Rural Development Government Departments Closing in 9 days TDR #57181617

Tender For Construction Of Toilet Blocks For Male And Female With Baby Care Room At Jmfc Court Complex, Sinapali_Building

Issued by Government Departments · Nuapada, Odisha
Tender Value
19.66 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
9 days left
EMD
19666
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nuapada → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Toilet Blocks For Male And Female With Baby Care Room At Jmfc Court Complex, Sinapali_Building

BOQ

Name of Work:- Construction of toilet blocks for male and female with baby care room at JMFC Court Complex, Sinapali_Building
Sl. No. Item Description
1Earth work in excavation of foundation in hard soil with all lead & lift including dressing & levelling the bed of the foundation to the required width & depth & stacking the excavated materials away from the working areas as per the direction of E.I.C.
2Supplying, filling in foundation and plinth with sand in layers not exceeding 23cum (9\\") thick including watering and ramming with the cost, conveyance, royality, taxes of all materials, labour, T & P required for the Work etc. complete as per specification and direction of the Engineer-in-Charge.
3Cement Concrete of proportion (1:3:6) in foundation and floors using 4cm (3/2\\") size clean hard black broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6\\") thick to the required level ramming watering and curring etc. complete including cost and conveyance of all materials with all taxes and royalities and all labour with T & P required for the work etc. complete including dewatering if required as per specification and direction of the Engineer-in-Charge.
4Brick work with Fly Ash Bricks 25 cm x 12 cm x 8 cm size having crushing strength not less than 75 Kg/Cm2 with dimensional tolerance +/- 8 percent in cement mortar (1:6) in Foundation & Plinth etc. complete as per specification and direction of the Engineer-in-Charge.
5Brick work with Fly Ash Bricks 25 cm x 12 cm x 8 cm size having crushing strength not less than 75 Kg/Cm2 with dimensional tolerance +/- 8 percent in cement mortar (1:6) in Superstructure etc. complete as per specification and direction of the Engineer-in-Charge.
6Cement concrete (1:2:4) using 12mm hard granite crusher broken metal including all cost , carriage, royality, taxes, and all labour involved for completion of item of work as per the direction of Engineer- in - charge.
7Providing and laying RCC M-20 grade using 20 mm and downgraded size hard black broken granite stone chips of approved quality and from approved quarry including hoisting, lowering and laying concerete and compacting by using vibrators watering and curring for 4 weeks centering and shuttering and finishing the exposed surface smooth providing grooves of beads where necessary including cost, conveyance, royalities and taxes of all material and labour required for the work etc. complete excluding cost and conveyance of M.S. Rod or steel and binding wires of 18 to 20 guage and labour charges for straightening, cutting etc of the M.S. rods or tor steel and tying grills and placing in proper position as per specification and direction of the Engineer-in-charge. work with minimum compressivee strength in work test of 150kg/cm2 in 15cm cum cubes at 28 days cost and conveyance of M.S. Rod or steel and binding wires of 18 to 20 guage and labour charges for straightening, cutting etc of the M.S. rods or tor steel and tying grills and placing in proper position as per specification and direction of the Engineer-in-charge. 7.10:-Column Base & Footing
8Column up to Plinth beam level
9Plinth Band
10Column & Beam
11Roof Beam
12Lintel Beam
13Chajja
14Roof Slab
15Straightening bent up or coiled rods cutting bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor steel and binding wires and tying the grills hoisting lowering and placing in proper position as required for RCC works with cost, conveyance and taxes of M.S. Rods or Tor steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge. (Weight of binding wires will not be considered for payment and payment will be made on weight of M.S. Rods or Tor steel only).
16Supplying, fitting and fixing of M.S. windows and door shutters and collapsible gate with top and bottom rails in proper position including cost, conveyane, royalty and taxes of all materials, T & P articles requried for the work etc complete as per specification and direction of the Engineer-in-Charge.
17Labour for fitting and fixing of M.S. windows and door shutters and collapsible gate with top and bottom rails in proper position including making holes in walls in proper position including making holes in walls RCC structure and wood work etc. and making good to the damages to walls or RCC structures including mending, or cutting to sizes or grooves in walls and fixing with RCC (1:2:4) with hard black broken granite stone chips of 12mm to 20mm (1/2\\" to 3/4\\") (20mm not to exceed 25% ) with cost, conveyane, royalty and taxes of all materials, labour, T & P articles requried for the work etc complete as per specification and direction of the Engineer-in-Charge.
18Supplying, fitting & fixing of WPC type door for toilet with laminate as per specification including cost of all materials and labour charges.
19Providing 16 mm thick cement plaster (1:6) finished smooth to inside surface of brick walls after racking out the joints including watering and curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalties etc. complete in all respect as per specification and direction of the Engineer-in-Charge.
20Providing 12mm thick cement plaster (1:6) finished smooth to outside brick walls after raking out the joint including watering and curring with cost and conveyancec of all materials and labour with T & P required for the work with all taxes and royalities etc. complete in all respect as per specification and direction of the Engineer-in-Charge.
21Fixing vetrified tiles in floors of size 600 mm x 600 mm on 25 mm thick bed of cement morter (1:1) joined with neat cement slurry mixed with pigment to match the shades of the tiles incl. rubbing and polishing complete incl. cost of tile etc all complete.
22Fixing vetrified tiles in Dados on 12 mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shades of the tiles incl. rubbing and polishing complete incl. cost of tile etc all complete.
23Finishing surface of walls with one coat of cement based wall putty (water based ) ,cement primer & plastic emulsion paint of approved make & finished smooth & even surface to receive painting including cost of scaffolding staging charges with cost of all materials , taxes , labour with T & P etc. complete as per E.I.C.
24Wall painting 2 coats with plastic emulsion paint over a coat of primer of approved shade on new work to give an even shade.
25Finishing walls with weather coat of approved shade on new work two coats to give an even shade including cost of paint.
26Painting two coats of enamel paint to new wood work and iron work including cost of paint, sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge.
27Fixing marble tiles (above 0.4 sqm to 1.0 sqm) in treads & steps on 25 mm thick bed of cement morter (1:1) joined with neat cement slurry mixed with pigment to match the shades of the tiles incl. rubbing and polishing complete incl. cost of tile etc all complete.
28EIectrical (EI)Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Havels /HPL/ V Guard )a) -do- Group A
29-do- Group B
30Recessed wiring to Fan Point in-do- Group B
31Recessed wiring to Exhaust Fan Point in -do- Group B
32S/F of Angle holder replacing Ceilling Rose (1.29-1.28)
33S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof.
34Switch BoardsS/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
35S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required.
36S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
37S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & Mini DP MCB, connection, painting etc as required for AC
38S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection
392 Modular box with base & cover
404 Modular box with base & cover
418 Modular box with base & cover
4212 Modular box with base & cover
43Sub-Main2x1.5+1x1.5 (1.8.1)
442x2.5+1x1.5 (1.8.2)
452x4+1x1.5 (1.8.3)
462x6+1x2.5 (1.8.4)
47Inverter wiring (1x1.5smm) Copper wire (1.19.1)
48Circuit Breakers & BDBS/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)
49S/F of 'B/C/D' series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)
50S/F of MCB 8 way Single door (2.3.2)
51Main switchesS/F of 63A ICDP main switch with MS box of 250mmx300mmx60mm deep ( (2.15A)+(1.24.16 )
52EarthingEarthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2)
53Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17)
54FittingsProviding & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/wall or side of the table/door etc as required.(1.31)
55S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
56S/F of 18-25 wt. LED single strip tube. Light fittingwith all accessories & connection (make Havels/HPL/Crompton/Polycab/PAC)
57S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- HS /Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS)
58S/F of 400mm Wall fan with all accessories and connections (Make-Usha-Maxx Air Ultra/Polycab-Arey HS/Cropmton-WM Hiflowave/ Havells-Accelero HS/ Anchor-Altrix HS- OWH/ Orient-Wall43/ Great White-WYNO WF)
59S/F of 20-25 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells )
60S/F of 12w Watt LED Bulb
61PH WorkSupplying all materials,labour,T&P and fitting & fixing of 4.0 kgf/cm2 U-PVC soil waste ventilating pipes and fitting of the following O.D conforming to ISI No.13592/1992 to walls with nails bobbins and wooden plugs or earth work in excavation in all kinds of soil for laying in trenche including jointing with supply of approved rubber lubricant by non-heat application method/as per manufactures specification including tasting and refilling and trenches as per direction of E.I.C.(43.10) 110mm dia.U-PVC SWR pipes
62(b)110mm dia.U-PVC P-trap
63(k)75mm dia.PVC SWR Plain Tee
64(c)110mm dia.U-PVC SWR Double junction door
65(d)110mm dia PVC SWR Nahani trap without Jally
66(e)110mm dia.U-PVC SWR plain bend
67(f)110mm dia.U-PVC SWR vent cowl
68(g)125mm dia CP greatings
69(h)75mm dia.U-PVC SWR pipes
70(i)75mm dia.PVC SWR plain bend
71(j)75mm dia.PVC SWR door bend
72Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking HCI/PVC pipe & fitting etc. all complete as per PH specification and direction of E.I.C.(b)250mm thick wall
73Supplying all materials,labour,T&P and fixing water closet,squatting pan (Indian type W.C pan/Orissa pattern squatting pan)duly embedded in cc(1:5:10)using 4cm size hard granite metal including fixing a pair of vitreous china 250mmx130mmx30mm footrest etc all complete as per specification and direction of the E.I.C.(a)580mm size Orissa pan(Nycer/Cera/Hindware/Parryware)
74Supplying all materials,labour,T&P and fixing wash down water closet(E.W.C)with integral S or P trap to the floor with wooden plug and CP screw including jointing the trap with soil waste pipe in cm(1:1)etc all complete as per specification and direction of the E.I.C.(a)EWC with P & S trap plain (Nycer/Cera/Hindware/Parryware)
75Supplying all materials,labour,T&P and fixing of plastic seat cover for EWC with chromium plated brass hinges and rubber buffer etc all complete as per specification and direction of the E.I.C.
76Supplying all materials,labour,T&P and fixing wash basin with hole for pillar taps with cast iron or M.S. brackets painted white including cutting holes in walls and good the damages etc. all complete as per specification and direction E.I.C.(a)550mmx400mm size WHB(Neycer/Parrywear/Cerra/Hindware)
77Supplying all materials,labour T&P and fitting and fixing 10 Ltrs capacity PVC LL flushing cistern with a pair of CI/MS brackets complete with fittings such as syphonic arrangement,15mm nominal size brass/PVC ball valve with polythene float,CP/Brass handle,unions and couplings for connection with inlet,outlet,over flow pipes,32mm dia PVC flushbend,15mm dia PVC connection pipes including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main with etc all complete as per specification and direction of the E.I.C.(a)10 lit PVC L/L Cistern(Parry ware)
78Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member, 9201 as top, 9200 as bottom and middle member with frame section as 9221 with tapered clip no 4660 and frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board. and as per direction of the Engineer in charge.
79Supplying all materials,labour,T&P and fixing porcelain glazed tiles in floors, on 25mm thick bed of cm(1:1) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C.(a)In Ground Floor
80Supplying all materials,labour,T&P and fixing porcelain glazed tiles in dados/skirtings on 12mm thick CP(1:3)joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing etc. all complete as per direction of the E.I.C.(a)In Ground Floor
81Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the E.I.C.(a) Initial lift up to 1.50m
82(b)From 1.5m to 3.00m depth
83Supplying all materials labour T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction of E.I.C.ST
84Supplying all materials,labour,T&P and providing cc(1:3:6) with 4cm size hard granite metal including watering,curing,conveyance of all materials to worksite,payment of royalty,taxes etc all complete as per specification and direction of the E.I.CST
85Supplying all materials,labour,T&P and providing cc(1:1.5:3)with 12mm size HG chips including watering,curing and conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.S.T.
86Supplying all materials labour T&P and providing brickwork with KB bricks having crushing strength not less than 75kg/cm2 with dimensional tolerance +/-8% including watering,curing conveyance all materials to worksite payment of royality taxes etc. all complete as per specification direction of E.I.C. KB Brickwork in cm(1:4) F&P
87Supplying all materials,labour,T&P and providing cement plaster on brick/stone work including watering, curring and conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.12mm thick CP in cm(1:3)
88Supplying all materials labour T&P and providing cement punning for skirting including watering,curing, conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
89Supplying all materials labour T&P and providing rigid and smooth centering & shuttering for RCC works including falsework and dismantling them after casting including conveyance of all materials to worksite, payment of royality,taxes etc. all complete as per specification and direction of E.I.C.S.T.
90Supplying all materials labour T&P and providing MS reinforcement for RCC works including cutting, bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
91Supplying all materials labour T&P and providing RCC(1:1.5:3)using 12mm hg chips for RCC works including hoisting,laying,watering,curing,conveyance of all materials to work site,payment of royality, taxes etc. all complete as per specification and direction of E.I.C.
92Supplying all materials labour T&P and fixing of RCC baffle wall precast with cc(1:1.5:3)using 12mm bhg chips and fitted to septic tank as per P.H. specification and direction E.I.C.
93Supplying all materials labour T&P and Providing cement flush pointing(1:3) to brick masonary including watering,curing,conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C.
94Supplying all materials,labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C.
95Supplying all materials,labour,T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1st class KB Brickwork in cm(1:6)moulding and shaping the channel inside and benching with cc(1:1.5:3)using 12mm size hg chips,12mm thick CP(1:3)with punning to inside,cement flushpointing(1:3)to outside,RCC cover slab in cc(1:1.5:3)using 12mm size h.g. chips with RCC man hole cover,e.w. in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.(a)Inside size500mm x500mm x 460mm
96(b)Construction of Gully Trap Chamber (0.25 x 0.25 inside Size)
97Supplying all materials, labour, T&P and laying in trenches PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches (to slope or level)and jointing with supply of approved solvent cement by non-heat application method C.C (1:3:6) using 40mm size hard granite metal on bed of the trenches and all round concrete encashing with C:C (1:4:8) using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering, ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C.110 mm dia PVC pipe line (Allround)
98Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast R.C.C rings joined loose gravel backing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.(a)R.C.C Ring Soak way Pit 1.20m dia x 2.00m Deep (Inside Size)
99Supplying all material,labour,T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to IS:15701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts,including hoisting upto a height of 5mtr above GL & placing the tank in required position including conveyance of all materials to worksite,payment of royalty,taxes etc all complete as per PH specification and direction of the E.I.C.(a)1000 lits capacity on the roof
100Supplying all materials,labour,T&P and providing&fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D-1785/89(sch-80)and pipe fittings of the nominal bore with clamps including making good the wall,ceiling and floor all complete as per specification and direction of E.I.C.(a)40mm dia U-PVC Pipe(Internal)
101(b)25mm dia U-PVC Pipe(External)
102Supplying all materials,labour,T&P and cutting holes for taking G.I/PVC pipes and making good the damages as per the direction of E.I.C.(a)In Ground Floor
103Supplying all materials,labour,T&P and cutting holes in RCC,floors,roof,etc.upto 19cm thick for passing GI/PVC pipes and fitting etc. and repairing the holes after insertion of pipes etc. with cc(1:2:4)including finishing complete so as to make it leak proof as per direction of E.I.C.(a)In Ground Floor
104Supplying all materials,labour,T&P and cutting grooves in pucca floor and walls for taking G.I/PVC pipes and making good the damages as per the direction of E.I.C.(a)In Ground Floor
105Supplying all materials,labour,T&P and fixing brass/CP fittings of thefollowing nominal bore with supply of all jointing materials complete as per specification and direction of E.I.C.(Plaza/amber/equivalent )(a)15mm dia CP SB Bib cock
106(b)15mm dia CP Two way Bib cock
107(c)15mm dia CP Angle stop cock
108(d)15mm dia CP Pillar stop cock
109(e)15mm dia Health Faucet & 1.0m long Flexible pipe
110(f)25mm dia PVC F.W.V.
111(g)15mm dia CP Flange
112Supplying all materials, labour, T&P and fixing bowl pattern urinal including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification and direction of the Engineer in charge.Flat Back lipped wall urinal [Medium] 380x580x350l(Parryware/Hindware/Neycer)
11315mm dia Urinal spreder
11415mm dia PVC inlet connection pipe 0.45m long
11532mm dia waste pipe
11632mm dia cp waste Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57181617
AUTHORITY Government Departments
TENDER VALUE 19.66 Lakhs
LAST DATE 08-09-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Construction Of Toilet Blocks For Male And Female With Baby Care Room At Jmfc Court Complex, Sinapali_Building
Basic Detail
Tender No RWKHR-05/2026-27(ONLINE)
Bidding Type Tender
Location
City Nuapada
State Odisha
Key Dates
Publish Date 25 Aug 2026
Submission Date 08 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value 19.66 Lakhs
Tender Fee 6000
EMD 19666
Exemption Available
Document List
0492e67f-75c1-4aef-b801-1296ffae6e98.html
BOQ_607193.xls
Tendernotice_1 (11).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

0492e67f-75c1-4aef-b801-1296ffae6e98.html

xls

BOQ_607193.xls

pdf

Tendernotice_1 (11).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders