Tender For Repair/Replacement Of Internal Fittings & Fixtures, Led And Tube Lights,Distribution Boards, Mcb And Connected Works In Domestic Area At Af Stn Ambala Under Ge (Af) Ambala
Tender Value
48.50 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
19 days left
EMD
97000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Internal Fittings & Fixtures, Led And Tube Lights,Distribution Boards, Mcb And Connected Works In Domestic Area At Af Stn Ambala Under Ge (Af) Ambala
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully aluminum point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, sketch fittings, tube light fittings, fan regulator, electric meters, meter box any type etc as directed by Engineer-in-Charge. Making good to the disturbed surface by plastering and two coat of distemper matching with existing surface, complete all as specifeid and directed. |
| 2 | M & L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19mm dia ISI marked and conduit accessories fixed concealed in wall with sunken type pressed steel/welded MS terminal boxes/modular metal flush box of suitable size made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of modular/piano type fittings,switches,sockets outlets,regulators etc complete including provisioning of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :- |
| 3 | One light/fan/controlled by one switch 6 amp one way complete all as specified and directed. |
| 4 | One 3 pin socket outlet 6 amp on the independent board complete all as specified and directed. |
| 5 | One 3 pin socket outlet on same board with other switches complete all as specified and directed. |
| 6 | One bell point controlled by one bell push complete all as specified and directed. |
| 7 | One light point controlled by two way switch complete all as specified and directed. |
| 8 | All as BOQ srl item No. 2.00 here-in-above described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed.Note: For item 3.00 to 8.00 The rate of chase cutting and making good the surface will be deemed in the rates quoted by the contractor. |
| 9 | M & L for point wiring in existing concealed conduit complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through existing conduit including provisioning of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete for the followings |
| 10 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 11 | One 3 pin socket outlet 6 amp on the independent board complete all as specified and directed. |
| 12 | One 3 pin socket outlet on same board with other switches complete all as specified and directed. |
| 13 | One bell point controlled by one bell push complete all as specified and directed. |
| 14 | One light point controlled by two way switch complete all as specified and directed. |
| 15 | All as per BOQ srl item No. 9.00 here-in-above described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed. |
| 16 | M & L for point wiring on wall/ surface in PVC conduit/ casing capping of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through PVC conduit/casing caping including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete for the following |
| 17 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 18 | One 3 pin socket outlet 6 amp on the independent board complete all as specified and directed. |
| 19 | One 3 pin socket outlet on same board with other switches complete all as specified and directed. |
| 20 | One bell point controlled by one bell push complete all as specified and directed. |
| 21 | All as per BOQ srl item No. 16.00 here-in-above described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed. |
| 22 | S&F in replacement switch modular type 5 amp single pole flush type one way of existing make complete all as specified and directed. |
| 23 | S&F in replacement switch modular type 15 amp single pole flush type one way of existing make complete all as specified and directed. |
| 24 | S&F in replacement modular step type fan regulator electronic type 120 watt 1 module of existing make complete all as specified and directed. |
| 25 | M&L in replacement socket outlet modular type 5 pin 5 amp multi pin flush type of existing make complete all as specified and directed. |
| 26 | M&L (in replacement ) socket outlet modular type 5 pin 15 amp multi pin flush type of existing make complete all as specified and directed |
| 27 | S&F in replacement modular cover plate with frame for 1 module of existing make complete all as specified and directed. |
| 28 | S&F in replacement modular cover plate with frame for 2 module of existing make complete all as specified and directed. |
| 29 | S&F in replacement modular cover plate with frame for 3 module of existing make complete all as specified and directed. |
| 30 | S&F in replacement modular cover plate with frame for 4 module of existing make complete all as specified and directed. |
| 31 | S&F in replacement modular cover plate with frame for 6 module of existing make complete all as specified and directed. |
| 32 | S&F in replacement modular cover plate with frame for 8 module of existing make complete all as specified and directed. |
| 33 | M&L in replacement switch piano flush type single pole, one way 6amp complete all as specified and directed. |
| 34 | M&L in replacement switch piano flush type single pole, two way 6amp complete all as specified and directed. |
| 35 | M&L in replacement switch piano flush type single pole, one way 15 amp complete all as specified and directed. |
| 36 | M&L in replacement socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed. |
| 37 | M&L in replacement socket outlet 2 in 1 , 3 pin 5 A and 15 A flush type complete all as specified and directed. |
| 38 | S&F in replacement ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed. |
| 39 | S& F in replacement lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed. |
| 40 | S&F in replacement bell push flush type 230 Volt complete all as specified and directed. |
| 41 | S&F in replacement call bell ding dong 230 V single phase complete all as specified and directed. |
| 42 | S&F in replacement socket type fan regulator electronic type complete all as specified and directed. |
| 43 | S&F in replacement gang box 3 module with modular 6 /16Amps switch and socket combination with necessary fitting complete all as specified and directed |
| 44 | S& F in replacement gang box piano type 6 /16 amps switch and socket combination with necessary fitting complete all as specified and directed |
| 45 | S& F in replacement gang box piano type 6 Amps switch and socket combination with necessary fitting complete all as specified and directed |
| 46 | S&F Box type LED tube light fitting 1x18 watt, 230 volts in commercial channel with powder coated CRCA sheet housing with including LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser connecting with twin core twisted flexible copper conductor cable of suitable size and taking down/out old unserviceable Tube Light fitting of any wattage. complete with all accessories all as specified and directed.Note : The LED fitting should Have input voltage 90-300V, luminaries efficacy > 100 lumen/watt |
| 47 | S&F LED tube rod 1x18 watt, 230 volts complete with all accessories and taking down/out old unserviceable tube rod of any wattage complete all as specified and directed.Note : The LED rod should Have input voltage 90-300V luminaries efficacy > 100 lumen/watt |
| 48 | S&F energy efficient slim type LED tube light fitting four feet 1x18 watt,box type, 230 volts and and taking down/out old unserviceable Tube Light fitting of any wattage complete with all accessories complete all as specified and directed. |
| 49 | S&F recess/Surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36 watt incl connecting with twin core twisted flexible copper conductor cable with suitable size and taking down/out old unserviceable recessess/ surface mounting fitting of any type/wattage. complete with all accessories complete all as specified and directed.Note : The LED fitting should Have input voltage 90-300V . luminaries efficacy > 100 lumen/watt |
| 50 | S&F LED batten with opal diffuser with inbuilt LED tube 10 watt 2 feet length and driver designed with high transmitting optics for even light distribution incl connecting with twin core twisted flexible copper conductor cable with suitable size and taking down/out old unserviceable Tube Light fitting of any wattage. complete with all accessories complete all as specified and directed.Note : The LED fitting should Have input voltage 90-300V, luminaries efficacy > 100 lumen/watt |
| 51 | S&F in replacement LED bulk head 10 watt with pressure die cast plasitc housing high efficient LEDs and enclosed with milky diffuser incl connecting with twin core twisted flexible copper conductor cable with suitable size any wattage complete with all accessories complete all as specified and directed.Note : The LED fitting should Have input voltage 90-300V, luminaries efficiency > 100 lumen/watt |
| 52 | S&F LED light fittings 45 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, operating temp -20 degree to 50 degree,color temperature 5700K, initial efficacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm from ceiling rose to fitting drawn through GI bracket and taking down/out old unserviceable building security light of any type / wattage complete all as specified and directed. |
| 53 | M&L for submain wiring in replacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall including PVC conduit and conduit accessories and incl provn of PVC insulated 4.0 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earthing point of DB box all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper matching with existing surfaces all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 4.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length complete all as specified and directed. |
| 54 | All as per BOQ srl item No 53.00 here-in- above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit 25 mm dia conduit medium grade complete all as specified and directed by Eng-in-Charge.Note: 02 runs of 06sqmm cable alongwith one run of 6.00 sqmm cable as earth wire conduit & conduit accessories will be measured as one unit for payment |
| 55 | M & L for sub main wiring in PVC casing and capping of reqd size 2 x 4.0 Sqmm PVC insulated multistrand copper conductor with 01x 4 Sqmm PVC insulated multistrand copper conductor as earth continuity wire complete all as specified and directed.Note: 02 runs of 04 sqmm cable alongwith one run of 4.00 sqmm cable as earth wire PVC casing & capping with accessories will be measured as one unit for payment |
| 56 | S&F in replacement recess mounting LED down light of 15 watt of existing make/model complete all as specified and directed. |
| 57 | S&F in replacement recess mounting low height bakelite round LED down light of 18 watt of existing make/model complete all as specified and directed. |
| 58 | S&F in replacement recess mounting low height bakelite square LED down light of 6 watt of existing make/model complete all as specified and directed. |
| 59 | S&F in replacement recess mounting low height bakelite square LED down light of 3 watt of existing make/model complete all as specified and directed. |
| 60 | S&F of New generation fancy type elegantly designed LED Wall mounted light B-22 base lamp including 7W warm white LED bulb and taking down/out old unserviceable any type/wattage of light fitting. complete all as specified and directed. |
| 61 | S&F of New generation fancy type elegantly designed LED Wall mounted light E-27 base lamp and input voltage 230 V AC, including warm white E-27 LED lamp and taking down/out old unserviceable any type/wattage of light fitting. complete all as specified and directed. |
| 62 | S&F LED garden light fitting with LED bulb upto 9 watt with clear acrylic cover in top section with IP 43 protection including all electrical connection with GI pipe light grade 40mm dia and up to 90 cm height including foundation and incl taking down old u/s any type/wattage of garden light fitting. complete all as directed by Engr in Charge. |
| 63 | S&F LED garden light fitting IP65 rated inverted pyramid tripod type LED bollard with soft 360 degree light distribution,input voltage 230 V AC,10Watt, including suitable PCC Foundation electrical connection and taking down old u/s any type/wattage of garden light fitting. complete all as directed by Engr in Charge. |
| 64 | S&F LED strip 1 watt flexible type warm white in colour 10 mm width including taking down the old one complete all as specified and directed |
| 65 | S & F in replacement LED bush light 6 watt (warm white) and input voltage 230 VAC , 50 Hz with cast aluminium housing with toughened glass IP-66 including fixing arrangement into wall/ pillar with necessary connection of suitable size of copper conductor cable complete all as specified and directed by Engr-in- charge at site. |
| 66 | S & F in replacement decorative LED post top lantern 25 Watt, indirect light with IP 65 protection ,resistant to impact and corrosion, glare free and better uniformity, input voltage 230 VAC , 50 Hz , including fixing arrangement like clamp nut bolts and washers and necessary connection of suitable size of copper conductor cable complete all as specified and directed by Engr-in- charge at site. |
| 67 | S & F in replacement Aesthetically designed LED post top lantern 15 Watt and input voltage 230 VAC , 50 Hz , with die cast aluminium spigot & prismatic diffuser , IP-65/66 including fixing arrangement like clamp nut bolts and washers and necessary connection of suitable size of copper conductor cable complete all as specified and directed by Engr-in- charge at site. |
| 68 | S & F in replacement Hylam Sheet of size 4X5 complete all as specified and directed. |
| 69 | S & F in replacement Hylam Sheet of size 8X5 complete all as specified and directed. |
| 70 | S & F in replacement Hylam Sheet of size 10X5 complete all as specified and directed. |
| 71 | S & F in replacement Hylam Sheet of size 8 x 10 complete all as specified and directed. |
| 72 | S & F in replacement Hylam Sheet of size 10X12' complete all as specified and directed. |
| 73 | S & F in repacement PVC round plate cover of size 4\\" to 6\\"complete all as specified and directed |
| 74 | S & F in replacement LED lamp 9 watt B-22 base complete all as specifed and directed |
| 75 | S & F in replacement LED lamp 7 watt B-22 base complete all as specifed and directed |
| 76 | S&F in replacement distribution board double door type(for incoming MCCB & outgoing MCBs) TPN 4 way vertical type loadline distribution board of 4 way incomer + 12 module outgoings sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring and duly flush in wall and making good disturbed surfaces complete all as specified and directed .Note : (i) MCCB shall be paid and measured separately under respective item of the schedule.. |
| 77 | S&F in replacement distribution board double door type(for incoming MCCB & outgoing MCBs) TPN 8 way vertical type loadline distribution board of 4 way incomer + 24 module outgoings sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring and duly flush in wall and making good disturbed surfaces complete all as specified and directed .Note: (i) MCCB shall be paid and measured separately under respective item of the schedule.. |
| 78 | S&F in replacement sheet metal enclosures for MCB distribution board 415 Volts three pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 79 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 80 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 81 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 12 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 82 | S&F in replacement MCCB Four pole 415 Volts, 100 A, 16 KA complete all as specified and directed. |
| 83 | S&F in replacement MCCB 63 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 84 | S&F in replacement MCCB 125 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 85 | S&F in replacement MCCB 160 Amp, 4 pole 25 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed. |
| 86 | S&F in replacement of off load change over switch 4 pole 415 volts 100 Amp rating with side handle including enclosure complete all as specified and directed. |
| 87 | S&F in replacement of off load change over switch 4 pole 415 volts 63Amp rating with side handle operated including enclosure complete all as specified and directed. |
| 88 | S&F in replacement automatic/ manual transfer switch conforming to IEC 60947-1 with inbuilt time delay,100A rating, 415V, 4P with sheet steel enclosure complete all as specified and as directed |
| 89 | S&F in replacement MCB three pole and neutral 415 Volts, 63 A, 10 KA complete all as specified and directed. |
| 90 | S&F in replacement MCBs 5 to 40 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 91 | S&F in replacement MCBs 5 to 32 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 92 | S&F in replacement plug top of 15 Amp capacity 240V, single phase including connection complete all as specifeid and directed. |
| 93 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earthing lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6) type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.Note : The Earth result should be less than 2 ohm and the result will be checked in presence of MES Rep, if desired earth reisstance is not found then entire earthing shall be re-done by contractor without accruing any extra cost to the Govt. |
| 94 | S&F, connecting & testing in replacement of sheet metal enclosures with plug top & socket including Single pole MCB 20 Amp, 240 Volts,10 KA complete all as specified & directed by Engineer-in-Charge. |
| 95 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core flat of size 6 sqmm solid aluminium conductor complete all as specified and directed. |
| 96 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core flat of size 10 sqmm solid aluminium conductor complete all as specified and directed. |
| 97 | S&F in replacement PVC insulated single core copper conductor of 1.5 sqmm complete all as specified and directed. |
| 98 | S&F in replacement PVC insulated single core copper conductor of 2.5 sqmm complete all as specified and directed. |
| 99 | S&F in replacement PVC insulated single core copper conductor of 6 sqmm complete all as specified and directed. |
| 100 | S&F in replacement PVC insulated single core copper conductor of 4 sqmm complete all as specified and directed. |
| 101 | S&F in replacement 2 core Flexible wire of 23/2 complete all as specified and directed. |
| 102 | S&F in replacement hot & cold water PVC flexible pipe connection from geyser and S&F new brass chromium plated water pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete all as specified and directed. |
| 103 | S&F in Replacement of heating element 2.0 KW for 25/35/50ltrs capacity of existing shape/size geyser ISI marked complete all as specified and directed. |
| 104 | S&F in Replacement of thermo static switch of geyser of existing make for 25/35/50 ltrs complete all as specified and directed. |
| 105 | M&L in Replacement of PVC insulated copper (flexible) conductor2.5 Sqmm 3 core complete all as specified and directed. |
| 106 | S&F PVC body air freshner230/ 250 mm sweep single phase 230 volts including louvers and fixing arrangement as per site requirement and complete all as specified and directed. |
| 107 | S&F ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1200mm sweep , Min air delivery 210CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as specified and directed. Please Enable Macros to View BoQ information |
| 108 | S&F ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1200mm sweep , Min air delivery 210CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender