Banking and Finance Government Departments Closing in 34 days TDR #57188845

Tender For Design, Supply, Installation, Testing, And Commissioning (Dsitc) Of Cooling Tower For Banks Office Building At Fort, Mumbai

Issued by Government Departments · Mumbai, Maharashtra
Tender Value
68 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
34 days left
EMD
1.36 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Design, Supply, Installation, Testing, And Commissioning (Dsitc) Of Cooling Tower For Banks Office Building At Fort, Mumbai

BOQ

Name of Work:- Design, Supply, Installation, Testing, and Commissioning (DSITC) of Cooling tower for Banks Office Building at Fort, Mumbai
Sl. No. Item Description
1COOLING TOWERS1.1-Design, Supply, installation, testing and commissioning (DSITC) of Modular induced draft ,counter flow FRP cooling tower(CTI approved) of 500 TR capacity each(Energy Efficient & Low Noise)heat rejection capacity with FRP body and base, water spray headers, PVC fills, fan with direct driven motor(TEFC/ IE3 motor IP65 rating), fabrication of supporting GI base frames to be done on existing MS structural frame, inlet valve with float assembly, overflow with drain connection with valve and complete with fan, fan motor.Capacity shall be suitable for 3 X 400 TR chiller plant and above TR load as per ambient temperatures specified and technical specifications mentioned in tender part-1.(for further details please refer respective Item description in the NIT and Tender specification)
2Condenser Water Distribution System-2.1)Supply, laying, testing & commissioning of 'C' class heavy duty MS pipes(6 mm wall thickness) of approved makes with ISI mark for condenser water inlet , outlet and equaliser line with necessary clamp, support ,welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets,and fixing the pipe with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(for further details please refer respective Item description in the NIT and Tender specification)
3a)200 mm dia.
4b)100 mm dia.
52.2)Condenser pipeline coating-Supply & applying of high build Fiberglass Reinforced Plastics (FRP) condenser pipeline coating as detailed in technical specifications mentioned in the tender.
6a)350 mm dia
7b)200 mm dia
8C)100 mm dia
92.3)Valves without insulation-SITC of following valves, strainers, gauges of approved makes with water type cast iron body for PN16 pressure rating in the condensed water pipeline with the same specifications as the connected piping and adequately supported as per technical specifications mentioned in the tender.Price shall be inclusive of required flanges,nuts, bolts,welding, paint complete in all respects.(for further details please refer respective Item description in the NIT and Tender specification)
10a)Butterfly valve- SITC of following sizes of butterfly valves all complete with flanges, bolts, etc. as per technical specification mentioned in the tender.i)200 mm dia. manual valve
11a)Butterfly valve- SITC of following sizes of butterfly valves all complete with flanges, bolts, etc. as per technical specification mentioned in the tender.ii)100 mm dia. manual valve
12b) Ball valve for drain: SITC of 50 mm NB of ball valves for drain complete with required flanges, bolts, etc. as per technical specification mentioned in the tender
13c)Balancing valve-SITC of insulated balancing valve of size 200 mm dia. with built in measuring facility complete with insulated flanges, bolts, etc. as per technical specification mentioned in the tender
14d) Non-return valve (NRV) -SITC of insulated NRV of size 200 mm dia. complete with insulated flanges, bolts, etc. as per technical specification mentioned in the tender
152.4)Industrial Type Pressure Gauge(for further details please refer respective Item description in the NIT and Tender specification)
16SITC of Industrial type pressure gauge (0-10 Kg/sq.cm) with Syphon and valve and all mounting accessories as per technical specification mentioned in the tender.
172.5)Industrial Temperature Gauge(for further details please refer respective Item description in the NIT and Tender specification)
18SITC of Industrial type temperature gauge ( 0-50deg.C) with valve and all mounting accessories as per technical specification mentioned in the tender.
192.6)Suction Guide/ Strainer for Pumps(for further details please refer respective Item description in the NIT and Tender specification)
20SITC of Suction Guide/ Strainer of required size for cooling towers with all accessories as per technical specifications mentioned in the tender
212.7)Flexible pipe connectors(for further details please refer respective Item description in the NIT and Tender specification)
22Supply and fixing in position the following Flexible connection on pipes with guide bolts. ( Rubber Bellows ) suitable for PN 16 rating 200 mm NB
232.8)Miscellaneous(for further details please refer respective Item description in the NIT and Tender specification)
24a)SITC of Automatic Air vents - 25mm dia.
25b)SITC of Test point for measuring Pressure and temperature
26c)SITC of Condenser Water Line Flow Switch
27Electrical works-3.1)SITC of heavy duty XLPE insulated, FRLS PVC sheathed armoured, 1.1 KV grade aluminium/copper conductor cables on walls /ceiling/ trays as per site requirements including necessary hardware required for clamping namely spacers, saddles, screws, nuts, bolts, etc. Cable sizes should be as per technical specifications mentioned in the tender (for further details please refer respective Item description in the NIT and Tender specification)
28a)3 Core x 6 Sq.mm copper conductor Power cable with continuous two runs of 8 SWG GI earth wire with all support accessories.
29Electrical works 3.2)Supply and Installation of Standard double compression type cable glands made of Nickel Cadmium plated brass, heavy duty Aluminium/ Copper lugs palm type - crimping of lugs on each core of cable, providing ferrules on either end of cable and connection to the terminals in respective equipment for following cable sizes as per technical specification mentioned in the tender(for further details please refer respective Item description in the NIT and Tender specification)
30a) 3 Core x 6 Sq.mm copper conductor cable along with 8 SWG GI earth wire termination complete in all respect. Prices should include termiation at both ends.
31Electrical works 3.3)Cable Trays-Supply, installation of following sizes cable trays with 2 mm thickness perforated cable tray with GI thread rods and clamps as per technical specifications mentioned in the tender.(for further details please refer respective Item description in the NIT and Tender specification)
32150 mm x 50 mm x 2.0 mm Ladder Cable Tray
33Electrical works 3.4) Control power panel- Fabrication, supply, Installation, Testing & Commissioning of cubical type VFD cum Star- delta panel (wall mounted) conforming to technical specifications mentioned in the tender Part-I. Work includes termination of existing cables, control wires etc. with new panel. Work includes SITC of Modulating Inlet condenser water temperature, Outlet condenser water temp, controller/thermostat unit on each Cooling tower with suitable sizes of communication/control cables through PVC conduit pipes and required hardware etc. confirming to technical specifications mentioned in the tender Part-I and site conditions.(for further details please refer respective Item description in the NIT and Tender specification)
34VFD cum Star -Delta starter
354. Rebate for dismantling and taking away the old equipment under buyback scheme. Dismantling and taking away the existing chiller package consisting of the following equipment under buyback:(for further details please refer respective Item description in the NIT and Tender specification)
36a. Cooling tower Make: Advance -02 nos.(500 TR ) & Canara -01 no (400 TR), along with supporting GI structure
37b. Dismantling and taking away the existing condenser water pipings and their auxilliaries, connected to old cooling towers from main header lines etc
38c. Dismantling and taking away of existing power and control wires / cables including its accessories such as terminations, nut-bolts, insulation connected from starter panels to cooling towers etc.
39d. Starter panels
40e. Auxiliary parts such as various valves, strainers and other material that come out of the entire work Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57188845
AUTHORITY Government Departments
TENDER VALUE 68 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name reserve bank of india
Work Description Tender For Design, Supply, Installation, Testing, And Commissioning (Dsitc) Of Cooling Tower For Banks Office Building At Fort, Mumbai
Basic Detail
Tender No RBI/Mumbai Regional Office/Estate/26-27/ET/010
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 24 Aug 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 68 Lakhs
Tender Fee Ref. Documents
EMD 1.36 Lakhs
Exemption Not Available
Document List
BOQ_336422.xls
e1ff47eb-8c5c-4c3f-9ea0-3ad36f4d9987.html
TenderDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 34 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 35 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_336422.xls

html

e1ff47eb-8c5c-4c3f-9ea0-3ad36f4d9987.html

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders