Tender For Special Repair/Replacement Of Distribution Transformer Against Ber Transformer Under Age(E&M) Ge(Utility) Meerut
Tender Overview
Project Description
Tender for Special Repair/Replacement Of Distribution Transformer Against Ber Transformer Under Age(E&M) Ge(Utility) Meerut
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Sep-2026 | Amendment to date | Date | 10-Oct-2026 |
| 2 | 14-Sep-2026 | AMDT to date | Date | 29-Sep-2026 |
| 3 | 14-Sep-2026 | AMDT to date | Date | 29-Sep-2026 |
| 4 | 10-Oct-2026 | Amendment to Date 10 oct | Date | 24-Oct-2026 |
| 5 | 01-Oct-2026 | Amendment to Date | Date | 17-Oct-2026 |
| 6 | 14-Oct-2026 | AMENDMENT TO TENDER DOCS | Other | 28-Oct-2026 |
| 7 | 10-Oct-2026 | Amendment to Date 10 oct | Date | 24-Oct-2026 |
| 8 | 16-Oct-2026 | AMENDMENT TO DATE | Date | 28-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Commissioning of transformer (energy efficinet Level-3 transformer) of following cap , step-down outdoor type copper wound 11/0.433 KV (at no load), AC 3 phase 50 Hz, on secondary side double wound, oil immersed, naturally air-cooled with external cooling tubes/radiator, delta connected on primary and star connected with neutral brought out on secondary side. The transformer shall have tapping range +7.5% in steps of 2.5% each with vector Group Dyn11 to be changed by hand-operated OFF load tap changing gear. The maximum temperature rise should not exceed 45°C in oil and 50°C in H.V./L.V. winding when measured by the resistance method after continuous full load run. At ambient temperature, the transformer shall conform to IEC 60076 and IS 1180 Part-I 2014 or latest) and shall be complete with the following accessories:-(a) Three Nos. porcelain bushings with arcing horns on HV side suitable for 11 KV complete with bushing copper rods, nuts, and washers.(b) One cable box on LT side (secondary side) consisting of four Nos. porcelain bushings with copper rods, complete with nuts and washers, along with one No. cable gland suitable for receiving/taking out suitable size of LT cable, 1100 Volts grade PVC sheathed and PVC insulated heavy-duty armoured cable, including gland, jointing, and termination materials complete.(c) Oil conservator with filler hole, drain valve and oil level gauge along with .(d) Dehydrating breather with first fill dehydrating agent (silica gel).(e) Explosion vent.(f) Thermometer pocket on tank cover. |
| 2 | (g) One No. 100 mm dia dial type thermometer (vapour pressure type) having range 0–120°C with metal guard, having maximum temperature indication with resetting device for transformer.(h) Two earthing terminals on tank cover to facilitate fixing of 32×6 mm GI earth strip.(i) Rating plate and terminal marking plate.(j) Oil level gauge.(k) Oil drain filter valve.(l) Lifting lugs.(m) Oil filling hole with cap/plug with connection pipe complete.(n) Air relief valve plug.(o) 04 Nos. plain solid cast steel detachable rollers.(p) Breather assembly with silica gel with connected pipe first fill of dehydrant agent.(q) Extra bushing for neutral on LV side in cable box providing independent earthing for neutral. (r) First fill of fresh transformer oil conforming to relevant IS:335 ISI marked, filtered up to 60 kV dielectric strength at 2.5 mm gap.(s) WTI and OTI dial type as per OEM.Note : Factory visit will be crried out rep of accepting officer before dispatch of items.Pre-commisioning test will be carried out by SEI/AEI/EI before energing the transformer. |
| 3 | All description as per item No 1 but cap of transformer 250 KVA with 50% load losses less than equal to 864 W and with 100% load losses less then equal to 2488 W |
| 4 | All description as per item No 1 but cap of transformer 315 KVA with 50% load losses less than equal to 890W and with 100% load losses less then equal to 2440W |
| 5 | All description as per item No 1 but cap of transformer 400 KVA with 50% load losses less than equal to 1080W and with 100% load losses less then equal to 3214W |
| 6 | All description as per item No 1 but cap of transformer 500 KVA with 50% load losses less than equal to 1354 W and with 100% load losses less then equal to 3909 W |
| 7 | Supply, Installation, Commissioning of transformer (energy efficinet Level-3 transformer) of following cap , step-down outdoor type copper wound 11/0.433 KV (at no load), AC 3 phase 50 Hz, on secondary side double wound, oil immersed, naturally air-cooled with external cooling tubes/radiator, delta connected on primary and star connected with neutral brought out on secondary side. The transformer shall have tapping range +7.5% in steps of 2.5% each with vector Group Dyn11 to be changed by hand-operated OFF load tap changing gear.. The maximum temperature rise should not exceed 45°C in oil and 50°C in H.V./L.V. winding when measured by the resistance method after continuous full load run. At ambient temperature, the transformer shall conform to IEC 60076 and IS 1180 Part-I 2014 or latest) and shall be complete with the following accessories:-(a) Three Nos. porcelain bushings with arcing horns on HV side suitable for 11 KV complete with bushing copper rods, nuts, and washers.(b) One cable box on LT side (secondary side) consisting of four Nos. porcelain bushings with copper rods, complete with nuts and washers, along with one No. cable gland suitable for receiving/taking out suitable size of LT cable, 1100 Volts grade PVC sheathed and PVC insulated heavy-duty armoured cable, including gland, jointing, and termination materials complete.(c) Oil conservator with filler hole, drain valve and oil level gauge along with .(d) Dehydrating breather with first fill dehydrating agent (silica gel).(e) Explosion vent.(f) Thermometer pocket on tank cover. |
| 8 | (g) One No. 100 mm dia dial type thermometer (vapour pressure type) having range 0–120°C with metal guard, having maximum temperature indication with resetting device for transformer.(h) Two earthing terminals on tank cover to facilitate fixing of 32×6 mm GI earth strip.(i) Rating plate and terminal marking plate.(j) Oil level gauge.(k) Oil drain filter valve.(l) Lifting lugs.(m) Oil filling hole with cap/plug with connection pipe complete.(n) Air relief valve plug.(o) 04 Nos. plain solid cast steel detachable rollers.(p) Breather assembly with silica gel with connected pipe first fill of dehydrant agent.(q) Extra bushing for neutral on LV side in cable box providing independent earthing for neutral. (r) First fill of fresh transformer oil conforming to relevant IS:335 ISI marked, filtered up to 60 kV dielectric strength at 2.5 mm gap.(s) Buchlloz relay as per rating of transformer(t) Winding temperature indicator and Oil temperature indicatorNote : Factory visit will be crried out rep of accepting officer before dispatch of items.Pre-commisioning test will be carried out by SEI/AEI/EI before energing the transformer. |
| 9 | All description as per item No 2 but cap of transformer 750 KVA with 50% load losses less thanequal to 2015 W and with 100% load losses less then equal to 5323 W |
| 10 | All description as per item No 2 but cap of transformer 1000 KVA with 50% load losses less than equal to 2460 W and with 100% load losses less then equal to 6364 W |
| 11 | All description as per item No 2 but cap of transformer 1500 KVA with 50% load losses less than equal to 3753 W and with 100% load losses less then equal to 10821 W |
| 12 | All description as per item No 2 but cap of transformer 2000 KVA with 50% load losses less than equal to 4543 W and with 100% load losses less then equal to 13254 W |
| 13 | M&L in replacement of plate earthing for sub station equipments complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of LT equipments etc at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate excavation & earth work and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I. |
| 14 | M&L in replacement of GI plate earthing for TRANSFORMER NEUTRAL complete with COPPER PLATE 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl Copper earth strip 20 X 3 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of equipments etc at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate excavation & earth work and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I. |
| 15 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar complete all as specified and directed. |
| 16 | M&L for PCC in foundation(1:4:8) Cement concrete in foundation,filling and mass concrete complete all as specified & directed. |
| 17 | M&L for brickwork with subclass 'B' bricks,straight or curved on plan complete all as specified & directed. |
| 18 | M&L PCC (1:2:4) type B1 20 mm graded aggregate complete all as specified & directed. |
| 19 | Plaster in cement 15 mm (1:4) rendering 10 mm thick on fair face of brick work or concrete surface,Add or deduct/from the rates for rendering for each 5 mm thicness over or under 10mm,rendering is to be finished even and smooth, complete all as specified & directed. |
| 20 | M&L white wash 2 coate on wall preparing surfaces plasteered or unplastere, on wall complete all as specified & directed. |
| 21 | Excavating soft/loose over areas,n exc 1.5 deep and getting out complete all as specified & directed. |
| 22 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination,heat shrink type jopint complete with jointing matarial and accessories suitable for 3 core XLPE,armoured, Al conductor cable of size 95 sqmm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-8 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender