Tender For Provn Of Oxygen Pipeline System With Manifold For 419 Fd Hosp At R Ur Under Ge 969 Ews.
Tender Value
36.36 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
19 days left
EMD
72720
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Oxygen Pipeline System With Manifold For 419 Fd Hosp At R Ur Under Ge 969 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and averaging 15 cm in deep and getting out in any type of soil, complete all as specified and as directed. |
| 2 | Removal of surplus soil to a distance of 250m and not exceeding 500m and depositing, complete all as specified and as directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil, complete all as specified and as directed. |
| 4 | M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and as directed. |
| 6 | Removing excavated soil exc. 250 m but n exc. 500 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed. |
| 7 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering, complete all as specified and as directed. |
| 8 | M&L for hard core of broken stone or boulders of gauge n.exc.63mm deposited,spread,levelled in layers n.exc.15cm thickness,watered and rammed to a true surface, complete all as specified and as directed. |
| 9 | M&L for damp proof course to horizontal or vertical surface including necessary form work 40 mm thick in cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate, complete all as specified and as directed. |
| 10 | M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius with built in CM 1:6, complete all as specified and as directed. |
| 11 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4, complete all as specified and as directed. |
| 12 | M&L rendering 15mm thick on fair face of brick walls or concrete surfaces in CM 1:6 finished even and smooth without using extra cement, complete all as specified and as directed. |
| 13 | M&L for new plastered surfaces of walls and applying two coats of distemper oil emulsion over a one coat of primer and 3 mm wall putty complete all as specified and directed. |
| 14 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement based paint, complete all as specified and as directed. |
| 15 | Use and waste of form work to sides of foundation/footings, plinth beams and similar work for rough finished surfaces, complete all as specified and as directed. |
| 16 | Use and waste of form work to sides of columns and pillars for for fair finished surfaces, complete all as specified and as directed. |
| 17 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and as directed. |
| 18 | M&L for Reinforced Cement Concrete M-25 design mix controlled concrete (Using 20mm graded granite stone aggregate) in footings, plinth beams and the like, complete all as specified and as directed. |
| 19 | M&L for Reinforced Cement Concrete M-25 design mix controlled concrete (Using 20mm graded granite stone aggregate) in columns and pillars, complete all as specified and as directed. |
| 20 | M&L for Reinforced Cement Concrete M-25 design mix controlled concrete (Using 20mm graded granite stone aggregate) in lintel beams, roof beams lintle beams and the like, complete all as specified and as directed. |
| 21 | Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 22 | Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 23 | Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc cleats etc of GE 410 (Gde-E-250 quality-A), complete all as specified and as directed. |
| 24 | Plates (plain or chequered) channels, square cut or notched(ordinary and counter sunk) forming holes, without anyattachment of GE 410 (Gde-E-250 quality-A), complete all as specified and as directed. |
| 25 | S&F aluminium alloy powder coated aluminium door frame fixed with side hung shutters and glazing fixed with and including 5.50mm thick tinted glass fixed with rubber gasket with aluminium heading, clips frame made with aluminium box sec as appended below complete all as specified and directed including aluminium wire mess shutter.(a) Frame 100x44x1.48mm thick with rawl plug(b) Middle and lock rail : 150x44x1.48mm thick(c) Bottom rail : 100x44x1.48mm thick(d) Top rail/style : 100x44x1.48mm thick(e) Aluminium beading : 0.7mm thick(f) Aluminium handle D type 150mm long nos-02, aluminium tower bolt-02 9.9mm dia shoot 200mm long brass mortise lock 100mm 4 leaver aluminium stopper, hydraulically regulated designationed no-3 universal type of wt btn 61 to 80 kg-01(g) Making good of wall surface to match with existing surface complete. |
| 26 | S&F Powder coated aluminium sliding windows frame with movable shutter ( sliding on minimum two PVC roller of best quality, for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and incl 5.50 mm thick glass & stainless steel wire messs fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame :63x35mm X 1.48 mm thick for two tracks.(ii) Top/bottom rail and style / rail of shutter : 19x38x1.48mm thick and over. (iii) Aluminium beading - 0.7mm thick (iv) stainless steel wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium wire staples complete. (v) Aluminium fittings such aluminium suitable handle with auto interlocking closing(vi) Making good of wall surfaces to match with existing surfaces, complete all as specified and as directed. |
| 27 | M&L Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 28 | M&L Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 29 | M&L preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 30 | M & L for 100 mm thick Cement concrete type C- 2, 1:3:6 (20mm graded aggregate) in Plinth Protection and finishing surfaces of concrete in sub-floors, sub-bases,path etc.finished even and smooth without using extra cement, complete all as specified and as directed. |
| 31 | M&L Rubber Moulded interlocking paver block any shape and size confirming to IS 15658 -2006 of 80mm thickness, M-40 Grade with grey cement and no pigment, complete all as specified and as directed. |
| 32 | Excavation over area n exc. 1.5 m deep and getting out in hard/dense soil, complete all as specified and as directed. |
| 33 | M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in mass concrete, complete all as specified and as directed. |
| 34 | M & L for Walling of random rubble , uncoursed well bonded, bedded and solidly hearted built in CM 1:6, complete all as specified and as directed. |
| 35 | Extra over stone walling for hammer dressing to face stone and dressing of face beds and joints , complete all as specified and as directed. |
| 36 | M & L PCC 1:2:4 type B - 1 ( 20 mm graded aggregate) cast in situ as in coping, incl weathering slightly rounded and champhered angles and throating all as directed . |
| 37 | M&L for precast cement concrete 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in bond stones, complete all as specified and as directed. |
| 38 | M & L flush pointing to random rubble stone masonry in CM 1:4, uncoursed or brought upto courses, complete all as specified and as directed. |
| 39 | S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 40 | Removing excavated material n exc. 50 m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed. |
| 41 | Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and as directed. |
| 42 | M&L for Point wiring using proper colour coding complete with 1100 Volts grade 1.5 Sq.mm, single core, PVC insulated,unsheathed cable with multistranded copper conductor with ISI mark FRLS grade, conforming to IS-694 in and including PVC medium grade conduit/Casing Capping not less than 25mm dia. ISI marked with all accessories concealed in wall/ceiling/ floor /roof etc, sunk pressed steel/GI terminals boxes having 1.6 mm thick suitable for housing of modular type switches/sockets/fan regulators, including 1.5 Sq.mm PVC insulated, unsheathed, multistranded copper conductor, FRLS 1100 volts grade (green colour) as earth wire, connected to common earth dolly for:- |
| 43 | (a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 44 | (b) One 3 pin 5 Amp switch socket outlet on independent board |
| 45 | (c) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 46 | M&L for Point wiring using proper colour coding complete with 1100 Volts grade 2.5 Sq.mm, single core, PVC insulated, unsheathed cable with multistranded copper conductor with ISI mark FRLS grade, conforming to IS-694 in and including PVCmedium grade conduit/Casing Caping not less than 25mm dia. ISI marked with all accessories concealed in wall/ceiling/ floor /roof etc,with sunk pressed steel/GI terminals boxes having 1.6 mm thick suitable for housing of modular type switches/sockets/fan regulators, including 2.5 Sq.mm PVC insulated, unsheathed, multistranded copper conductor, FRLS 1100 volts grade (green colour) as earth wire, connected to common earth dolly for switch socket combination, 3 pin, 15 Amps on independent board all as specified and directed. |
| 47 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed |
| 48 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed. |
| 49 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete with gang box, complete all as specified and as directed. |
| 50 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete with gang box, complete all as specified and as directed. |
| 51 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 52 | S&F in repairs Distribution Board, SPN 8 Way, Double door , complete all as specified and as directed. |
| 53 | S & F in repairs MCB,DP 40 Amps 240 Volts B curve, complete all as specified and as directed |
| 54 | S & F MCB Single pole 6-32A Amps 240 Volts B Curve, complete all as specified and as directed. |
| 55 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 56 | M&L for Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in sevice connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire, with two single core cables flat or circular 16 sqmm 2 core, complete all as specified and as directed. |
| 57 | Supply and fix building security light LED fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with- 25 Nos IP 65/66 protection, complete all as specified and as directed. |
| 58 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and as directed. |
| 59 | Supply, installation, testing & commissioning of 4+4 Wall mounted Gas Manifold with NRV & Copper tail fabricated with High Pressure Copper of Size 5/8” X 10SWG and with IS319 Brass NRV Hydraulic tested at 300 Bar, Degreased Copper tail pipe of size 5/8” X 16 SWG Hydraulic tested at 300 Bar fitted on MS Frame middle frame with chain for Oxygen. (without cylinders), complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 60 | Supply, installation and commissioning of Semi-Automatic Control Panel (P. C) with inbuilt audio visual alarm & Non return valves for Oxygen with Copper tubing for connecting Manifold to control panel for both sides (Left Bank & Right Bank) complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 61 | Supply, installation, testing & commissioning of 1 Cylinder Emergency Wall mounted Gas Manifold with NRV & Copper tail fabricated with High Pressure Copper of Size 5/8” X 10SWG and with IS319 Brass NRV Hydraulic tested at 300 Bar, Degreased Copper tail pipe of size 5/8” X 16 SWG Hydraulic tested at 300 Bar fitted on MS Frame middle frame with chain for Oxygen and with Single stage double gauge MOX regulator -(Indian) (without cylinders) complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 62 | Supply, installation, testing & commissioning of British Standard NEMO SAFE gas outlets with stainless steel probe – Oxygencomplete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 63 | Supply, installation, testing & commissioning of Metal body BPC flow meter with humidifier bottle (0- 15 litres) Adult complete all as specified. HSN Code:-995415 Make :- MR |
| 64 | Supply and Fix Conversion Kit with 5 mtr High pressure tubing antistatic for Oxygen, complete all as specified and as directed. |
| 65 | Supply, installation, testing & commissioning of Vacuum pump (Simplex) with500ltr. Reservoir Tank, electrical motor (3phase) : * Base frame Vacuum pump 5 HP : 1 Nos. ( Make : AW / IR ) * Vacuum Receiver Tank 500 Ltr Capacity: 1 Nos.* Bacterial Filter * Silencer* Brass Fitting complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 66 | Supply, installation, testing & commissioning of British Standard NEMO SAFE gas outlets with stainless steel probe – Vacuum complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 67 | Supply and Fix Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with bracket complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 68 | Supply and Fix Low pressure tubing - Vacuum complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 69 | Supply, installation, testing & commissioning of MEDICAL Grade BS EN: 13348 LLOYD Tested COPPER PIPE (Indian) * Copper Pipe 12 mm OD X 0.7 mm thickComplete all as specified and as directed. HSN Code:-995415 Make :- Mexflow/Rajcom/Mandev |
| 70 | All as per item No. 69 above Copper Pipe 15 mm OD X 0.9 mm thick, complete all as specified and as directed. |
| 71 | All as per item No. 69 aboveCopper Pipe 22 mm OD X 0.9 mm thick, complete all as specified and as directed. |
| 72 | All as per item No. 69 aboveCopper Copper Pipe 28 mm OD X 0.9 mm thick, complete all as specified and as directed. |
| 73 | Supply, installation, testing & commissioning of LINE ISOLATION BALL VALVE, - (Indian) with both side End fittings : * 15mm* 22mm complete all as specified and as directed. HSN Code:-995415 Make :- RN/RB |
| 74 | All as per item No. 73 above Copper 22mm, complete all as specified and as directed. |
| 75 | Supply, installation, testing & commissioning of Microprocessor based Line Pressure Alarm- Digital type for 2 Gas Service (Oxygen / Vacuum) complete all as specified and as directed. HSN Code:-995415 Make :- MR |
| 76 | Supply, installation, testing & commissioning of Horizontal Bed Head panel – ENVIROM , 4 feet Long (MR-BHP-01) with powder coating and with the following provision : * Gas Outlet Points – 2 nos. (Provision )* Electrical Switches & Socket - 4 nos. each ( Not in our Scope )* Ward Vacuum Unit Slider * Stainless Steel Railing 2 feet Long complete all as specified and as directed. HSN Code:-995415 Make :- MR Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender