Tender for Supply Installation Testing and Commissioning of 400 Kva Dg Set (Cpcb Iv) And Lt Panel With Allied Items At Dav Police Public School Ambala City
BOQ
| Sl. No. | Item Description |
| 1 | HSR Item 24.12.76-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES76. 150 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 834.00 Through Rate |
| 2 | HSR Item 24.5.2.6-MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia HSR Rate(Rs.) 297.00 Through Rate |
| 3 | HSR Item 24.1.4-EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.HSR Rate(Rs.) 8275.00 Through Rate |
| 4 | HSR Item 23.22.2.2-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FPHSR Rate(Rs.) 4032.00 Through Rate |
| 5 | HSR Item 24.7.6-RCC FOUNDATIONS FOR DG SET 6. 400 KVA DG Set HSR Rate(Rs.) 90011.00 Through Rate |
| 6 | HSR Item 24.5.2.5-MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia HSR Rate(Rs.) 241.00 Through Rate |
| 7 | HSR Item 24.5.2.7-MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia HSR Rate(Rs.) 343.00 Through Rate |
| 8 | HSR Item 24.1.8-EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.HSR Rate(Rs.) 96.00 Through Rate |
| 9 | HSR Item 24.1.7-EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.HSR Rate(Rs.) 360.00 Through Rate |
| 10 | HSR Item 24.1.9-EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. HSR Rate(Rs.) 730.00 Through Rate |
| 11 | HSR Item 24.1.10-EARTHING AND LIGHTENINGARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.HSR Rate(Rs.) 730.00 Through Rate |
| 12 | HSR Item 24.7.4-RCC FOUNDATIONS FOR DG SET 4. 125 KVA DG Set HSR Rate(Rs.) 27801.00 Through Rate |
| 13 | HSR Item 24.1.3-EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.HSR Rate(Rs.) 3368.00 Through Rate |
| 14 | HSR Item 23.22.1.11-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA HSR Rate(Rs.) 10809.00 Through Rate |
| 15 | HSR Item 24.2.7.5-LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core HSR Rate(Rs.) 133.00 Through Rate |
| 16 | HSR Item 23.7.6.2-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.HSR Rate(Rs.) 32.00 Through Rate |
| 17 | HSR Item 24.2.9.7-LT CABLE 9.7. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 185 sqmm Cable 300 sqmm cable 3 to 4 CoreHSR Rate(Rs.) 6739.00 Through Rate |
| 18 | HSR Item 24.2.7.7-LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core HSR Rate(Rs.) 227.00 Through Rate |
| 19 | HSR Item 23.9-Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.HSR Rate(Rs.) 109.00 Through Rate |
| 20 | HSR Item 24.12.94-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES94. 300 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 1618.00 Through Rate |
| 21 | Total HSR |
| 22 | Electrical NS Item |
| 23 | MAIN LT PANEL Supply and Erection Testing and commissioning of indoor type LT PANEL Confirming specification for cubical panel fabricator out of 16/14 Gauge sheet having with base frame made M.S sheet duly with one coat of primer red oxide staving spray painted with one coat of anit corrosion and finally painted synthetic enemal paint of front door powder coated. INCOMER 1000A, 4P, ACB,MDO,50KA = 1 nos, AMP-METER= 1 Set VOLT-METER= 1 Nos PHASE INDICATION R,Y, = 1 Set PHASE INDICATION B= 2 Nos PHASE INDICATION B = 1Nos CT 1000/5A= 3 Nos CT SHORTING LINK = 3 Nos MCB 6A, SP, `C` curve, 10KA =3 Nos Neutral Link = 1 Nos OUTGOING-1:400A, TP, 36KA MCCB Thermal- Magnetic Based Release (With Over- Load and Short Circuit protection) = 2 NosEXTENDED ROH = 2 Nos Spreader link for 400A,TP = 2 Nos OUTGOING-2:250A, TP, 36KA MCCB Thermal- Magnetic Based Release (With Over- Load and Short Circuit protection) = 3 Nos EXTENDED ROH = 3 Nos Spreader link for 250A,TP = 3 NosCopper Busbar appropriate as per Requirment, Power and control wiring Will Be Copper for Appropriate Size and Ratings, Uses of heat shrink sleeves ,Nuts and bolts, insulators, PVC sleeves, thimbles, ferrules, cable ties, terminal blocks etc, MS Panel Fabricated in 16/14 Gauge Sheet Duly Powder Coated Process. The panel should be complete in all respect with wiring and Assembling as desired by the Engineer in charge of the work. Make of Accessories SCHNEIDER, LandT, ABB (Make of Panel ISO Approved) |
| 24 | NS Item - Supply and erection of metal body exhaust fan, double ball bearing suitable for single phase A.C. 230 Volts, 50 HZ capacitor, 900 RPM (Heavy duty) High speed complete with mounting ring, blade including louver shutter complete with fixing and making necessary connections etc. (i) Size 375 mm sweep |
| 25 | NS Item -Supply and erection of FRLS, PVC insulated unsheathed single core and PVC round sheathed multicore flexible copper cable for working voltage upto and including 1100 volts to is : 694/2010 – ISI marked complete in all respect. 1) Installation (Conduit, Cable tray, Surface / concealed), Accessories (Lugs, Glands (for multicore), Ferrules ISI marked complete in all respect..size 1.5 sqmm |
| 26 | -Supplying, Installation, Testing and Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV plus or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system, including testing at factory and site with fuel, load for test and other necessary arrangements with rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Deg C, 50% RH and at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with serviceindicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV plus or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018. (B) Engine mountedInstrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubrication Oil trip indication(ix) Engine Running Hours indication (x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C,50% RH and at 1000 Meter MSL. The alternator shall be |
| 27 | (viii) Low lubrication Oil trip indication(ix) Engine Running Hours indication (x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C,50% RH and at 1000 Meter MSL. The alternator shall be |
| 28 | having Screen ProtectedDrip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamicallybalanced rotor, capable of taking 10% over loading for one hour after 12 hoursof continuous operation, self cooled,self-excited and self-regulated through AVRconforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditionsand with class- H insulation.(D) Base Frame and Foundation: Both the engine and alternator shall be mountedon suitable base frame made of MS channel with necessary reinforcementwhich shall be installed on suitable cement concrete foundation and vibrationisolation arrangement as per recommendations of manufacturer.(E) FUEL TANK: Daily service fuel tank of suitable liters capacity, fabricated outof 3 mm thick M.S. sheet complete with all standard accessories and fuel pipingbetween fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia.Complete with valves, level indications and accessories as required as perspecifications. |
| 29 | (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencerand catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors:voltage regulator and arrangement for initial excitation complete with suitablenumbers of batteries (180 AH capacity lead acid SMF type) as required as perspecifications. The battery shall be housed inside the acoustic enclosure of DGSet.(H) Acoustic and weather proof enclosure with arrangement for fresh air intakeor cooling of the engine and alternator, extraction, discharging hot air in to theatmosphere and the temperature rise inside the enclosure, noise level outsideenclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such |
| 30 | arrangements on acousticenclosure should be water proof and dust-proof conforming to IP-65 protection.The enclosure shall be as per CPCB IV plus or better norms etc. and.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failurecontrol panel including auto by-pass, suitable for KVA as below for silent typeDG set complete with relays, timers, set of CTs for metering and protection andenergy analyser to indicate currents, phase and line voltages, frequency, powerfactor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase and Total),KW and provision for overload, short circuit, restricted earth fault, under frequency, |
| 31 | power (aluminium) and control (copper ) cabling of suitable size upto 15 meterbetween AMF panel, LT Panel and DG Set including connection interconnectionetc. as required, all complete and inter locking and communication/ Ethernet/RS485/SNMP port open protocol for BMS integration including suitablesoftware etc. as per approved by Engineering in charge and including thefollowing: 1. Suitable numbers and appropriate capacity 4 pole motorisedelectrically operated draw out with cradle type 3 position ACB/ MCCB withelectronic release for O/C and E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltagerelay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VAclass-I for metering5. Energy analyser unit to indicate current, Voltage( LN and L_L), kW, kVA (Phaseand Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,D.C. voltmeter and ammeter, selector switch for trickle, off and boost andcurrent adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to |
| 32 | 11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure tostart lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for (i) High water temperature(ii) Low lubricatingoil pressure (iii) Engine over speed (iv) Engine fails to start (v)Fullload/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour and due date.18. Load Management through PLC to achieve auto opening and closing ofincomer breakers, bus coupler switching of essential panel, interlockingproviding signal to AMF Panel for load status and AMF shall give command toDG Set to auto start / auto stop depending upon load status and requirementetc. and necessary hardware and software required to perform the operationshall be provided by the contractor including all control wiring.19. Suitable rating of AC contactors/ ATS / ACB with control wiring. Complete in all Respect.( NS Based on HSR 2026 item Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender