Tender For special Repair/Replacement Lt Overhead Conductors Into Underground Lt Cable Including Connected Items At Half Moon Line Area Under Ge Ranikhet
Tender Overview
Project Description
Tender for special Repair/Replacement Lt Overhead Conductors Into Underground Lt Cable Including Connected Items At Half Moon Line Area Under Ge Ranikhet
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Sep-2026 | CorrigendumNo1 | BOQ | 15-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking out unserviceable LT cable of any type and size from pole/wall/trenches by disconnecting electric connections for repair/ replacement of cable complete all as specified and directed. |
| 2 | Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and not exc 1.5 m in depth for laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed. |
| 3 | Returning filling in incl spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed. |
| 4 | Removing excavated material to a distance not exc 15 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 5 | M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed. |
| 6 | M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75) mm all as specified and directed. |
| 7 | M&L for GI pipe light grade with all fittings fixed to pole and laid to floor/underground/under road for mechanical protection of cable of the following sizes :- (a) 80mm bore |
| 8 | (b) 40mm bore |
| 9 | Supply, laying, jointing and commissioning in repairs LT XLPE 1100 volts grade heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on pole and roads etc of following sizes :- (a) 185 Sqmm 3.5 core |
| 10 | (b) 150 Sqmm 3.5 core |
| 11 | (c) 95 Sqmm 3.5 core |
| 12 | (d) 70 Sqmm 3.5 core |
| 13 | (e) 50 Sqmm 3.5 core |
| 14 | (f) 25 Sqmm 4 core |
| 15 | (g) 16 Sqmm 4 core |
| 16 | (h) 16 Sqmm 2 core |
| 17 | Dismantling of existing LT pole any size/type from foundation in necessary earth work including dismentling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed. |
| 18 | Dismantling of existing stay assembly any type/size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed. |
| 19 | Dismantling/taking out old ACSR/copper conductor/GI wire any size from existing over head lines incl disconnection all as specified and directed. |
| 20 | Dismantling/taking out insulator of any size/type from existing electric LT lines all as specified and directed. |
| 21 | Supply and fixing Junction Box made up of High quality thermoplastic polycarbonate enclosure with IP 65 degree of protection, weather proof, corrosion proof, dust proof, insulted and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal of size 200x160x98 mm of make hensel or equivalent make of Sintex/ Universal complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & fixing of Nature Switch Smart Timer based Automatic Street Light Control Panel. The Panel should be suitable enough to take Single-phase load of 8kW. Nature Switch Smart Timer should be maintenance-free in design and settings accessible via a Mobile App (with Bluetooth connectivity). The Mobile App should allow users to customize the ON & OFF timings based on Natural Light (sensor), Local Sunset/Sunrise (Astro) and Time. The Mobile App should also have facility to set Input Voltage range. The Smart Timer along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Enclosure conforming to IP54. The circuit should also have provision for Manual Operation (i.e. Sensor By-Pass option) The Circuit should be suitable enough to take Single-Phase load of 8kW ( model: Navdeep-54-8kW1P) with Contactor, Incoming MCB & Outgoing MCB rating of 40 Amps & main load Circuit Wiring (Copper) of min. 10 sq.mm. Make – SWADEEP/Indo Asian/L&T or equivalent approved make complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. |
| 23 | Supply, fabricating and fixing of sheet metal enclosure made of 16 gauge MS sheet outdoor type of suitable size including fixing of MCCB of cap 250 Amp, 415 Volt,50Hz, 4 pole, 36 KA, AC supply with 300 Amp rated busbar on porcelain insulators for neutral link double door type with locking arrangement complete with MS angle iron frame of size 25 x 25 x 5mm with nut/bolts and PCC plateform work including painting with two coat of synthetic enameelled paint over one coat of red oxide/ primer complete all as specified and directed at site. |
| 24 | Supply, fabricating and fixing of sheet metal enclosure for bus bars made of 16 gauge MS sheet outdoor type of suitable size (1000x800x650mm) with three nos 300 Amp rated aluminium busbar and one number 250 Amp aluminium busbar with provn for terminals for connecting at least 6 Nos outgoing cables on bus bar for distribution on porcelain insulators for neutral link double door type with locking arrangement and holes of required size for cable in and out complete with MS angle iron frame of size 40 x 40 x 5 mm with nut/bolts and PCC plateform work including painting with two coat of synthetic enamelled paint over one coat of red oxide/ primer complete all as specified and directed at site. |
| 25 | Supply, fabricating and fixing of sheet metal enclosure for bus bars made of 16 gauge MS sheet outdoor type of suitable size (1000x800x650mm) with three nos 200 Amp rated aluminium busbar and one number 150 Amp aluminium busbar with provn for terminals for connecting at least 4 Nos outgoing cables on bus bar for distribution, on porcelain insulators for neutral link double door type with locking arrangement & holes of required size for cable in and out complete with MS angle iron frame of size 25 x 25 x 5 mm with nut/bolts and PCC plateform work including painting with two coat of synthetic enameelled paint over one coat of red oxide/ primer complete all as specified and directed at site. |
| 26 | M&L for GI Brackets bending & shaping of size 32/40 mm dia galvanised iron pipe light grade over all length 0.60 mtr including necessary 02 Nos clamps, brackets and bolts etc to fixing on tublar/RCC pole including taking down old u/s GI brackets. |
| 27 | Supply and laying PVC cable along with earth wire with the size of 2 x 2.5 sq. mm +1 x 2.5 sq. mm earth wire of FR-LSH PVC insulated copper conductor, three core cable as required complete. |
| 28 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender