 Months) For Street Light Arrangement, Supply & Erection Of Streetlight Octagonal Pole And Highmast Pole And Other Related Materials (As Per Pwd Csr Rate & Specification 2022-23)

BOQ

Name of Work:- Municipal Council Wanadongri invite E-Tender for year 2026-2027 (12 months) for Street Light arrangement, Supply & Erection of Streetlight Octagonal Pole and Highmast Pole and Other related materials (As per PWD CSR rate & Specification 2022-23)
Sl. No. Item Description
1Street light arrangement, supply and erection of pole & other related materials ( as per PWD CSR rate & specification 2022-23 )
2Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-2)
3Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-3)
4Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (1-3-6)
5Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1100 V grade aluminum PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. (1-4-1)
6Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminum PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. (1-4-2)
7Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminum PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. (1-4-3)
8Supplying and erecting mains with WP 4 x 4 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. (1-4-6)
9Supplying and erecting mains with WP 4 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. (1-4-7)
10Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminum housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT up to 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2. (2-4-2)
11Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2 (2-4-3)
12Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-4)
13Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminum housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT up to 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-5)
14Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminum housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT up to 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-6)
15Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminum housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT up to 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-7)
16Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-8)
17Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2 (2-4-9)
18Supplying and erecting integrated LED street light fitting 130-140W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 15600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-10)
19Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-11)
20Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-13)
21Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-14)
22Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-15)
23Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-16)
24Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. (2-4-18)
25Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC (2-7-2)
26Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB (2-7-4)
27Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC (2-7-6)
28Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. (8-7-2)
29Supplying and erecting two pole metal clad changeover switch 240 V, 32 A erected on angle iron/GI frame and duly connected with suitable wire leads complete (5-1-9)
30Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (5-3-3)
31Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (5-3-2)
32Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (5-3-10)
33Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. (6-1-1)
34Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. (6-1-19)
35Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-4)
36Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-5)
37Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-6)
38Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-8)
39Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-9)
40Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-10)
41Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-11)
42Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-12)
43Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-14)
44Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-16)
45Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-17)
46Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-19)
47Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-22)
48Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-27)
49Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-28)
50Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-29)
51Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-30)
52Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-33)
53Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-34)
54Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-37)
55Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. (7-6-8)
56Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. (7-6-9)
57Supply and erecting 9m (clear height) Fixed type high-mast (Top-100mm, Bottom- 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. OH-PL/OPL (excluding luminaires). (8-2-8)
58Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL (8-2-12)
59Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL (8-2-13)
60Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL (8-2-15)
61Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm A/F, top 100 mm A/F on provided foundation as per specification no. OH-PL/OPL (8-2-17)
62Providing & erecting 10 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 175 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL (8-2-18)
63Providing & erecting 11 m high (clear height) galvanized octagonal pole with foundation bolts having bottom of 210 mm A/F, top 90 mm A/F on provided foundation as per specification no. OH-PL/OPL (8-2-19)
64Providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm A/F, top 90 mm A/F on provided foundation as per specification no. OH-PL/OPL (8-2-20)
65Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. (4-8-5)
66Providing and erecting galvanized 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT (8-2-21)
67Providing and erecting galvanized 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT (8-2-22)
68Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequatesize of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete. (8-2-23)
69Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete. (8-2-24)
70Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP (9-1-4)
71Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR (16-1-1)
72Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR (16-1-2)
73Excavating hard Rock or bituminous road by chiseling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (16-1-5)
74Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). (16-3-7)
75Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). (16-3-9)
76Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). (16-3-10)
77Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical GI pole). (16-3-11)
78Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). (16-3-12)
79Supplying and erecting ISI mark GI pipe 25 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP (16-5-3)
80Supplying and erecting ISI mark GI pipe 40 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. (16-5-5)
81Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. (16-5-6)
82Supplying & erecting single phase, 240V, street light control panel up to the max load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ CC foundation. (5-2-3)
83Supplying & erecting single phase, 240V, street light control panel up to the max load of 12kW, SPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. (5-2-4)
84Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. (5-2-5)
85Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. (5-2-6)
86Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA (9-1-6)
87Per Visit rates for the servicing work of 1 unit of Mahindra Company (25 KVA Model 3305 GM) self-start generator at the Municipal Council Office. This includes replacing the old engine oil and coolant with new ones, along with the replacement/provision of the oil filter, fuel filter, air filter, battery charging, software update, all other necessary materials, and servicing labor charges complete.
88Per Unit rates for the repairing work of 18 W LED Street Lights which includes replacing the old/defective LED Driver (Choke), LED Plate (MCPCB Chip), necessary wiring, and connectors with new ones, along with waterproofing/sealing, all other required materials and complete labor charges
89Per Unit rates for the repairing work of 24-30 W LED Street Lights which includes replacing the old/defective LED Driver (Choke), LED Plate (MCPCB Chip), necessary wiring, and connectors with new ones, along with waterproofing/sealing, all other required materials and complete labor charges
90Per Unit rates for the repairing work of 35-40 W LED Street Lights which includes replacing the old/defective LED Driver (Choke), LED Plate (MCPCB Chip), necessary wiring, and connectors with new ones, along with waterproofing/sealing, all other required materials and complete labor charges
91Per Unit rates for the repairing work of 45-50 W LED Street Lights which includes replacing the old/defective LED Driver (Choke), LED Plate (MCPCB Chip), necessary wiring, and connectors with new ones, along with waterproofing/sealing, all other required materials and complete labor charges
92Per Unit rates for the repairing work of 70-75 W LED Street Lights which includes replacing the old/defective LED Driver (Choke), LED Plate (MCPCB Chip), necessary wiring, and connectors with new ones, along with waterproofing/sealing, all other required materials and complete labor charges
93Per Unit rates for the repairing work of 110-120 W LED Flood Lights which includes replacing the old/defective LED Driver (Choke), LED Plate (MCPCB Chip), necessary wiring, and connectors with new ones, along with waterproofing/sealing, all other required materials and complete labor charges 1-5’’ Ench x 1-5 feet Long GI Pipe Brackets Single Bend with Fabrication Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57190747
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 09-09-2026
Authority
Authority Name Directorate Of Municipal Administration
Work Description Tender for Municipal Council Wanadongri Invite E-Tender For Year 2026-2027 (12 Months) For Street Light Arrangement, Supply & Erection Of Streetlight Octagonal Pole And Highmast Pole And Other Related Materials (As Per Pwd Csr Rate & Specification 2022-23)
Basic Detail
Tender No MCW/ED/2026/1967
Bidding Type Tender
Location
City Nagpur
State Maharashtra
Key Dates
Publish Date 25 Aug 2026
Submission Date 09 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 1500
EMD 20000
Exemption Not Available
Document List
555df952-9310-4691-8596-e4f78c1b59cb.html
BOQ_2279386.xls
Tendernotice_1 (65).pdf
Tender_Document.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

555df952-9310-4691-8596-e4f78c1b59cb.html

xls

BOQ_2279386.xls

pdf

Tendernotice_1 (65).pdf

pdf

Tender_Document.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders