Tender For Special Repair Of Dav Police Public School In Police Lines, Sonipat.
Tender Value
71.53 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
12 days left
EMD
72000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonipat → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair Of Dav Police Public School In Police Lines, Sonipat.
BOQ
| Sl. No. | Item Description |
| 1 | [10.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. [Through Rate] |
| 2 | [10.30.1]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 1. Light shade pigment using white cement [Through Rate] |
| 3 | [10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick [Through Rate] |
| 4 | [10.45]Extra for pre finished nosing to treads of steps of marble stone. [Through Rate] |
| 5 | [10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 6 | [10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 7 | [10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate] |
| 8 | [10.70.2]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm [Through Rate] |
| 9 | [10.8]Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4 [Through Rate] |
| 10 | [11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 11 | [11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate] |
| 12 | [11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate] |
| 13 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 14 | [12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm [Through Rate] |
| 15 | [12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) [Through Rate] |
| 16 | [12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate] |
| 17 | [12.9.8]Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 8. Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading [Through Rate] |
| 18 | [12.98.2]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm [Through Rate] |
| 19 | [12.99.3]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm [Through Rate] |
| 20 | [12.99.5]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm [Through Rate] |
| 21 | [20.16]Fixing cost iron sluice valve surface boxes/indicating plates including cartage from Divisional Stores or nearest Railway Station and embedding to correct levels in cement mortar 1:3 [Through Rate] |
| 22 | [20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate] |
| 23 | [21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate] |
| 24 | [22.1.6]Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 6. White vitreous chinaware Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap [Through Rate] |
| 25 | [22.103.1]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore [Through Rate] |
| 26 | [22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate] |
| 27 | [22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore [Through Rate] |
| 28 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 29 | [22.174.1]Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 30 | [22.182]Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet and over flow pipes. The base support i/c fittings and fixtures for tank shall be paid separately. [Through Rate] |
| 31 | [22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate] |
| 32 | [22.22.1]Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests [Through Rate] |
| 33 | [22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate] |
| 34 | [22.47]Providing and fixing white vitreous chinaware flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. [Through Rate] |
| 35 | [22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 36 | [22.86.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 37 | [23.12]Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required [Through Rate] |
| 38 | [23.17.2]Replacement of a fan condenser complete with connections and testing etc. 2. 4 to 6 mfd [Through Rate] |
| 39 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate] |
| 40 | [23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate] |
| 41 | [23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA [Through Rate] |
| 42 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate] |
| 43 | [23.22.2.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.3. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB above 250 A and up to 630 A FP [Through Rate] |
| 44 | [23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 45 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 46 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] |
| 47 | [23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE [Through Rate] |
| 48 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 49 | [23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts [Through Rate] |
| 50 | [23.23.5.1]MISCELLANEOUS 5.1. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 25x12 mm [Through Rate] |
| 51 | [23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate] |
| 52 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 53 | [23.28.1.4]Supplying, installation, Testing and Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5%), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 4. Powder coated die cast /Extruded aluminum Body including trim 18 watt [Rate] |
| 54 | [23.28.15.3]Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80 , under voltage and over voltage protection, EMI- EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 3. 100 watt [Rate] |
| 55 | [23.28.6.10]Supplying, installation, Testing and Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 degree centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection, THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 10. CRCA Sheet Body (Thickness >= 0.50 mm) 36 watt [Rate] |
| 56 | [23.28.6.4]Supplying, installation, Testing and Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 degree centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection, THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. Powder coated die cast / Extruded aluminium Body (Thickness >= 1.20 mm) 36 watt [Rate] |
| 57 | [23.28.9.3]Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 3. Powder coated die cast / Extruded aluminium Body (Thickness >= 1.20 mm) 36 Watt [Rate] |
| 58 | [23.29.2.3]Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 3. 1200mm, service value >= 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) [Rate] |
| 59 | [23.29.2.4]Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 4. 1400mm, service value >= 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) [Rate] |
| 60 | [23.33.1 (a).1]Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)`s both for the rectifier and inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be )95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be ( 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz plus /- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 and 3). The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 1. 2KVA [Rate] |
| 61 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 62 | [23.5.6.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] |
| 63 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 64 | [23.5.6.4]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate] |
| 65 | [23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate] |
| 66 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 67 | [23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. [Through Rate] |
| 68 | [23.8.1.13]FITTING AND ACCESSORIES 1.13. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Socket size rotary step type Electronic regulator for A.C. ceiling fan [Through Rate] |
| 69 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] |
| 70 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] |
| 71 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate] |
| 72 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 73 | [23.8.2.1]FITTING AND ACCESSORIES 2.1. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 5 mm thick [Through Rate] |
| 74 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 75 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 76 | [24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate] |
| 77 | [24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. [Through Rate] |
| 78 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 79 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] |
| 80 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 81 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 82 | [24.10.4]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 4. cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including from work, placing and fixing in position, complete at the ground level or in first storey [Through Rate] |
| 83 | [24.10.6]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 6. Digging of pucca road in required width for laying of cable / pipe complete in all respect up to the entire satisfaction of Engineer-in charge [Through Rate] |
| 84 | [24.14.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate] |
| 85 | [24.14.64]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 64. 95 Sq mm 4 core (Arm.) [Through Rate] |
| 86 | [24.5.1.3]MISCELLANEOUS ITEMS 1.3. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 4 sqmm [Through Rate] |
| 87 | [24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate] |
| 88 | [30.17]Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. [Through Rate] |
| 89 | [30.22]Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. [Through Rate] |
| 90 | [30.93]Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube Challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. [Through Rate] |
| 91 | [5.23.1]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) [Through Rate] |
| 92 | [5.45]Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. [Through Rate] |
| 93 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 94 | [6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 95 | [9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate] |
| 96 | [9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate] |
| 97 | Servicing and Testing of 62.5 KVA D.G Set with Cleaning and lubrication of all moving parts including Premium Oil , Filter Oil, Inhibitor Corrosion, Seperator Fuel Water, Element Air Filter primary and secondary, and complete with handling and services charges and all other petty material to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work. |
| 98 | Supply and Erection of R.O Membrane Aquaguard (bacteria, Virus, cysts, TDS removal) for water purifier. (NS). |
| 99 | Supply, carriage, erection, testing and commissioning of 380mm sweep A.C. Exhaust fan Heavy duty 900 rpm suitable for single phase A.C. 230 Volts, 50 HZ capacitor, 900 RPM (Heavy Duty) complete with mounting ring frame with four fixing holes and automatic louver shutter but without regulator. The exhaust fan is to be fixed in the existing glazing with suitable MS frame of required thickness as per site including its painting etc. as per site requirement. |
| 100 | Supply, Installation, Testing and Commissioning of Switch should be Web Managed, Should have 8 port 1000BASE-T with 4 Port 1000BASE-T PoE PoE power budget 160 Watt or higher, Maximum Per port PoE Power 30 Watt IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Ethernet, IEEE 802.3ab 1000BASE-T Ethernet, IEEE 802.3az EEE support, IEEE 802.3x flow control, IEEE 802.3z 1000BASE-X,IEEE 802.1p CoS, IEEE 802.3af PoE, IEEE 802.3at PoE Plus, IEEE802.1Q VLAN Tagging, Minimum 8 VLAN support Port based VLAN, IEEE802.3ad link aggregation should be MAC based Switching Capacity 16 Gbps, Packet buffer 192KB,MAC address support 4K Jumbo frame support 9K, Should support loop detection, Should support Broadcast storm control QoS Support (WRR and strict priority) Port based QoS 20 Multicast group or higher, Maximum power consumption 72W,Operating temperature 0°C to 40°C Storage Temperature - 40°C to 70°C Certification: CE, FCC, C-Tick, , LVD EN60950-1, ROHS compliant Should be built-in IEEE 802.3az Energy Efficient Ethernet (EEE). |
| 101 | Supply, Installation, Testing and Commissioning of 8 Port PoE Switch 8 10/100/1000 Mbps gigabit ethernet ports, 2 10/100/1000 Mbps uplink port, 120watts available PoE, Flow control for protection against data loss, Maximum distance of 250m, Light protection 6KV, Operating Temperature: 0 to 40 deg C (32 to 104 deg F). complete in all respect upto the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc. |
| 102 | Supply, Installation, Testing and Commissioning of Commercial grade 55 inch DISPLAY UNIT having followingtechnical specification 1. Display Size: 55 inches or more2.Resolution and built in:3840 x 2160 (UHD) ,4K 3. AUDIO:Advanced Audio 4. Built in: Bluetooth Connectivity (optional),built in Wi Fi, 5. Built in Speaker:20W 6. Others: HDMI X 3, DPX 1, USB X1, RJ45 X 1, Digital audio out. 7.Brightness:300cd/m2 or better 8. Dashboard feature: SNMP support to takecontrol of display to check, Diagnose and Corrections throughLAN network, Wake on LAN 9. Operation Temperature:0 °C to40 °C or better, humidity 80% 10. Warranty: 3 years onsite11.Mounting: Wall mount and table mount both 12. DisplayType:24x7 working compatibility 13. Certificates andApprovals: BIS, ISO 9001, CB/UL.MAKE -_ - SAMSUNG, LG, PANASONIC |
| 103 | Supply and Erection of 10m HDMI 2.0 Cable. High-Speed HDMI with Ethernet (Category 2). 10.0 Meters (32.8 feet). Full 18Gbps (supports HDMI 2.0b standards). 4K @ 60Hz (4:4:4) Ultra HD. ARC (Audio Return Channel), Dolby Atoms and up to 32 audio channels. 19-pin HDMI Type-A Male to Male. Gold-plated connectors to resist corrosion and ensure low contact resistance. Zinc Alloy or heavy-duty PVC Molded shell with strain relief. Minimum 24 AWG or 26 AWG Oxygen-Free Copper (OFC) to minimize signal attenuation over the 10m distance. Triple-layer shielding EMI/RFI protection. UL-listed, fire-retardant PVC or CL3-rated (safe for in-wall installation). HDCP Compliance HDCP 2.2 / 1.4, Color Depth 48-bit Deep Color, Outer Diameter Approx. 8.5 mm to 10.0 mm., Compliance RoHS, CE, FCC.complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. |
| 104 | Supply and Erection of 3 ft (1m) UTP Cat6/6a Patch Cord Unshielded Twisted Pair (UTP) High-Speed Patch Cable. 3 Feet Standard for rack-to-switch cross-connects. Available in Cat6 (250MHz) or Cat6a (500MHz) variants. Conductors 24 AWG or 26 AWG Stranded Pure Copper for maximum flexibility (resists breaking from frequent bending). Connectors Type: RJ45 Male to RJ45 Male. Contacts 50-micron Gold Plated to prevent oxidation and maintain high signal conductivity. Jacket Material Standard PVC. High Safety: LSZH (Low Smoke Zero Halogen) for environments with strict fire codes. Data Rate Up to 1Gbps (Cat6) / 10Gbps (Cat6a), Outer Diameter Approx. 5.5mm - 6.2mm, Mating Cycles Tested for ) 750 insertions, Compliance TIA/EIA 568.2-D, RoHS, UL Listed etc. complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. |
| 105 | Supply and Erection of Cable Assembly for conference system 10 or more Mtr, Difference types of Cable use in conference system Likes Active HDMI (AOC) Direct connection from laptop to a far projector, HDBaseT (Cat6) Complex setups with Power-over-Ethernet (PoE) and control., SDI (Coax) Broadcast-quality video or permanent wall-mounted cameras., XLR Long-distance microphone runs to a mixer. complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: - Bosch/ Televic/ Brahler. |
| 106 | Supply, installation, testing and commissioning of 5MP Bullet Camera with Lens 3.6 mm Fixed lens, IR Range 30 Mtr. , SD Slot and audio supported , IP67, IK10 with following specifications: - Image Sensor: -1/1.8”, 5MP Low Illumination Progressive Scan CMOS Sensor Lens: - 3.6mm fixed lens, 5MP (2560(H)x1920(V)) at 25/30 fps with 30 Meter of inbuilt IR, IP 67 and IK 10 rated Resolution: - 5MP 2560(H)x1920(V) at 25/30 fps Min Illumination: - 0.001Lux @ (F1.2, AGC ON), 0.014 Lux @ (F1.4, AGC ON), 0 Lux with IR Day/Night: - Auto (ICR) / Color / BW WDR: - 120 dB S/N Ratio = 50 dB Video Compression: - H.265/H.264/MJPEG Motion Detection: - Yes Alarm Trigger: - Motion Detection, Network Disconnection, Smart Event - Motion Detection - Set Detection Area, Period, Can Set Multi-Level Sensitivity, Tamper Detection - Alerts when the camera is blocked, defocused, or tampered intentionally or unintentionally ,External Input, Audio Alarm, IP Address conflict, illegal Access, Storage anomaly: Iris Control: - Auto Frame Rate: - 1fps - 25/30fps Network Protocol: - ONVIF Profile - S,G,T : Individually configured minimum 04 video streams 2 Way Audio: - Yes Motion Detection: - Yes SD Card: - Minimum 256 GB on-board Class 10 speed SD Card having Linux Unified card encryption key Video In/Out / Other Features: - WDR, BLC, HLC: 120dB WDR: White Balance - Auto / Tungsten / Daylight / Manual: Gain Control 0~100%: 2D/3D DNR: EIS: DEFOG: Minimum 5 Areas of Privacy Masking: Smart IR Light Controller (Auto/Manual)/OFF : TDN - Auto (ICR) / Color / BW Audio In/Out: - 1 in/ 1 out Alarm In/Out: - 1 in/1out Ethernet: - RJ-45 10/100 Base T Security: - Authorized username and password, HTTPS with password, HTTPS digest authentication Watermark, RTSPS, AES 256 encryption, Signed Firmware, TEE (Trusted Execution Environment), User Authentication and encrypted firmware, Hardware Secure Boot Protocol: - TCP/IP, IPv4, IPv6, SSL, TLS, UDP, HTTP/HTTPS, HTTP-Base64, HTTP-Digest, DHCP, DNS, RTP,RTSP , NTP, SMTP, IGMP, Multicast Operating Temperature: - Temperature: -40 °C ~ 70 °C/ Humidity: 0-90% RH , Ingress Protection: - Weather Proof IP67: IK10 IR Range: -30 m with inbuilt IR Light Controller for Auto / Manual / OFF including a minimum of 04 nos of IR Lights : ONVIF - G, S, T, Certifications - CE, FCC, BIS, STQC i.e as Meity Guidelines : ER : Essential Requirement(s) for Security of CCTV have been published in Ministry of Electronics and information Technology (MeitY) Public Procurement (Preference to Make in India) Order 2017-Notifying CCTV/ Video Surveillance System for Security in furtherance of the Order dated 6th March,2024 along with Trusted Supply Chain. The testing agency authorized to do the Essential Requirement testing is STQC or any other agency notified by MeitY from time to time. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. |
| 107 | Supply, installation, testing and commissioning of 5MP Dome Camera with Lens 3.6 mm Fixed lens, IR Range 30 Mtr. , SD Slot and audio supported , IP67, IK10 with following specifications: - Image Sensor: -1/1.8”, 5MP Low Illumination Progressive Scan CMOS Sensor Lens: - 3.6mm fixed lens, 5MP (2560(H)x1920(V)) at 25/30 fps with 30 Meter of inbuilt IR, IP 67 and IK 10 rated Resolution: - 5MP 2560(H)x1920(V) at 25/30 fps Min Illumination: - 0.001Lux @ (F1.2, AGC ON), 0.014 Lux @ (F1.4, AGC ON), 0 Lux with IR Day/Night: - Auto (ICR) / Color / BW WDR: - 120 dB S/N Ratio = 50 dB Video Compression: - H.265/H.264/MJPEG Motion Detection: - Yes Alarm Trigger: - Motion Detection, Network Disconnection, Smart Event - Motion Detection - Set Detection Area, Period, Can Set Multi-Level Sensitivity, Tamper Detection - Alerts when the camera is blocked, defocused, or tampered intentionally or unintentionally, External Input, Audio Alarm, IP Address conflict, illegal Access, Storage anomaly: Iris Control: - Auto Frame Rate: - 1fps - 25/30fps Network Protocol: - ONVIF Profile - S,G,T : Individually configured minimum 04 video streams 2 Way Audio: - Yes Motion Detection: - Yes SD Card: - Minimum 256 GB on-board Class 10 speed SD Card having Linux Unified card encryption key Video In/Out / Other Features: - WDR, BLC, HLC: 120dB WDR: White Balance - Auto / Tungsten / Daylight / Manual: Gain Control 0~100%: 2D/3D DNR: EIS: DEFOG: Minimum 5 Areas of Privacy Masking: Smart IR Light Controller (Auto/Manual)/OFF : TDN - Auto (ICR) / Color / BW Audio In/Out: - 1 in/ 1 out Alarm In/Out: - 1 in/1out Ethernet: - RJ-45 10/100 Base T Security: - Authorized username and password, HTTPS with password, HTTPS digest authentication Watermark, RTSPS, AES 256 encryption, Signed Firmware, TEE (Trusted Execution Environment), User Authentication and encrypted firmware, Hardware Secure Boot Protocol: - TCP/IP, IPv4, IPv6, SSL, TLS, UDP, HTTP/HTTPS, HTTP-Base64, HTTP-Digest, DHCP, DNS, RTP,RTSP , NTP, SMTP, IGMP, Multicast Operating Temperature: - Temperature: -40 °C ~ 70 °C/ Humidity: 0-90% RH , Ingress Protection: - Weather Proof IP67: IK10 IR Range: -30 m with inbuilt IR Light Controller for Auto / Manual / OFF including a minimum of 04 nos of IR Lights : ONVIF - G, S, T : Certifications - CE, FCC, BIS, STQC i.e as Meity Guidelines : ER : Essential Requirement(s) for Security of CCTV have been published in Ministry of Electronics and information Technology (MeitY) Public Procurement (Preference to Make in India) Order 2017-Notifying CCTV/ Video Surveillance System for Security in furtherance of the Order dated 6th March,2024 along with Trusted Supply Chain. The testing agency authorized to do the Essential Requirement testing is STQC or any other agency notified by MeitY from time to time. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. |
| 108 | Supply, installation, testing and commissioning of 5MP Bullet Camera with Lens 5~50 mm, IR Range 100 Mtr. , SD Slot and audio supported , IP67, IK10 with following specifications: - Image Sensor: -1/1.8”, 5MP Low Illumination Progressive Scan CMOS Sensor Lens: - 5~50mm 5MP (2560(H)x1920(V)) at 25/30 fps with 100 Meter of inbuilt IR External IR illuminator: - IP 67 and IK 10 rated Resolution: - 5MP 2560(H)x1920(V) at 25/30 fps Min Illumination: - 0.001Lux @ (F1.2, AGC ON), 0.014 Lux @ (F1.4, AGC ON), 0 Lux with IR Day/Night: - Auto (ICR) / Color / BW WDR: - 120 dB S/N Ratio = 50 dB Video Compression: - H.265/H.264/MJPEG Motion Detection: - Yes Alarm Trigger: - Motion Detection, Network Disconnection, Smart Event - Motion Detection - Set Detection Area, Period, Can Set Multi-Level Sensitivity, Tamper Detection - Alerts when the camera is blocked, defocused, or tampered intentionally or unintentionally, External Input, Audio Alarm, IP Address conflict, illegal Access, Storage anomaly: Iris Control: - Auto Frame Rate: - 1fps - 25/30fps Network Protocol: - ONVIF Profile - S,G,T : Individually configured minimum 04 video streams 2 Way Audio: - Yes Motion Detection: - Yes SD Card: - Minimum 256 GB on-board Class 10 speed SD Card having Linux Unified card encryption key Video In/Out / Other Features: - WDR, BLC, HLC: 120dB WDR: White Balance - Auto / Tungsten / Daylight / Manual: Gain Control 0~100%: 2D/3D DNR: EIS: DEFOG: Minimum 5 Areas of Privacy Masking: Smart IR Light Controller (Auto/Manual)/OFF : TDN - Auto (ICR) / Color / BW Audio In/Out: - 1 in/ 1 out Alarm In/Out: - 1 in/1out Ethernet: - RJ-45 10/100 Base T Security: - Authorized username and password, HTTPS with password, HTTPS digest authentication Watermark, RTSPS, AES 256 encryption, Signed Firmware, TEE (Trusted Execution Environment), User Authentication and encrypted firmware, Hardware Secure Boot Protocol: - TCP/IP, IPv4, IPv6, SSL, TLS, UDP, HTTP/HTTPS, HTTP-Base64, HTTP-Digest, DHCP, DNS, RTP,RTSP , NTP, SMTP, IGMP, Multicast Operating Temperature: - Temperature: -40 °C ~ 70 °C/ Humidity: 0-90% RH , Ingress Protection: - Weather Proof IP67: IK10 IR Range: - 100 m with inbuilt IR Light Controller for Auto / Manual / OFF including a minimum of 04 nos of IR Lights : ONVIF - G, S, T : Certifications - CE, FCC, BIS, STQC i.e as Meity Guidelines : ER : Essential Requirement(s) for Security of CCTV have been published in Ministry of Electronics and information Technology (MeitY) Public Procurement (Preference to Make in India) Order 2017-Notifying CCTV/ Video Surveillance System for Security in furtherance of the Order dated 6th March,2024 along with Trusted Supply Chain. The testing agency authorized to do the Essential Requirement testing is STQC or any other agency notified by MeitY from time to time. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. |
| 109 | Supply, installation, testing and commissioning of NVR- 16 Channel, with Incoming and outgoing bandwidth of 270 Mbps, minimum 2 SATA port , support of minimum 32 TB storage (2 no`s HDD X 16 TB each) with minimum features: supporting channel :36 channels, Bandwidth :150 Mbps (Incoming)/120 Mbps (Outgoing) Recording Resolution: Upto 12 MP Video Output: 1 HDMI, 1 VGA Ports, USB interface:3xUSB 2.0, Minimum Support up to 16TB at Each SATA Port, Alerts: Generate alerts for camera or equipment malfunction and replacement, HDD failures, HDD tampering, etc. Auto start/ Resume :should be capable of auto start/Resume operations post power fluctuation/ failure Access Management: Feature to limit access to storage data with access management Connectivity Interface:1 Nos. x 10/100/1000 Base-T Lan Port Backup, Operating Condition:0°C to 55°C, humidity 80% (max), System Capability: Should be ONVIF Profile G, S and T Note: Quoted Model should be listed on ONVIF website and NVR OEM should not be blacklisted by ONVIF. Certifications: BIS Certified, UL/CE/FCC Additional feature - Auto resume, VMS: Must have pre-loaded VMS, ONVIF complaint. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. |
| 110 | Supply and Erection of 6U Wall-Mount Rack (Loaded) 6U height, standard 19-inch rack, Width 550 mm to 600 mm, Height 350 mm, Depth 450 mm, Heavy-duty, fully welded CRCA (Cold Rolled Close Annealed) steel sheets (minimum 1.0mm to 1.2mm thickness). Supports a static weight load of up to 40–50 kg. Pre-treated, anti-corrosive powder-coated finish (typically Light Grey, RAL 7035, or Black). complete in all respect up to the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc. |
| 111 | Supply and Erection of 2300 VA pure sine wave Inverter with 2 years warranty, backup time up to 8 hours suitable for operation on single phase 230 volts, 50 HZ, AC supply, with 2 no`s of Lead acid batteries of 150 AH 12 volt per battery having warranty of 2 years complete with trolley Battery Trolley Specifications: Sturdy plastic trolley compatible with Tall Tubular Batteries Designed for 2 batteries. I/c making necessary connections. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender