Tender for Permanent Cathodic Protection Works For Up Gradation Steel Pipeline Network At Aligarh U.P.
BOQ
| Sl. No. | Item Description |
| 1 | PCP-DESIGN & ENGINEERING PACKAGE |
| 2 | Preparation and submission of Design Basis, Carrying out pre design survey, Detailed Engineering design of PCP system, Preparation BOM/BOQ, Data Sheets, Drawings, list of crossings, ITP and other Formats,etc. for PCP for Permanent Cathodic Protection system including corrosion survey as per approved procedure and scope of work in this tender |
| 3 | PCP-SUPPLY |
| 4 | Supply of various items as listed below for PCP jobs as per technical scopes and specifications mentioned in tender documents. |
| 5 | Supply of AC Operated CPTR Unit - Automatic Controlled, RMU and GPS based current interrupter timer facility, 35V/25A or 48V/25A, Automatic, Air cooled, Indoor type with remote montioring and control through SCADA facility as per IOAGPL specification/tender document. |
| 6 | Supply of 1\\" dia & 1 M long 8A rating LIDA MMO anode sets for Deepwell anode ground bed (Each set consist of 10 Nos. of anode) with petroleum cock breeze, anode cable & cable joints etc. |
| 7 | Junction Boxes |
| 8 | Supply of Anode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof) |
| 9 | Supply of Cathode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof) |
| 10 | Permanent Reference Cell |
| 11 | Cu/CuSO4 Permanent Reference cell |
| 12 | Ag/AgCl Permanent Reference cell (Shall be used only if required based on survey report) |
| 13 | Supply of PCP Cables- The Cables shall be annealed high conductivity, stranded copper conductor, 650/1100V grade, XLPE Insulated & PVC Sheathed |
| 14 | 1c x 6 mm2 - armoured for potential measurement, Ref Cell etc. |
| 15 | 1Cx 25 mm2- armoured for Bonding/Grounding etc. |
| 16 | 1Cx 35 mm2- armoured for Anode & Cathode Header Cable etc. |
| 17 | 3C X 10mm2- armoured for TR/CPPSM unit incomer cable etc. |
| 18 | 1C X 10mm2- armoured cable |
| 19 | Supply of ER probes at site |
| 20 | Supply of ER probe Readers |
| 21 | Supply of Polarisation coupons (100 mmx100mm) with Magnetic reed switch, Pipe piece will be provided by IOAGPL |
| 22 | Supply of Solid State type Polorisation cells for HT power line crossings (66KV & above) |
| 23 | Supply of Surge Diverter for IJ |
| 24 | 20 Kg Sacrifical Zinc anodes for HT line crossing, Earthing of block valves on Cathodically Protected portion of pipeline |
| 25 | Earthing Electrodes 65mm dia x 3mtr long & 4.5 mm thick GI pipe for earthing of cathodically inprotected pipeline |
| 26 | Test Stations (Weather Proof with IP-55) |
| 27 | Normal Size as per tender drawings - Supply of Test Station (TLP) Box Type A/B/C/D/E/I etc. weatherproof as per IOAGPL approved data sheet/drawing |
| 28 | Big Size suitable for Polarisation Cells - Supply of Big Size (HT Line/ Bonding)Test Station weatherproof as per IOAGPL approved data sheet and drawings |
| 29 | Supply of Thermit welding/CAD kit for Cable to pipe connections by Thermit welding method for all sizes all cable sizes including encapsulation |
| 30 | Supply of Cable to pipe connections by Pin brazing method for all sizes all cable sizes including encapsulation |
| 31 | Supply of Recommanded Spares for 2 Years Operation & Maintenance of CP system as per spare list enclosed in Vol. II of II (TechnicalSpecification) |
| 32 | Supply of Cable Route Marker |
| 33 | PCP-SERVICE |
| 34 | Installation, Testing & Commissioning (ITC) of below items for PCP system |
| 35 | This includes, all civil works, structural works, electrical works, earthing, cable connections, sand paddings, brick works, repair works, painting works and all other allied works required for installation, testing and commissioning of PCP System. |
| 36 | Soil Resistivity Survey at PCP anode ground bed Locations along with soil chemical analysis (per location) |
| 37 | Erection, Installation, Testing & Commissioning of AC Operated CPTR Unit - Automatic Controlled, RMU and GPS based current interrupter timer facility, Min 35V/25A or 48V/25A Automatic, Air cooled, Indoor type with remote montioring and control through SCADA facility as per IOAGPL specification/tender document. inclduing construction of civil foundation, if required, for CPTR Unit. |
| 38 | Deepwell anode groundbeds consisiting of 1\\" Dia x 1M long 8Amp Rating Lida Single (MMO) Electrode sets including cutting trench & backfill with Petroleum Cokebreeze or Drilling of borehole, lowering of MS Casing pipe & PVC pipe with petroleum coke breeze backfill and anode tail cable laying etc as required to complete the installation of the AGB in all respect including all civil restoration |
| 39 | ITC of Junction Boxes |
| 40 | Anode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof) |
| 41 | Cathode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof) |
| 42 | ITC of Permanent Reference Cell |
| 43 | Cu/CuSO4 Permanent Reference cell |
| 44 | Ag/AgCl Permanent Reference cell (Shall be used only if required based on survey report) |
| 45 | ITC of of PCP Cables- The Cables shall be annealed high conductivity, stranded copper conductor, 650/1100V grade, XLPE Insulated & PVC Sheathed |
| 46 | 1c x 6 mm2 - armoured for potential measurement, Ref Cell etc. |
| 47 | 1Cx 25 mm2- armoured for Bonding/Grounding etc. |
| 48 | 1Cx 35 mm2- armoured for Anode & Cathode Header Cable etc. |
| 49 | 3C X 10mm2- armoured for TR/CPPSM unit incomer cable etc. |
| 50 | 1C X 10mm2- armoured cable |
| 51 | ITC of ER probes |
| 52 | ITC of Polarisation coupons (100 mmx100mm) with Magnetic reed switch, Pipe piece will be provided by IOAGPL |
| 53 | ITC of Solid State type Polorisation cells for HT power line crossings (66KV & above) |
| 54 | ITC of Surge Diverter for IJ |
| 55 | ITC 20 Kg Sacrifical Zinc anodes for HT line crossing, Earthing of block valves on Cathodically Protected portion of pipeline |
| 56 | ITC Earthing Electrodes 65mm dia x 3mtr long & 4.5 mm thick GI pipe for earthing of cathodically inprotected pipeline |
| 57 | ITC of Test Stations (Weather Proof with IP-55) |
| 58 | Providing shed of suitable size (minimum 3mX3m) with 75X75X5mm angles and FRP sheet for TR unit installaed outdoor including all civil works for foundation and grouting of poles |
| 59 | Cable to pipe connections by Pin brazing / Thermit welding method for all sizes all cable sizes including encapsulation |
| 60 | Intallation, Painting and lettering of Cable Route Marker |
| 61 | Repair of damaged 3LPE with approved compatible sleeve/epoxy including excavation & restoration (per location) |
| 62 | Cleaning, Painting, Numbering and Installation of circuit diagram plate for existing TLP boxes |
| 63 | Post Commissioning Surveys and submission of drawings/reports/dcouments |
| 64 | CIPL Survey |
| 65 | Current Attenuation Test Survey (CAT) |
| 66 | CAT with \\"A\\" Frame or DCVG Survey at Holiday / Defect Location |
| 67 | AC-DC Interference Detection and Mitigation of entire network |
| 68 | Monitoring and maintenance of PCP system once a Month till Handing Over for six months from date of Commissioning. |
| 69 | Flame proof Big Size suitable for Polarisation Cell & Insulation joint connection |
| 70 | Supply of Big Size (HT Line/ Bonding/IJ)Test Station flameproof as per IOAGPL approved data sheet and drawings |
| 71 | ITC of Big Size (HT Line/ Bonding/IJ)Test Station flameproof as per IOAGPL approved data sheet and drawings Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender