Power Government Departments Closing in 13 days TDR #57184591

Tender For Construction Of Four Storeyed B- Type Quarter Along With Sanitary, Plumbing And Internal Electrification, Development Of Quarter Premises, Development Of Bore Well By Reverse Rotary Method, Sinking Submersible Pump And Installation Of 2000

Issued by Government Departments · Darjeeling, West Bengal
Tender Value
2.19 Crore
Estimated cost
Bid Submission
24 Sep 2026
13 days left
EMD
4.39 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Four Storeyed B- Type Quarter Along With Sanitary, Plumbing And Internal Electrification, Development Of Quarter Premises, Development Of Bore Well By Reverse Rotary Method, Sinking Submersible Pump And Installation Of 2000 Lph Iron Elimination Pump For The Proposed B-Type Quarter At Powerhouse Complex, 2Nd Mile, Siliguri Under Hydel Headquarters.

BOQ

Name of Work:- Construction of four storeyed B- TYPE Quarter along with Sanitary, Plumbing and Internal Electrification, Development of Quarter premises, Development of Bore well by Reverse rotary method, Sinking submersible pump and installation of 2000 LPH Iron elimination pump for the proposed B-type Quarter at Powerhouse Complex, 2nd Mile, Siliguri under Hydel Headquarters.
Sl. No. Item Description
1A) CIVIL WORKS:-a) For the B-type Quarter & Surrounding Area DevelopmentEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
2(b) Depth of excavation for additional depth beyond 1500 mm and upto 3000 mm. But not requiring shoring.
3Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation.
4Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement beforeand after the work) With earth obtained by fresh excavation upto 1800 mm. depth (including the cost of excavation from land arranged by the Deptt. within a lead of 100 m.)
5Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
6Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed
7Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15cm depth and disposal of the rubbish within a lead upto 75 m as directed.
8Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specifications Clause 201 for Rural Roads of MORD. A. Lead upto 100 m v) Girth above 1800 mm to 2700 mm
9Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity).Do by Fine sand
10Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
11Cement concrete with 30mm down graded shingles excluding shuttering. N.B. Variety a) In ground floor (1:3:6) proportion.
12Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm.nominalsize) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.a) River bazree.
13In 1st floor.
14In 2nd floor.
15In 3rd floor.
16Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) With River Bazree. In ground floor and foundation.
17In 1st Floor.
18In 2nd Floor.
19In 3rd Floor.
20In 4th Floor.
21Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works.(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. In ground floor.
22In First Floor.
23In 2nd Floor.
24In 3rd Floor.
25In 4th Floor.
26(b) 25 mm to 30 mm shuttering without staging in foundation
27Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bennding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i) Tor steel/Mild steel(SAIL/TATA/RINL) In Ground Floor
28In First Floor.
29In 2nd Floor.
30In 3rd Floor.
31In 4th Floor.
32Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth
33Brick work with 1st class bricks in cement mortar (1:4) In Ground Floor.
34In 1st Floor.
35In 2nd Floor.
36In 3rd Floor.
37In 4th Floor.
38125 mm. thick brick work with 1st class bricks in cement mortar (1:4) In ground floor.
39In 1st floor.
40In 2nd Floor.
41In 3rd Floor.
4225mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).
43Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
44Using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.
45Labour for Chipping of concrete surface before taking up Plastering work.In ceiling, beam sides & soffit, column faces, staircase etc.
46Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.] (A) With 1:4 cement mortar (a) 15 mm. thick plaster. In ground floor.
47In 1st floor.
48In 2nd Floor.
49In 3rd Floor.
50In 4th Floor.
51Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.] (A) With 1:4 cement mortar (a) 20 mm. thick plaster. In ground floor.
52In 1st floor.
53In 2nd Floor.
54In 3rd Floor.
55In 4th Floor.
56Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.] (A) With 1:4 cement mortar (a) 10 mm. thick plaster. In ground floor.
57In 1st floor.
58In 2nd Floor.
59In 3rd Floor.
60In 4th Floor.
61Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu. M. per sq.m.
62Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing imidacloprid emulsifiable concentrates (105 ml to 50 ltres)) with water at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3 of code IS-6313(part-0II)2013 ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
63Pre Construction: Anti termite Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing imidacloprid emulsifiable concentrates (160 ml to 75 ltres) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in 7.3.1 of code IS-6313(Part-II) 2013 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
64Post Construction: Anti-termite treatment to the outside of foundations with chemical emulsion by admixing imidacloprid emulsifiable concentrates (62 ml in 28.5 litres) with including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 5.3.1.1 of codeIS-6313 (Part-III) 2013.
65Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) In ground floor.
66In first floor.
67In 2nd Floor.
68In 3rd Floor.
69In 4th Floor.
70Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat Water based interior grade Acrylic Primer
71Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C(i) One coat on new surface. In ground floor.
72In first floor.
73In 2nd Floor.
74In 3rd Floor.
75In 4th Floor.
76Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (i) Two coats ii) Luxury Quality
77Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Premium 100% Acrylic Emulsion. In ground floor.
78In first floor.
79In 2nd Floor.
80In 3rd Floor.
81In 4th Floor.
82Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.)
83Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.)
84Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (a) On timber or plastered surface :With super gloss (hi-gloss) -(i) Two coats (with any shade except white)
85(b) On steel or other metal surface : With super gloss (hi-gloss) - (i) Two coats (with any shade except white)
86Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 N
87In first floor.
88In 2nd Floor.
89In 3rd Floor.
90Supplying, fitting & fixing 1st quality Ceramic tiles in wall and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc (B) Wall With Polymerised Adhesive & Epoxy grout pointing With Polymerised Adhesive and Epoxy grout pointing including spacer-2mm(When Tiles are laid over existing hard ready surface) In ground floor.
91In first floor.
92In 2nd Floor.
93In 3rd Floor.
94Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600mmX600mmX10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4)and 2mm thick cement slurry backside of tiles using cement @2.91Kg./sqM or using polymerised adhesive (6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removalof wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth up to mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement,synthetic adhesive and grout material to be supplied by the contrr]e) (I) With application slurry @1.75kg / Sq.m, 20mm sand cement mortar (1:4) & 2mm thick cement slurry at backside of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White, In Ground Floor
95In first floor.
96In 2nd Floor.
97In 3rd Floor.
98Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. (c) Area of each Granite slab above 1.00 Square meter. (In Ground Floor)
99in 1st Floor.
100in 2nd Floor.
101in 3rd Floor.
102Supplying, fitting & fixing granite slabs 15 mm to 18mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass/copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete.[Using cement slurry at backside of granite @4.4kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] (a) Area of each Granite slab 0.6 to 1.0 Square meter.
103Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone
104Extra cost of labour for Marble Stone Floor in treads of Steps.
105Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (a) Sal : Siliguri G.Floor
106in 1st Floor
107in 2nd Floor
108in 3rd Floor
109Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35mm thick shutters (single leaf)
110in 1st Floor.
111in 2nd Floor.
112in 3rd Floor.
113Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] (ii) 6mm In Ground Floor
114in 1st Floor.
115in 2nd Floor.
116in 3rd Floor.
117Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-in charge.The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre.(i) Thickness of laminate 1.5mm
118In 1st floor.
119In 2nd floor.
120In 3rd floor.
121M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. In ground floor.
122In 1st floor.
123In 2nd floor.
124In 3rd floor.
125M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In 4th floor
126Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. Ground Floor
127M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS:226, IS:808& SP(6)-1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting,metal arc welding conforming to IS:816-1969&IS:1995 using electrodes of approved make and brand conforming to IS:814-2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes,gas and hire charge of all tools and plants and labour required for thework including all incidental chages such as electricity charges, labour insurance charges etc. In 4th Floor
128M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. ii) For other Structural works like galleries etc.
129Supplying, Fitting & Fixing Factory made prelaminated P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm Prelaminated PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer‟s specification and direction of Engineer-in-Charge.
130PVC Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete.
131Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (i) 100 x 75 x 4.0mm.
132Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. (a) With base plate. (i) 165mm grip x 12mm dia rod x 42mm plate x 3.2mm thick.
133Supplying Heavy Duty Aluminium Handle (EBCO Type) (Natural White)
134Anodised aluminium decorative handle (hexagonal / fluted) of approved quality fitted and fixed complete.i) 150 mm plate x 10 mm dia rod x 12 mm hexagonal / fluted.
135Anodised aluminium barrel/ tower/ socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(i) 225mm long x 12mm dia. bolt.
136Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300mm long
137Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete(i) 250mm x 16mm dia bolt
138Supplying, fitting and fixing M.S. clamp for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction.(a) 40mm. X 6mm, 125mm. Length.
139Supplying,fitting & fixing of 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.
140Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white k) Movable door shutter i) Door frame. (Top & sides).
141(A) In 10-12 Micron thickness Annodizing film I) Natural white k)Movable door shutter. ii) Shutter : Top rail.
142(A) In 10-12 Micron thickness Annodizing film I) Natural white k)Movable door shutter. ii) Shutter : Bottom rail.
143(A) In 10-12 Micron thickness Annodizing film I) Natural white k)Movable door shutter. ii) Shutter : Lock rail.
144(A) In 10-12 Micron thickness Annodizing film I) Natural white k)Movable door shutter. ii) Shutter : Door vertical.
145(A) In 10-12 Micron thickness Annodizing film I) Natural white k)Movable door shutter. ii) Shutter : Glazing cleap.
146Fixed glazing i) Top, bottom and side member.
147ii) Mullion.
148iii) Glazing clip
149Louvered window: (A) In 10-12 Micron thickness Annodizing film, I) Natural white, h.(i) Top, bottom and side member
150ii) Louvered Section
151iii) Cleat angle ( Non-annodized)
152Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.b) 'U' shaped EPDM gasket for frames.
153Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. iii) weather gasket / wool pile for door vertical.
154Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections ii)Fixed glazing
155Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- B) Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. Ground Floor
156Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections v ) Louvered window In Ground Floor
157In First Floor
158In Second Floor
159In Third Floor
160Supply and fitting of Door stopper (brass)
161Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.i)5mm thick clear glass.
162Wall panelling / partition with Melamine faced 3 layered flat pressed wood particle board of approved make and brand as per direction of Engineer - in - Charge of requisite grade bonded with phenol formaldehyde synthetic resin conforming to IS: 848 - 1974 (excluding the cost of supporting frame work and teak wood battens / lipping) (B) Prelaminated particle board conforming to IS: 3087 - 1985 and IS 12823 - 1990. (ii) Both side decorative laminate (b) Interior Grade12mm thick
163Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
164Supplying fitting and fixing white vitreous china best quality approved make wash basin with C.P. brackets on 75mm x 75mm x 75mm wooden blocks, C.P. waste fitting of 32mm dia, one approved quality brass C.P. pillar cock of 15mm dia, C.P. chan with rubber plus of 30mm dia, approved quality PVC waste pipe with C.P. nut 32mm dia, 900mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (iii) 630 mm X 450 mm size
165Supplying, fitting and fixing pedestal of approved make for wash basin (white)
166Supplying, fitting and fixing white vitreous Hindware make (Model-Neo Mini-CAT No.10099) wash basin with Pedestal including all tools and tackles complete.
167Supplying, fitting and fixing Hindware make (Model-ACE Neo P-CAT No.525420) E.W.C. (Size-57.5x35x39 cm) in white glazed vitreous chinaware complete in position with necessary bolts, nuts etc. (a) With 'P' trap
168Supplying, fitting and fixing Hindware make (Model-ACE Neo P-CAT No.525420) 10 litre P.V.C. low-down cistern ( 47.5x14.8x30.5 cm)with P.V.C. fittings complete, brackets including all tools and tackels complete.
169Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (ii) Plastic (hallow type) white
170Supplying, fitting and fixing 32 mm dia. flush pipe of approved make with necessary fixing materials and clamps complete. i) Polythene flush pipe
171Supplying fitting and fixing Multi Floor Trap with Top tile & Strainer 75 mm
172Supplying, fitting and fixing bib cock or stop cock (b) (ii) Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand).
173Supplying, fitting and fixing bib cock or stop cock(ii) Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand)
174Supplying, fitting and fixing bib cock or stop cock(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
175Supplying, fitting and fixing pillar cock of approved make. .e) (i) CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand).
176Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (ii) 750 mm long
177Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (ii) 450 mm long
178Supplying, fitting and fixing shower of approved brand and make.(b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model- Florentine of Jaquar or similar brand)
179Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
180Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work 20 mm dia. PVC pipes
18140 mm dia. PVC pipes for Exposed Work
18225 mm dia. PVC pipes for Exposed Work
18350 mm dia. PVC pipes for Exposed Work
18425 mm dia. PVC pies for Concealed Work
185Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (ii) CPVC Pipes Class-2,SDR-13.5 20 mm dia. PVC pies for Concealed Work
186Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (ii) CPVC Pipes Class-2,SDR-13.5 25 mm dia. PVC pies for Concealed Work
187Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (ii) CPVC Pipes Class-2,SDR-13.5 40 mm dia. PVC pies for Exposed Work
188Ball valve 40 mm
189Ball valve 20 mm
190Ball valve 25 mm
191Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (U) Male threaded adopter (Brass threaded) size 20mm x 15mm
192Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (V) Female threaded adopter (Brass threaded) size 20mm x 15mm
193Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (W) Female Elbow (Brass threaded)
194Supplying, fitting and fixing Waste fittings complete.(a) C.P. over brass (ii) 32 mm
195Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass ii) 25 mm dia. and 750 mm long
196Supplying, fitting and fixing glass shelf with aluminium guard rails. a) Ordinary type with 5.5 mm sheet glass (ii) 600 mm X 125 mm
197Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
198Supplying, fitting and fixing Tooth brush and Tumbler holder of approved make of size 140 mm X 65 mm (porcelain).
199Supplying, fitting and fixing liquid soap container. (a) Cromium plated.
200Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent)
201Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm
202Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a) 75 mm
203Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (c) 160 mm
204(ii) Plain Tee (b) 110 mm
205(ii) Plain Tee (a) 75 mm
206(iii) Door Tee(b) 110 mm
207(iii) Door Tee (a) 75 mm
208Plain Y (b) 110 mm
209Plain Y (a) 75 mm
210Bend 87.5º (b) 110 mm
211Bend 87.5º (a) 75 mm
212Door Bend (T.S.) (b) 110 mm
213Door Bend (T.S.) (a) 75 mm
214Vent Cowl (b) 110 mm
215Pipe Clip (b) 110 mm
216Pipe Clip (a) 75 mm
217110 X 110 P Trap75 mm
218Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground (i) 110 mm dia.
219(A) Above ground (i) 160 mm dia.
220(A) Above ground (i) 75 mm dia.
221(B) Under ground (ii) 110 mm dia.
222(B) Under ground (ii) 160 mm dia.
223(B) Under ground (ii) 75 mm dia.
224Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) multilayer. i) 5000 litre Capacity.
225Labour for hoisting P.V.C. water storage tank. i) Above 1500 litre upto 5000 litre capacity.(a) Upto 4th story from G.L
226Labour for punching hole in P.V.C. water storage tank upto 50mm dia.
227Supplying fitting and fixing gunmetal wheel valve of approved brand bearing I.S.I. marking with fittings(tested to 21 Kg./sq.cma)(ix) 15mm
228viii) 20mm
229vii) 25mm
230vi) 32mm
231v) 40mm
232iv) 50mm
233(i) 100 mm dia
234Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. BracketsSink with drain board 1050 mm X 450 mm X 180 mm
235CP Sink Cock with Regular Swinging Spout (Table Mounted Model)(Equivalent to Code No. 5357 of JAQUAR or similar brand).
236Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm(depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materialsWith Bazree (N.B Variety) (SAIL/TATA/RINL
237Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar(4:1) including two 560mm dia R.C.C. manhole cover(heavy type) of approved make supplied, fitted and fixed in the 100mm thick RCC(3:1.5:1) top slab with necessary fittings. 20 mm thick cement plaster(4:1) with neat cement finish to the internal surface and 15 mm thick cement plaster(4:1) to out side wall up to 200mm below G.L. floor finished with 25mm thick grey artificial stone over 100mm thick RCC(3:1.5:1) bottom slab including supplying, fitting and fixing all necessary special fittings, S.W. tees, C.I. foot rest etc. including excavating earth in all sorts of soil shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tank with earth removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including construction attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring to be done with admixture of water proofing compound @ 0.5% by weight of cement with all cost of labour and materials a) With Bazree (N.B Varity) (SAIL/TATA/RINL) i) For 50 users.
238Construction of circular soak well 2.50 m deep with all types of sandy soils with dry brick work upto 1.60 m from the bottom having 150mm intermediate cement brick work (4:1) band all round and cement brick work(4:1) band all round and cement brick work(4:1) upto 0.90 m from the top with 20 mm thick cement plaster (4:1) inside face upto the depth of cement brick work, 15mm thick cement plaster(4:1) on outer face from top of the well upto G.L. and 6mm thick cement plaster(4:1) on top of the RCC cover slab including filling bottom 1.0m of inside of the well with brick metal(50mm to 63mm size) including RCC cover slab of 100mm thick with cement concrete(3:1.5:1) with stone chips with necessary reinforcement and shuttering including one 560mm dia. RCC manhole cover (heavy type) of approved make supplied fitted and fixed in the cover slab with necessary fittings making necessary arrangements for pipe connection, excavation of well including shoring, dewatering and removing the excess earth from the premises as per direction of complete in all respect with all cost of labour and materials. With 250mm thick dry brick work and 250mm thick cement brick work(6:1) and 1.0m inside dia.(SAIL/TATA/RINL)
239Supplying, fitting and fixing PTMT Smart Shelf of approved make of size 300 mm.
240Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm dia rod complete including mending damages. Payment for damage and repair to be made separately.
241Roof treatment by application of non toxic polyurethane modified acrylic based single component (P U Roof Coat) solvent free, cold applied polyurethane modified elastomeric waterproofing membrane with excellant UV resistant capasity as per ASTM D6083 (a water based 100%acrylic elastomeric emulsion polymer latex coating used as protective coating for roofs) after preparing the surface by cleaning and ti repairing the roof cracks by cement & sand mortar (1:4), preferably with antishrinkage mortar (to be paid separately) if any, apply two coats along with a Primingcoat(two coats of P U Roof Coat and one coat of primer coat compatible with main product as per manufacturers specification) and reinforced with or without 20 gsm GeotextileFleece, including the cost of primer coat and basepreparation, tools & IPlantsbut excluding the cost of scaffolding and stagging complete as per direction of Engineer -in-charge.
242Supplying and laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks (with concrete grade as specified as per table I of IS 15658:2006) manufactured in steel mould clamped to a vibrating table by hydraulic pressure (as per cl no. 6.30 of IRC : SP 63 (2018), from BIS license manufacturer, with spacer nib (small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per Cl. no. 3.26 of IS 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per cl no. 3.3 of IS 15658) as per table 2 of IS 15658 with flexural strength/breaking load as per Annexure G of IS 15658, on the prepared base course of specified CBR as per table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP 63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per clause 8.7 of IRC SP 63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edges. 80mm thick, Color Decorative
243Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UVrays, Non-fade,High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS:4457-2007 and tested in accordance with IS:13630 [Non-modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness>7.0, Staining resistance:Class-1,WaterAbsorptionE<0.5%], MOR >38 N/sq.mm & Breaking strength >4000N for Outdoor area of building e.g. Driveway, Pathway,Pavements,Parking lots,Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2mm thick cement slurry at backside of tiles using cement @2.91Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials,labour and all other incidental charges complete including backside slurry and true to the manufacturer's specification and direction of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm
244Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(ii) 20 mm dia bolt. (a) 300 mm long
245Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:- a) With 0.5 mm thick sheet
246Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping) (b) 300 mm. wide gutter
247b) Development of Bore well and sinking submersible pump Site Preparation, Temporary Latrine, Placement & levelling of Rig Machine, Mast hoisting and Casing drilling (Upto 6 mtr.) Placement of Casing with all allied works necessary to commence drilling woks and wind up of all machineries after completion of Drilling.
248Drilling by Reverse Rotary method of drilling using 9 7/8” dia.bit for pilot bore follwed by subsequently reaming using 12 1/4” dia. ,15 \\" dia. and 17.5\\" dia. Rock Roller Bits/ Drag Bits in consolidated, semi consolidated and soft formation up to required depth including casing boring and casing lowering as required including cost of fuels and lubricants etc. as required for drilling.From 6 Mtr. to 60 Mtr.
249From 60 Mtr. to 90 Mtr.
250Transportation cost of drilling equipment and accessories rig machine etc. including cost of fuel,Lubricant & loading unloading the materials from store/stack yard /suppliers godown and unloading /stacking the same at site. (Upto 60.0 km distance)
251Cost of Consumables (Bentonite, lubricants etc. complete in all respect) for drilling rigs and machineries.
252Development (Min. 8 Hr. continuous or until clear water whichever is greater) of tube well by using suitable air compressor (Min. Capacity: 600CFM & operating Pressure 14 Bar) followed by yield testing with BHT pump (Head :45 to 50mtr.,Discharge :1100 to 1000 LPM and 25 BHP engine) all complete including To & Fro Transportation cost and Cost of fuels, lubricants & Labour etc.
253Supply and delivery at site UPVC pipe (CM) conforming to IS: 12818:2010 (CIPET certified).c) 200mm dia
254b) 150 mm dia.
255Supply and delivery of UPVC Reducerc) 200mm x 150 mm dia.
256Supply and delivery at site UPVC pipe Deep well screen (RDS) pipes with ribs at site conforming to IS: 12818:2010 (CIPET certified).c) 150 mm dia
257Supply and delivery of MS TW Specials (Clamp, UPVC End Cap, Bail plug, Lugs, Ring etc.) complete.
258Supply and delivery of M.S .Centre guide (Special Type).
259Supply and delivery of M.S. Housing clamp with UPVC TOP cap dia. complete.
260Supply and delivery of Washed gravels size ranging from 1.80 mm to 4.74 mm. conforming to IS 4097 : 1967.
261Lowering the tube well assembly (UPVC Casing pipe ,well pipe, Submersible pump, strainer along with UPVC accessories) vertically in a position with proper lowering arrangement by applying necessary jointing compound including labour cost for subsequent gravel packing and machine operation cost etc. The cost includes opening of old Borewell, taking out sumbmersed pump & refixing the pump to new bore well, commissioning of Pump & Borewell system including all cost complete in all respect.
262Electro-logging charge.
263Supplying and fixing of 2.5 sqm 3 core copper flat submersible cable as per IS 694:1990 with ISI mark) etc. complete.
264Supply fitting fixing column pipe , Make: Skipper or Equivalent, SP Heavy, Pressure Rating 35 kG/cm2 complete in all respect including necessary fittings complete in all respect. (a) 50mm dia
265(b) 65mm dia
2668mm dia PVC coated steel Rope for protection of Pump Set
267Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
268Supplying and fitting fixing following valves and specials (i) 80 mm dia. C.I. Diaphragm valve as per I.S. Specification
269Supplying and fitting fixing following valves and specials (i) 65 mm dia. Non Return valve as per I.S. Specification
270Supplying, fitting, fixing of Kirloskar or other approved make of submersible pump motor set (Model No Gold 3/VII/ as per approved ) 2.00 H.P,3-Ph., 415 V with PVC submersible cable (1 x 3 x 1.5 Sq.mm) 30 mtr long with specified control panel for D.U.L. starter for the said amp set, supporting clamps with nuts and bolts ,tube well cover etc. complete as per direction of E.I.C.
271Supplying fitting , fixing of 2000 LPH iron elimination plant with Indian filter media including all necessary accessories and chemicals all complete.
272Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).(i) 80 mm dia
273(ii) 65 mm dia
274(iii) 50 mm dia
275Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately)(a) For Exposed Work PVC Pipes80mm
27665 mm
27750 mm
27840 mm
27932 mm
28025 mm
281Supply of UPVC pipe fitting conforming to As Per ASTM D-1810 Male threaded adopter (Brass Threaded) (i) 80 mm
282(ii) 65 mm
283(iii) 50 mm
284Any other Items covering in PWD SOR (Building works) and PWD SOR (Sanitary & Plumbing Works), PWD SOR (Road and bridge works) and PHE SOR w.e.f 01.11.2017 with latest corrigenda.
285Add BOWCESS@1%
286B) ELECTRICAL WORKS: Distribution wiring in1.1kV grade 22/0.3 (1.5sqmm) single core stranded \\"FRLS\\" PVC insulated and unseathed single core copper wire (approved make) in suitable size PVC casing caping (precision make) wtih 1 x 22/0.3 single core stranded \\"FR\\"PVC insulated and unseathed single core copper wire for ECC including necessary PVC clips, fittings etc. to light/fan/callbell points with piano key type switch anchor make fixed on sheet steel fabricated switch board with perspex/bakelite top cover on wall incl. necessary connections and making earthing attachment and mending good damages to building works.b) Average run 6 mts
287c) Average run 8 mts
288d) Average run 9 mts
289Distribution wiring in1.1kV grade 22/0.3 (1.5sqmm) single core stranded \\"FRLS\\" PVC insulated and unseathed single core copper wire (approved make) in suitable size PVC casing caping (precision make) wtih 1 x 22/0.3 single core stranded \\"FR\\"PVC insulated and unseathed single core copper wire for ECC including necessary PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch anchor make fixed on sheet steel fabricated switch board with perspex/bakelite top cover on wall incl. necessary connections and making earthing attachment and mending good damages to building works.b) Average run 4.5 mts
290c) Average run 6 mts
291Wiring in1.1kV grade single core stranded \\"FRLS\\" PVC insulated and unseathed single core copper wire (approved make) in suitable size PVC casing caping (precision make) including necessary PVC clips, fittings etc.a) 2 x 2.5 sq.mm + 1 x 1.5 sq.mm.
292a) 2 x 4.0 sq.mm + 1 x 2.5 sq.mm.
293Supplying and fixing PVC casing-capping recision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works(b) 25x10mm Size
294Supply and fixing GI modular Switch Board of the following sizez complete with three no. suitable size copper bar with holes (for Ph, N &E ) fixed on bakelite/Hard rubber insulator over MS welded chairs incl. top Cover flushed in wall for housing the board after cutting the brick wall incl making good dameges to building works.(a) 4 Module
295(b) 6 Module
296(c) 8 Module
297(d) 12 Module
298(f) 2 row18 Module
299Supply and fixing of 4 moudle top cover plate
300Supply and fixing of 6 moudle top cover plate
301Supply and fixing of 8 moudle top cover plate
302Supply and fixing of 12 moudle top cover plate
303Supply and fixing of 2 row 18 moudle top cover plate
304Supply and fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate nd making necessary connections as required.
305Supply and fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate nd making necessary connections as required.
306Supply and fixing 240 V, 6 A 5 pin modular type plug socket (Brand approved by EIC) without switch and plug top on GI Modular type switch board having top cover plate nd making necessary connections with PVC cu wire and earth continuity wire etc.
307Supply and fixing 240 V 16 A 5 pin modular type plug socket (Brand approved by EIC) without switch and plug top on GI Modular type switch board having top cover plate nd making necessary connections with PVC cu wire and earth continuity wire etc.
308Fixing only bulkhead ceiling fitting on wall/ceiling with screws etc.
309Supplying and fixing 240/415V MCB of breaking capacity 10 kA & C characteristics on din rail of existing DBs and necessary connection 6-32 A SP. Legrand Make.
310Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+12 way
311Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V 100 A DP with fuse on L&N Make:(Havells/C&G/ or EIC Approved)
312Earthing with 50mm dia GI pipe 3.64mm thick x 3.04 mtr long and 1 x 4 SWG GI (Hot Dip) wire (4 mtr long),13mm dia x 80mm long GI bolts,double washers including supplying and fixing 15 mm dia GI pipe protection (1 mtr long) to be filled with bitumin partly under the ground level and partly above the ground level driven to an average depth of 3.65 mtr below the ground level and restoring the surface duly rammed . b) Morrum Soil
313Connecting the equipments to earth busbar including supplying and fixing 20 mm X 3 mm galvanised (hot dip) MS flat on walll/ floor with gi saddles as required and connections to equipments incl. drilling holes, with bolts, nuts, washers etc.
314SConnecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (v) No. 12 SWG
315Supply of VENTIL AIR DX WHITE,SWEEP 250 MM Exhaust Fan Make: Crompton/Philips/Havells/equivalent Make as per the approval of EIC
316Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
317Supplying and fixing 240 V AC/DC superior type Ding-Dong call bell (Anchor) on HW board incl. S&F HW board
318Supplying of Ceiling fan 48'' (Havells)
319Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire
320Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
321Supply and fixing Angel holder with 15W LED Lamp
322Supply & Fixing of Battens type LED Tube Light 1 x 1 (22 watt) (Havells/C&G/Philips or EIC Approved)
323Supply & Fixing of fabrication wall mounting indoor type pannel BOX, (16swg) 415V I/C 200 AMP TPN with HRC Fuse with copper bus bar chamber 3 pics Indicator, I pcs Volt Meter, I pcs amp Meter, 1 pcs Volt selector, 8 Pcs 63 Amp, DP O/G MCCB Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57184591
AUTHORITY Government Departments
TENDER VALUE 2.19 Crore
LAST DATE 24-09-2026
Authority
Authority Name West Bengal State Electricity Distribution Company Limited
Work Description Tender for Construction Of Four Storeyed B- Type Quarter Along With Sanitary, Plumbing And Internal Electrification, Development Of Quarter Premises, Development Of Bore Well By Reverse Rotary Method, Sinking Submersible Pump And Installation Of 2000 Lph Iron Elimination Pump For The Proposed B-Type Quarter At Powerhouse Complex, 2Nd Mile, Siliguri Under Hydel Headquarters.
Basic Detail
Tender No WBSEDCL/CEH/C/26-27/06 dtd 18.08.2026
Bidding Type Tender
Location
City Darjeeling
State West Bengal
Key Dates
Publish Date 25 Aug 2026
Submission Date 24 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 2.19 Crore
Tender Fee Ref. Documents
EMD 4.39 Lakhs
Exemption Available
Document List
BOQ_2551454.xls
edbcdb04-9abc-4472-b814-3e948ff9d98f.html
Tendernotice_1 (30).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2551454.xls

html

edbcdb04-9abc-4472-b814-3e948ff9d98f.html

pdf

Tendernotice_1 (30).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders