Tender For special Rep To Toilet And Bathroom Of Bldg P-197 And special Rep Of Reinforced Cement Concrete Parapets/Chajjas Of Otm Accn Of 10 Armd And Provn Of Acp Panels To Bldg P-140 At New Mil Stn Kapurthala Under Ge Kapurthala.
Tender Overview
Project Description
Tender for special Rep To Toilet And Bathroom Of Bldg P-197 And special Rep Of Reinforced Cement Concrete Parapets/Chajjas Of Otm Accn Of 10 Armd And Provn Of Acp Panels To Bldg P-140 At New Mil Stn Kapurthala Under Ge Kapurthala.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Spl rep to toilet and bathroom of bldg P-197 and spl rep of RCC parapets/chajjas of OTM Accn of 10 Armd and provn of ACP panels to bldg P-140 at New Mil Stn Kapurthala under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises. |
| 3 | M&L for glazed ceramic coloured tiles in vertical surfaces 450X300X 7mm thick over 10 mm thick rendering in cement mortar (1:4) as in vertical surfaces such as in dado/skirting including set and jointed neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed. |
| 4 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but n.exc 0.11 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed 1:6 complete all as specified and directed. |
| 5 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed. |
| 6 | Demolition of brick/block masonry built in cement mortar including all quoins, arches, pillars etc and clearing off the premises complete all as specified and directed. |
| 7 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 8 | Taking down cement plaster on brick work or concrete surfaces incl racking out joints all as specified. |
| 9 | M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified. |
| 10 | M&L for 15mm thick Rendering in cement mortar 1:4 on brick work or concrete surfaces with water proofing compound finished even and smooth etc; complete all as specified and directed. |
| 11 | M&L for 5mm thick rendering in cement mortar 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in ceiling etc; complete all as specified and directed. |
| 12 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distermper complete all as specified and directed. |
| 13 | M&L for preparation of plastered and unplastered surfaces of wall and applying two coats of oil bound distemper over 3mm wall care putty complete all as spedifed and directed.Note:- OBD to be done by Roller. |
| 14 | M&L for applying two coats of exterior emulsion paint on plastered or unplastered wall surface including preparation of surfaces, complete all as specified and as directed. |
| 15 | M&L for applying two coats of exterior emulsion paint on old plastered or unplastered wall surface including preparation of surfaces, complete all as specified and as directed. |
| 16 | Demolition of cement concrete of any description and in any position not otherwise specially provided for. |
| 17 | M&L for water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WC's etc; shall be as under:- |
| 18 | (i) Application of Two component acrylic modified cementitious coating.(a) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement litance, existing coatings and achieve a gripping profile that is clean, dry and free from litanceand any other form of surface contamination. the installation instructions in manufacturer's published literature should be strictly compiled with, including but not limited to the following:-(b) Chipping out any visible cracks in ' V- Groove' pattern as applicable. Special attention on this part cleaning of cracks and then filling those cracks with SIKA latex SBR 100 putyy/ Dr Fixit 302 SBR latex/ perma latex SBR / FOSROC Nitibond SBR latex/ Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush and vaccum pressure if required.(c) Dampen all surfaces immediately ahead of application of Acrylic modified cemetitious coating of Sika Top seal - 107/brush Bond FOSROC/ Dr Fixit/ STP/ CICO.(d) While the surface is still damp from saturation (SSD), apply one coat of acrylic modified cementitious coating of Sika Top seal- 107/ Brush bond FOSROC/ Dr fixit / STP/ CICO of viscosity as per manufacturer's instructions.(e) Apply glass fabric sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP while the first coat is wet.(f) Once touch dry apply second coat of Acrylic modified cementitious coating of Sika Top Seal- 107/ Brush bond FOSROC/ Dr FiXit/ STP/ CICO of viscosity as per manufacturer's instructions on the entire area.(g) Second coat shall be applied after 6-8 hrs of application of previous coat and in the direction right angle to the previous coat.(h) The waterproofing coating should be taken to a height minimu 300mm above the finished floor level on the vertical surface.(j) It is essential to cure acrylic modified cementitious coating immediately after application ( minimum 6-8 hrs drying) for a minimum of 3 to 54 days to ensure full cement hydration and to minimize cracking. |
| 19 | (k) A protection plaster ( 12-15 mm thick) in cement mortar 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls.(l) Providing and applying a protection screed of 50 mm thick 1:4 cement sand mortar admixed with Sika plastocrtete over the applied water proofing coating on horizontal surfaces.Admixutre for item( k&l) above : Sika Plastocrete Plus/ FOSROC/ Dr Fixit/ STP/ CICO confirming to IS 2645(m) All the corners and joints should be pretreated with elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of make Sika Seal Tape S/FOSROC/Dr Fixit/STP.(n) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations.(o) waterproofing treatment has to be carried out through applicators authorised.(ii) All the joints of pipesand traps within sunken portion shall be selaed properly by Epoxy sealant.(iii) All CI traps in sunken slabs to be enclosed with PCC 1:1.5:3 (min 15cm) all - round.(iv) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40 mm stone aggregate) complete all as specified.(v) Providing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall ( Approx 450mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed.(vi) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5 mm grade stone aggregate as in flooring for laying floor finish all as specified.Note:- Item (iv), (v) & (vi) above shall be measured and paid seprately. |
| 20 | M&L for providing GI pipe heavy class of dia 40mm all as specified and directed. |
| 21 | M&L for PCC (1:5:10) type E2 using 40mm graded aggregate thick as in sub base complete all as specified and directed. |
| 22 | M&L for PCC type B-0 (1:2:4) (12.5mm stone graded aggregate), 40 mm thick as for receiving top finishing layer of ceramic tiles for sunken portion finished even and smooth etc; complete all as specified and directed. |
| 23 | M&L for 75mm thick PCC 1:3:6 type C2 as in plinth protection finishing the surface even and smooth with out using extra cement complete all as specified and directed. |
| 24 | Demolition of cement concrete (reinforced) of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work(reinforcement cut as required to facilitate demolition) all as specified and directed. |
| 25 | Removing of debris material and depositing it out side the defencde land all as specified and directed. |
| 26 | M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick plaster on fair faces or other than fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement all as specified and directed. |
| 28 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 29 | M&L for dugging out average 10mm thick on distubed chajja beam, slab portion, parapet and applying chicken wire mesh over disturbed portion fixed with drilling, bolting etc after anti corrosion treatement of steel bar and finally finished with 10mm thick (1:3) cement plaster mixed with WPC @3% by the weight of cement all as specified and directed by Eng-in-Charge.Note:- (a) The bars which are corroded badly needs to be strengthen by placing new bars by means of proper splicing and will be measured and paid seprately under appropriate item.(b) RCC 1:2:4 type B-0 to be measured and paid seprately(ii) The rate of item includes necessary shuttering, scaffholding, staging etc all as specified and directed by Eng-in-Charge. |
| 30 | Use and waste of formwork to chajjas and similar items including edges rough finished complete all as specified and directed. |
| 31 | M&L for TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending hooking etc & binding with mild steel binding steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 32 | M&L for RCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in chajjas etc. complete all as specified and directed. |
| 33 | Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area not exc 1.50 sqm each |
| 34 | Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area exc 1.50 sqm but n.exc. 4sqm each. |
| 35 | S&F of solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and directed. |
| 36 | S&F of factory made solid panel PVC moulded door shutter, 30mm thick (style) consisiting of frame made out of MS tubes for top and bottom rails. M.S. frame shall covered with heat moulded plain colour PVC \\"C\\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail, bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing including fittings |
| 37 | S&F for factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows & other frames/chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners including in this item). Note:- For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 38 | S&F of factory made single 30 mm thick extruded WPC (Wood Polymer Composite) solid moulded flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.Note:- stainless steel butt hinges and necessary S S screws incl in this item |
| 39 | S&F of 35 mm thick Factory Made 100% Solid WPC (Wood polymer Composite) Glazed and skeleton Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), alcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm manufactured and an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws as per required. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company.Note:- stainless steel, butt hinges,luminum Jali and Stainless wiremess and necessary S S screws incl in this item |
| 40 | S&F of alumunium hinges for PVC door shutter, size of hinges in 100mm |
| 41 | S&F of Aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt in 150mm |
| 42 | S&F of extruded aluminium alloys handles frabicated type anodized of size 150mm long. |
| 43 | S&F of aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 250mm complete all as specified and directed. |
| 44 | S&F of steel window 1.25mm thick box type ( primer coated) ERW hollow 'P' section of size 60mm x 25mm single rebated comprises glazed Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter:-(a) Mild steel hold fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note:- (i) Glass and painting shall be measured and paid separately under appropriate item (ii) Irrespective of whatever shown on drgs, MS gills shall be of 12mm dia MS square bar and paid separately under appropriate item. |
| 45 | S&F of steel window 1.25mm thick Box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter:-(a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf.Note:- Wire mesh and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed. |
| 46 | M&L for framed work such as grills gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framed work of water tanks and similar work as specified and directed. |
| 47 | M&L for ventilators fixed type of 50x20mm hollow pipe of 1mm thick with glazing bars etc; complete all as specified and directed. |
| 48 | S&F of 4.00mm thick plain glass, pinhead type in squares n.exc 0.5 sqm each pane and glazing with oil putty all as specified. |
| 49 | S&F of 4.00mm thick figured glass, pinhead type in squares n exc 0.5 sqm each pane and glazing with oil putty all as specified. |
| 50 | S&F in repairs for stainless steel wire cloth 0.56mm nominal dia of wire and avarage width of aperture 1.00mm and fixed with tinned tacks/screws with bolts inclding leaping wooden. |
| 51 | S&F in repairs of size 300mm MS ordinary rat rail rod pattern helical springs including roller and roller plate complete all as speicified |
| 52 | Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete all as directed. |
| 53 | S&F of CPVC pipes outer dia of 16mm, SDR 11 & plain CPVC SDR 11 fittings complete all as specified and directed. |
| 54 | Taking down GI tubing and connection 25mm dia laid in floor / trenches or fixed to walls complete all as directed. |
| 55 | S&F of CPVC pipes outer dia of 25mm, SDR 11 & plain CPVC SDR 11 fittings complete all as specified and directed. |
| 56 | S&F in repairs 15 mm bore CP bib taps cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete. |
| 57 | S&F in repairs 15mm dia stop valve/angle valve, CP cast copper alloy with crutch or butterfly handle, screwed down high pressure, screwed both ends for iron pipe and fixed complete all as directed |
| 58 | S&F of vitreous china squatting pan orissa pattern wash down water closet of size 580x440 mm, white, with integral foot rests complete fixed in repairs with P or S trap, PVC flushing cistern low level of Make 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc; complete. |
| 59 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern) \\"with plastic closet seat cover closed pattern with flat bottom and cover and mild steel chromium plated hinging divice including flusing cistern and flush pipe in repairs complete all as specified and directed. |
| 60 | S&F in repairs CP Jet for EWC including flexible pipe complete all as specified and directed. |
| 61 | S&F in repairs hand shower/ health fauset (Chromium Plated) with 8mm dia, 1 metre long flaxible tube & wall hook complete all as specified and directed. |
| 62 | S&F of CP glass corner shelf including CP railing, radius 300mm fixed in repairs complete all as specified and directed. |
| 63 | S&F of 600x450 mm size and 5.5mm thick looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel alround,mounted on 6 mm thick commercial ply or AC building board, fitted to wooden plug with CP screws complete all as specified and directed. |
| 64 | S&F of 20mm dia brass chromium plated tubular towel rails,D type,60cm long between flanges, complete all as specified and directed. |
| 65 | S&F in repairs PVC(SWR) floor trap with grating and diameter of outlet 75mm including jointing with solventcomplete all as specified and directed. |
| 66 | S&F in repairs fancy type chromium plated stop valves with long shank and cup (concealed type) cast copper alloy screweddown high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore fof size 15mm complete all as specified and directed. |
| 67 | S&F of vitreous china ware wash basin white, flat back size 550 X 400mm including 15mm dia pillar tap chromium plated, CP waste coupling, waste fittings, union and waste pipe 32mm dia or required length and all necessary inlet, out let connections complete all as specified and directed. |
| 68 | S&F in repairs shower rose size 100mm with CP arm of chromium plated any colour or fixing with 15mm pipe (minimum weight 40gm) complete all as specified and directed. |
| 69 | Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs as directed. |
| 70 | Demolition of mud in roof any thickness including plastering & leeping removed as directed. |
| 71 | M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with waterproofing compound as directed. |
| 72 | Supply only integral water proofing compound. |
| 73 | Preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) |
| 74 | M&L for 40 mm thick Cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in PCC padding over roof slab complete all complete all as specified and as directed. |
| 75 | M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:3 with jointing and pointing in cement mortar (1:3) mixed with 5% crude oil by weight of complete all as specified and directed. |
| 76 | - ditto - all as per item No 73 above but except brick tiles including cleaning from mortar complete all as specified and directed. |
| 77 | M&L for cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs, rounded or chamfered edges complete all as specified and directed. |
| 78 | Cutting chases pinning in brick/stone/blocks masonary in making good to facings where required and pointing in cement mortar (1:3) to ends or eges of steps, cills, sun shades, shelves, lintel etc and cutting chases for concealed water tubing or etc and making good, |
| 79 | S&F of vitreous china urinals bowl type of size 465 x 355 x 265mm (flat back or corner wall type) complete including providing & fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with & including 60cm long brass screws, jointing around urinal back in cement paste including flush pipe, grating and union for discharge pipe as specified. |
| 80 | S&F of urinal spreader of PTMT any colour for fixing with 15mm dia pipe incl PVC connection length of 450mm |
| 81 | Dismantling of cast iron pipe any diameter jointed with cement mortar or lead incl all fittings from wall or floors as specified and directed. |
| 82 | S&F of 75 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as directed. |
| 83 | S&F of 75 mm PVC (SWR) pipes in repair single socketed in any length laid in floor complete all as directed. |
| 84 | S&F of 75 mm PVC (SWR) bend complete all as directed. |
| 85 | S&F of 75 PVC (SWR) junction single, (single T) equal or unequal complete all as directed. |
| 86 | S&F of 110 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as directed. |
| 87 | S&F of 110 mm PVC (SWR) bend with complete all as directed. |
| 88 | S&F of 110 PVC (SWR) junction single, (single T) equal or unequal complete all as directed. |
| 89 | S&F of 110mm PVC vent cowl. |
| 90 | Dismantiling water tank PVC 1000 Ltrs and removing from site |
| 91 | S&F of rotational moulded polythelene water storage tanks 1000ltrs capacity with threaded lid white colour hoisted and fixed in postion incl fittings and as directed. |
| 92 | S&F of gunmetal globe and gate valve with iron welded hand secrewed both and for iron pipe 25mm fixed in repairs complete all as specified and directed. |
| 93 | S&F of ball valves high pressure of PTMT with epoxy coated aluminium rod and high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms) |
| 94 | S&F and erection of structure for 03 mm thick Aluminium composite panel (.25 mm coil thick ) cladding made of aluminium chanel (25x50x1.6mm), for walls , columns, facias, cornices including necessary hardware with backup material and weather sealent to make joint leak proof and S&F of 03mm thick PVDF coating Aluminium composite panel complete all as per specified. Spacing of channel to be min 05 cm or as per direction of Eng in Charge. |
| 95 | Excavation in trenches n.exc 1.5m deep & n.exc1.5m wide on plan in soft/loose soil and getting out. |
| 96 | M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified. |
| 97 | Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil. |
| 98 | Removing excavated material n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 99 | M&L for providing precast cement concrete 1:2:4 as in man hole covers type B-1 (20 mm graded agg) as in manhole cover set in cement mortar 1:6 , including necessary form work complete all as specified and directed by the Engineer in Charge. |
| 100 | M&L for concrete bed to drain pipes 300mm bore in cement concrete (1:3:6) type D-2 (using 20mm graded stone aggregate) including forming cradels with concrete after they are laid and tested complete all as specified and directed |
| 101 | M&L for RCC 300mm bore class NP2 laid and jointed complete with collars laid in trenches and tested complete all as specified and directed |
| 102 | M&L for cement concrete in 1:2:4 type B0 (12.5mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 103 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit or to refixing of serviceable items(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 104 | M&L for point wiring with 1.5 Sqmm (Nominal Area) FRLSH PVC insulated sheathed multi stranded copper conductor, 1100 Volts drawn through and including rigid non metalic concealed conduit medium grade ISI marked minimum 20mm size and its accessories complete along with 1.5 sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed, in walls/ ceiling/ roofs with and including 1.2mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting modular switches, socket, bell push, fan regulators etc. as required with modular frame and cover of 1 module to 18 module as required at site all as specified and as directed for the following points :- |
| 105 | One light point controlled by one 1-way switch. |
| 106 | One ceiling / exhaust fan point controlled by one switch. |
| 107 | One three pin socket out let 5 amps on independent board complete. |
| 108 | - ditto - all as per item No 102 above but with 2.5 Sqmm (Nominal Area) FRLS PVC insulated sheathed multi stranded copper conductor, 1100 Volts for one 3 pin socket out let 15 amps on independent board. |
| 109 | - ditto - all as per item No 102 above but with 4 Sqmm (Nominal Area) FRLS PVC insulated sheathed multi stranded copper conductor, 1100 Volts for one geyser point on independent board. |
| 110 | S&F of switch modular type 6A 240 Volts complete all as directed |
| 111 | S&F of switch modular type 15A 240 Volts complete all as directed |
| 112 | S&F of ceiling rose surface type Bakelite 65 x 50 mm with three terminals complete all as directed |
| 113 | S&F of socket outlet 2 in 1, 3 pin, 5/6 amp modular 2 module type with shutters complete. |
| 114 | S&F of socket outlet 2 in 1, 3 pin, 5 and 15 amp modular type 2-module shutters complete. |
| 115 | Taking down ceiling fen and cable end, dismantling blades and removing fan and each blades to E/M store yard complete all as directed |
| 116 | S&F of exhaust fan copper wound, double ball bearing, metallic heavy duty exhaust fan continuous duty with louvers and shutters, with fixing arrangements & making hole of suitable size if necessory for 300 mm sweep, 1400 rpm, 240V. |
| 117 | S&F of LED light fitting 1x20 watt, 220 volt AC aluminium housing box type with driver, holders,including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed. |
| 118 | S&F of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders,including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed. |
| 119 | M&L for sub main wiring with FRLS PVC insulated. 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications with 4 runs of 6 sqmm single core multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor drawn through & including PVC conduit of 20mm dia. size and conduit accessories concealed in wall connecting to common earth dolly all as specified and directed. |
| 120 | S&F of TPN horizontal type, 4 way, 415 Volts, 50 Hz, indoor type double door sheet metal enclosure IP-54 DB's IK-09 flush mounted with 200 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable management including Provision of MCB 100 Amps, four pole as incomer including connecting terminal strip complete and SP MCBs as out going etc complete pre wired with suitable size copper conductor complete all as specified and directed by Eng-in-charge. |
| 121 | S&F of MCB TPN 240 volts 25- 100 Amps, 16KA, B-series. |
| 122 | S&F of MCB Single pole 240 volts 6-32 Amps, 10KA, B-series, |
| 123 | S&F of MCB SPN 240 volts 0- 32 Amps, 10KA, B-series. |
| 124 | M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed. |
| 125 | S&F of electric water heater, storage type steel body with mettalic inner tank and 3KW heating element capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, Automatic Thermal cut-out and multi function valves, NRV, Steel braided 450 mm connection pipe etc; complete all as specified and directed. |
| 126 | S&F of SPN enclosure with a two pin and earth plug and socket with single pole MCB 20 Amp complete all as specified and directed. |
| 127 | Supplying, laying, testing & commissioning of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 16 Sqmm of conductors with thimbles complete all as specified and directed. |
| 128 | M&L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed.Note:- Excavation and earth work measured separately). Note- Punned down thickness shall be measured and complete all as specified and directed |
| 129 | Supplying and laying brick common burnt sub class 'B' old size and for protection of cable laid in trenches for underground cable of compressive strength not less 75 Kg/Sqcm all as specified and directed |
| 130 | M&L for GI steel tubing medium grade of 50 mm dia for cable protection, passing under road/floor or for fixing to poles/walls all as specified and directed for the following sizes. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender