Housing Urban and Rular Development Government Departments Closing in 5 days TDR #57181194

Tender For repair maintenance Electrical & Mech. Services At Nes Electrical Division M-251, Delhi. (Sh:-Repair/Renovation Work At Deputy Director (Horticulture) Division East Public Works Department Under Sub Division-3/M2533).

Issued by Government Departments · Delhi, Delhi
Tender Value
16.71 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
5 days left
EMD
33440
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for repair maintenance Electrical & Mech. Services At Nes Electrical Division M-251, Delhi. (Sh:-Repair/Renovation Work At Deputy Director (Horticulture) Division East Public Works Department Under Sub Division-3/M2533).

BOQ

Name of Work:- RMO Elect. & Mech. Services at NES Electrical Division M-251, Delhi. (SH:-Repair/Renovation work at Deputy Director (Horticulture) Division East Public Works Department under Sub division-3/M2533).
Sl. No. Item Description
1Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group (C)
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
42 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
52 X 4 sq. mm + 1 X 4 sq. mm earth wire
62 X 6 sq. mm + 1 X 6 sq. mm earth wire
72 X 10 sq. mm + 1 X 6 sq. mm earth wire
8Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
93 Module (100mmX75mm)
106 Module (200mmX75mm)
118 Module (125mmX125mm)
1212 Module (200mmX150mm)
13Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
14Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
155/6 A switch
163 pin 5/6 A socket outlet
1715/16 A switch
186 pin 15/16 A socket outlet
19Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
208 way (4 + 24), Double door
21Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 amps
22Supplying of 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole
23Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and spreader terminals in existing cubicle panel board including drilling holes in cubicle panel, making connections, ICS=100% ICU and operation of voltage 690v etc. as required.
24100 A, 16 KA, TPMCCB
25Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
26Brush Less Direct Current (BLDC) Fan withRemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
27LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
2836 Watt
29LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5-year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
3036 Watt
31Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drainpipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filtration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.Inverter Type- Cooling only
323.0 TR with 5 Star BEE Rating
33Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5-year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part II 2023. The system shall be able to operate up to 50 0C (outdoor ambient temperature).Inverter Type - Cooling only
342.0 TR with 5 Star BEE Rating
35SITC of Copper wound Automatic Voltage Stabilizer suitable for 2 TR capacity Air Conditioner with High/ Low Voltage trip and time delay relay, input voltage 170-270 Volts etc. as required.
36Supplying of 400 mm dia Wall fan suitable for operation on 230 Volt ± 10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC insulated PVC sheathed copper conductor single core cable etc. as reqd.
37Supplying of heavy-duty exhaust fan of 300 mm sweep, 900 RPM confirming to IS 2312/67 complete with louvers and frames in the existing opening including making the hole to suit the size of the above fan, making good the damage, connections, earthing etc. as required.
38Supply and fixing 3 mm. thick phenolic, Size: 8x4 Feet laminated Hylum sheet cover on existing M.S. Box with brass screw i/c cutting the sheet for existing switch, socket etc. as required.
39Supplying & laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/Open Duct etc. as required.
403 X 10 Sq. mm armounrd Aluminum conductor cable
413.5 X 50 Sq. mm armounrd Aluminum conductor cable
42Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5-year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
43150 Watt
44Supplying and Fixing pole box with hot press mounted SMC pole box of inside dimension 250mm x 250mm x 160mm deep having hinged cover with MS clamp of size 25mm x 5mm flat iron (NS) Nut and bolt washers etc including suitable locking arrangement and 1no.SPMCB with all accessories mounting system and 3 phase aluminum backlight connector 16amp capacity for terminating of 3 phase cable including gasket connection complete etc. as required
45Supplying, Installation, Testing and commissioning of astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
461 output per phase and suitable for single phase supply
47Supplying and fixing of contactor in existing panel.
48Contactors (Minimum: 130 Amps)
49Note:- During the preparation of any running or final bill by the contractor it is essential that the contractor shall submit GST paid invoice, E-way bill and delivery challan for all items without these documents the bill will not be considered submitted in proper form & shall be returned back to the contractor by Junior Engineer (E). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57181194
AUTHORITY Government Departments
TENDER VALUE 16.71 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance Electrical & Mech. Services At Nes Electrical Division M-251, Delhi. (Sh:-Repair/Renovation Work At Deputy Director (Horticulture) Division East Public Works Department Under Sub Division-3/M2533).
Basic Detail
Tender No 65/EE(E)/PWD NES ED/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 25 Aug 2026
Submission Date 31 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 16.71 Lakhs
Tender Fee Ref. Documents
EMD 33440
Exemption Available
Document List
8eae6825-1eb6-4ccb-9a45-29ca5a609829.html
BOQ_396370.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

8eae6825-1eb6-4ccb-9a45-29ca5a609829.html

xls

BOQ_396370.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail