Tender For Indri Town - Procurement, Installation And Commissioning Of Online Multiparametric Cod, Bod, Tss, Ph A,Onia, Nitrate Dissolved Oxygen And Mlss Analyzer With Data Transmission To Cpcb/ Hspcb Portal With Iot Device With Sensor (Cod, Bod, Tss
Tender Overview
Project Description
Tender for Indri Town - Procurement, Installation And Commissioning Of Online Multiparametric Cod, Bod, Tss, Ph A,Onia, Nitrate Dissolved Oxygen And Mlss Analyzer With Data Transmission To Cpcb/ Hspcb Portal With Iot Device With Sensor (Cod, Bod, Tss) (Ph, Amonia Nitrate) (Dissolved Oxygen) And Cable Terminal And All Other Works Contingent Thereto At 4 Mld Stp In Indri Town Distt. Karnal .
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Public Health Engineering Division No. 2, Karnal Name of work:- :Indri Town - Procurement, Installation and commissioning of online Multiparametric COD, BOD, TSS, PH A,onia, Nitrate Dissolved Oxygen and MLSS Analyzer with Data Transmission to CPCB/ HSPCB portal with IOT Device with sensor (COD, BOD, TSS) (PH, Amonia Nitrate) (Dissolved Oxygen) and cable terminal and all other works contingent thereto at 4 MLD STP in Indri Town Distt. Karnal . Contract No: Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Specifications Item / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder inRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | DISSOLVED OXYGEN ANALYZERTechnical Specifications for Controller: Max. number of sensors: 01 Communication: 2 x RelaysDisplay: Graphic TFT Display:Resolution: 320 x 240 pixel: backlitElectric Supply: 100 … 240 VAC (50/60 Hz)USB interface: USB-A for software updates Ambient Conditions: -20 °C … plus 55 °CProtection Rating: IP 67 / corresponding to NEMA 4X Electromagnetic Compatibility: EN 61326-1, Class A: FCC Class AIntegrated Overvoltage Protection: According to EN 61326-1 enhanced overvoltage protection for the entire systemTechnical Specifications for DISSOLVED OXYGEN Sensor:Measuring method: OpticalMeasuring range (25 °C): (0 20.00 ppmResolution: 0.01 ppm Accuracy: ±0.1 mg/l (ppm)Response time at 25 °C: 60 sTemp. compensation: -5 °C plus 50 °CPressure Resistance: 10 bar (incl. sensor connection cable)Operating temperature: (0 50 °C)Electromagnetic Compatibility: EN 61326, Class B, FCC Class A:Intended for indispensable operation Mechanical MOC: Sensor cap,fixation: POM, PVC, silicone, PMMAsensor body: VA stainless steel 1.4571 protection type IP 68Sensor Cable: Sensor adapter cable for all IQ sensors, with IP 68waterproof connection to the IQ SENSOR NET system. Cable length 7 m |
| 3 | DISSOLVED OXYGEN ANALYZERTechnical Specifications for Controller: Max. number of sensors: 01 Communication: 2 x RelaysDisplay: Graphic TFT Display:Resolution: 320 x 240 pixel: backlitElectric Supply: 100 … 240 VAC (50/60 Hz)USB interface: USB-A for software updates Ambient Conditions: -20 °C … plus 55 °CProtection Rating: IP 67 / corresponding to NEMA 4X Electromagnetic Compatibility: EN 61326-1, Class A: FCC Class AIntegrated Overvoltage Protection: According to EN 61326-1 enhanced overvoltage protection for the entire systemTechnical Specifications for DISSOLVED OXYGEN Sensor:Measuring method: OpticalMeasuring range (25 °C): (0 20.00 ppmResolution: 0.01 ppm Accuracy: ±0.1 mg/l (ppm)Response time at 25 °C: 60 sTemp. compensation: -5 °C plus 50 °CPressure Resistance: 10 bar (incl. sensor connection cable)Operating temperature: (0 50 °C)Electromagnetic Compatibility: EN 61326, Class B, FCC Class A:Intended for indispensable operation Mechanical MOC: Sensor cap,fixation: POM, PVC, silicone, PMMAsensor body: VA stainless steel 1.4571 protection type IP 68Sensor Cable: Sensor adapter cable for all IQ sensors, with IP 68waterproof connection to the IQ SENSOR NET system. Cable length 7 m Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender