Tender For Supply, Erection, Testing And Commissiong Of Main Lt Panel, Ht Vcb Panel And Ht Cables With Allied Items For Police Lines, Moginand Panchkula
Tender Value
66.51 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
12 days left
EMD
67000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Erection, Testing And Commissiong Of Main Lt Panel, Ht Vcb Panel And Ht Cables With Allied Items For Police Lines, Moginand Panchkula
BOQ
| Sl. No. | Item Description |
| 1 | [13.28]Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate] |
| 2 | [23.32.1.3]Automatic Power Factor Correction (APFC) SystemSupply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V plus 10 %, 50 Hz AC System for Ambient temperature -5°C to plus 40°C, fabricated in compartmentalized designed made of CRCA sheet steel of 2.0mm thick for framework and covers, 3 mm thick for gland plate i/c cleaning and finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminum alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 and 2) APFC Panel shall be in compliance with IS :16636 and CPWD Specifications etc. as per below details(A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.(B) Instruments and Indications i) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR and above) with Communication Ethernet/RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT`s accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.i) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.ii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V and I, Frequency.iii) Suitable rating control transformer shall be provided for control and indication circuit.i) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB`s.ii) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade, PVC insulated multi stranded copper control wire.(B) Bus Bars1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity 1.25 times of incomer rating as per CPWD specification.(C) Outgoings (APFC Section)Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor, the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and other features as per CPWD Specifications and relevant IS Code having following:(i) Capacitor bank ratings and stages shall be as per(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism.(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts.(iv) 14% Detuned Reactor of class H insulation and 150% linearity in series with Capacitor. 3. 100 KVAR [Rate] |
| 3 | [23.32.1.7]Automatic Power Factor Correction (APFC) SystemSupply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V plus 10 %, 50 Hz AC System for Ambient temperature -5°C to plus 40°C, fabricated in compartmentalized designed made of CRCA sheet steel of 2.0mm thick for framework and covers, 3 mm thick for gland plate i/c cleaning and finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminum alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 and 2) APFC Panel shall be in compliance with IS :16636 and CPWD Specifications etc. as per below details(A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.(B) Instruments and Indications i) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR and above) with Communication Ethernet/RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT`s accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.i) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.ii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V and I, Frequency.iii) Suitable rating control transformer shall be provided for control and indication circuit.i) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB`s.ii) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade, PVC insulated multi stranded copper control wire.(B) Bus Bars1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity 1.25 times of incomer rating as per CPWD specification.(C) Outgoings (APFC Section)Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor, the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and other features as per CPWD Specifications and relevant IS Code having following:(i) Capacitor bank ratings and stages shall be as per(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism.(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts.(iv) 14% Detuned Reactor of class H insulation and 150% linearity in series with Capacitor. 7. 200 KVAR [Rate] |
| 4 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 5 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 6 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 7 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 8 | [24.13.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate] |
| 9 | [24.16.3]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 3. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 70 Sq mm 3 core [Through Rate] |
| 10 | [24.16.4]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 core [Through Rate] |
| 11 | [24.16.6]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 6. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 150 Sq mm 3 core [Through Rate] |
| 12 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 13 | [24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate] |
| 14 | [24.3.3.2]HT CABLE 3.2. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 to 185 sqmm [Through Rate] |
| 15 | [24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate] |
| 16 | [24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm [Through Rate] |
| 17 | [24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate] |
| 18 | [24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia [Through Rate] |
| 19 | [24.7]RCC FOUNDATIONS FOR DG SET \\"Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1.8x1.0m)\\" Unit: per cum [Through Rate] |
| 20 | MAIN LT PANELSupply and Erection Testing and commissioning of indoor type TTA LT PANEL with Aluminium TPN electrolytic grade Busbar 1600Amp self standing indoor cubical main control confirming to IS 8623/1977-82 PE PWD specification for cubical panel fabricator out of 2mm thick CRCA sheet having with base frame made M.S sheet duly with one coat of primer red oxide staving spray painted with one coat of anit corrosion and finally painted synthetic enemal paint of front door powder coated. The panel should be complete in all respect as desired by the Engineer in charge of the work. (The panel should be fabricated by the CPRI tested manufactures ) Make : Vrindavan Electricals, Unitech Power Systems, Tricolite, AmbitIncomers-1ACB 4 pole 1600 Aamp., 50 KA EDO with MP-LSIG Release, 415 volts complete as per above Specs.-02 SetsUVT,Shunt Release 220V ACAux. BlockTNC SwitchMechanical and Electrical InterlockingAux. ContactorMultifunction Meter with RS485 Port or Equivalent (Class 1.0, with RS485 Port, with Paramenters V, Amp, PF, % THD, F,W,WH,VA,VAH, VAR,VARH, Runhrs, ON hrs, Interupts, Make : Schneider / Conzerv / Secure / SiemensMCB 6Amp / SP for Control. Make : Siemens / Legrand / SchneiderIndication Lamp LED Type for R, ,Y, B . Make : Siemens / Schneider / EsbeeLED Lamp 220V for ON / Off / TripCT`s -Resin Cast CT 1600/5 , Make : Kappa, A.E , Meco, NewTekCooling Fan and Terminal etcIncomers-2ACB 4 pole 1600 Aamp., 50 KA EDO with MP-LSIG Release, 415 volts complete as per above Specs.-02 SetsUVT,Shunt Release 220V ACAux. BlockTNC SwitchMechanical and Electrical InterlockingAux. ContactorMultifunction Meter with RS485 Port or Equivalent (Class 1.0, with RS485 Port, with Paramenters V, Amp, PF, % THD, F,W,WH,VA,VAH, VAR,VARH, Runhrs, ON hrs, Interupts, Make : Schneider / Conzerv / Secure / SiemensMCB 6Amp / SP for Control. Make : Siemens / Legrand / SchneiderIndication Lamp LED Type for R, ,Y, B . Make : Siemens / Schneider / EsbeeLED Lamp 220V for ON / Off / TripCT`s -Resin Cast CT 1600/5 , Make : Kappa, A.E , Meco, NewTekTerminal etcBus CouplerACB 4 pole 1600 Aamp., 50 KA EDO with MP-LSIG Release, 415 volts complete as per above Specs.-02 SetsUVT,Shunt Release 220V ACAux. BlockMechanical and Electrical InterlockingControl MCB 6A SP.10KA `C` Curve.LED Lamp 220V for ON / Off / TripTerminal etcOutgoing Feeders on Section- I630A 4Pole MCCB FEEDER :- 630A 4Pole 36KA MCCB with Thermal Magnetic Release with O/L, S/C, protections, Spreader Links, ROM and Aux. Contact BlockDigital Multifunction MeterLED Lamp 220V for ON / Off/ TripAlarm switch for MCCBControl MCB 6A SP.10KA `C` Curve.CTs 630/5A For MeteringCT Shorting Link and Terminal etc.250A 4Pole MCCB FEEDER :- 10 Set250A 4Pole 36KA MCCB with Thermal Magnetic Release with O/L, S/C, protections, Spreader Links, ROM and Aux. Contact BlockDigital Multifunction MeterLED Lamp 220V for ON / Off/ TripAlarm switch for MCCBControl MCB 6A SP.10KA `C` Curve.CTs 250/5A For MeteringCT Shorting Link and Terminal etc.Outgoing Feeders on Section- II630A 4Pole MCCB FEEDER :- 630A 4Pole 36KA MCCB with Thermal Magnetic Release with O/L, S/C, protections, Spreader Links, ROM and Aux. Contact BlockDigital Multifunction MeterLED Lamp 220V for ON / Off/ TripAlarm switch for MCCBControl MCB 6A SP.10KA `C` Curve.CTs 630/5A For MeteringCT Shorting Link and Terminal etc.250A 4Pole MCCB FEEDER :- 10 set250A 4Pole 36KA MCCB with Thermal Magnetic Release with O/L, S/C, protections, Spreader Links, ROM and Aux. Contact BlockDigital Multifunction MeterLED Lamp 220V for ON / Off/ TripAlarm switch for MCCBControl MCB 6A SP.10KA `C` Curve.CTs 250/5A For MeteringCT Shorting Link and Terminal etc.OTHER :- FabricationBus Bar Aluminium , Hardware and WiringOverhead/Profit etc |
| 21 | Buy back of old Main LT Panel , old VCB panel, all damaged panels, cables and appliances including lights and all electrical items, etc.. |
| 22 | SITC of prestressed cement concrete (PCC) pole as per IS : 1678-1960, Height 11 meters long 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 kg. burred 2.20 m in ground Complete the all necessary connection in all respect. ( Rate taken from UHBVN 2024) |
| 23 | HT PANEL- VCB( 1Incoming and 4 outgoing) Supply, erection, testing and commissioning of 1 plus 4 Panel, 1250 800A ,11 kV, 3 Phase, 50 Hz., metal clad, 500 MVA (26.3 KA) rupturing capacity Vacuum Circuit Breaker 1No. Incoming and 4 Nos. Outgoings as per the detailed specifications and drawings including connections etc. (ABB/Crompton/Siemens) Including interlocking as per technical spcifications and as required. INCOMER: 1 No. VCB Panel having following 1250A- VCB-Indoor Type (MDO) Horizontal Drawout Type, Mototrised Spring Charge Manually Operated Vacuum circuit Breaker as per IEC 62271 100/200/IS 13118 .11 KV ,Isc-18.4 KA for 3 Sec ,Break trip free breaker with SPMX mechanism, complete with self contained operated fully interlocked `Current Transformer: Indoor Single Phase Cast Resin Ratio 200/5-5A(As per requirement), Core-1 : 15 VA ,5P10 18.4KA- For IDMT Core-2 : 15 VA, CL-1 For Metering` `Potential Transformer:Indoor Single Phase Cast Resin Ratio: 11000/v3/110/v3/110/v3 V, Core-1: 100VA, Class: 0.5, Core-2, 100VA, Class : 3P ` Control MCBs 2A SP Control MCBs 6A DP 1 Set of Phase indicating lamps 1 No. Digital Voltmeter. 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY. Push button for ON, OFF and TRIP circuit healthy. 1 No. Digital Ammeter with selector switch and one set of C.T 100/5-5 A,Accuracy Class-0.5 For Measurement and Class 5P10 for Protection. Digital Multi Funtion Meter with RS 485.( Accuracy Class -0.5) I Set of undervoltage relay and Overvoltage relay. Trip circuit supervision relay, Auxiliary relays with shunt trip coil (WTI and Door open trip). Master Trip relay 1EF (50, 51, 50N, 51N) Numerical Type Protection Relay with TCS Power Pack 220V AC 6 Window Annunciator BUSBARS: Main Phase Bus Bar -2X80X10 mm Al, Earth Bus Bar 40 X 6 CU OUTGOINGS: 4 No. VCB each having the following: 800A- VCB-Indoor Type(MDO) Horizontal Drawout Type, Mototrrised Spring Charge Manually Operated Vacuum circuit Breaker as per IEC 62271 100/200/IS 13118 .11 KV ,Isc-18.4 KA for 3 Sec ,Break trip free breaker with SPMX mechanism,mounted on a truck carriage ,complete with self contained operated fully interlocked `Current Transformer: Indoor Single Phase Cast Resin Ratio 100/5-5A,(As required) Core-1 : 15 VA ,5P10 18.4KA- For IDMT Core-2 : 15 VA, CL-1 For Metering 40/5A` Control MCBs 6A DP 1 Set of Phase indicating lamps with HRC fuses. 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY. Push button for ON, OFF,TRIPandTRIP circuit healthy. 1 No. Digital Ammeter with selector switch and one set of C.T 30/5-5 A,Accuracy Class-0.5 For Measurement and Class 5P10 for Protection. 1 Set of Microcontroller based numerical relay having 4 element relay (3O/C plus 1E/F). Relay should have display of phase current and trip history. Digital Multi Funtion Meter with RS 485.( Accuracy Class -0.2) Master Trip relay, Aux Rely etc 3OC plus 1EF (50, 51, 50N, 51N) Numerical Type Protection Relay with TCS 6 window annunciator. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender