Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #57179942

Tender For Construction Of Technical Building Under Ge 862 Ews

Issued by Statutory Bodies & Commissions/Committees · Rajouri, Jammu and Kashmir
Tender Value
6.51 Crore
Estimated cost
Bid Submission
28 Sep 2026
25 days left
EMD
6.50 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Technical Building Under Ge 862 Ews

BOQ

Name of Work:- CONSTRUCTION OF TECHNICAL BUILDING UNDER GE 862 EWS
Sl. No. Item Description
1Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
2Construction of block of Technical building (1x IGLOO 200 MT NEC at AP-252, Rajouri (25INF DOU) complete all as specified and as shown on drawings.Note: The building work is deemed to include VIFT, side wall, toe wall with saucer drain, earth traverse etc; alongwith all other details as shown on drawings (including bringing of approved soil as required to be brought from out side MD land). In this connection, please refer Sch 'A' Note No. 6 (b) here-in-before.
3Total Amount of Sch 'A' Part - II (Site Clearance and Development Work)
4Total Amount of Sch 'A' Part -III (Area Drainage)
5Total Amount of Sch 'A' Part -IV (Road, Culvert and Sign Board Work)
6Total Amount of Sch 'A' Part - V (Sec-I) (Protective Work)
7Sch 'A' Part - V Sec-II (Protective Work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
840mm graded crushed stone aggregate hand packing tightly in wire crating apron bounds, (any thickness) at back side of weep holes and raising or lowering to the required level complete all as specified.
9Welded steel wire fabric weight not exceeding 4kg/sqm made uo into wire mesh create (size of each create 500mm x 500mm x 500mm) complete all as specified.
10Total Amount of Sch 'A' Part - VI (Lightening Arrestor Work)
11Total Amount of Sch 'A' Part - VII (Demilition/Dismantling)
12Total Amount of Sch 'A' Part - VIII (External Electric Supply Work)
13Sch 'A' Part IX (Internal Electrification Work and Misc Items of Work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
14Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to copper earth strip of size (20x3)mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron or steel with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. (Contd.../)
15Note: - (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge.
16Earthing complete with steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm dia (SWG) as earthing lead by means of volts, nuts, check nuts and washer of GI or steel , protected GI pipe medium grade 15mm dia for protection of GI earth wire and 20mm dia GI pipe medium grade for watering with alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. (Contd...)
17Note:- (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge.
18Double walled corrugated (DWC HDPE) pipe of size 75mm including snap fit coupler conforming to IS16205 (Pt-II)/IS 61386 Pt-II for protection of under ground cable complete all as specified and directed.
19Fire Alarm sounders/Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5 db 500m range complete all as specified and directed.
20Concealed point wiring for one light/fan/bell point controlled by one flame proof switch 6/ 5 Amp one way single pole complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including steel mettalic Conduit 20mm dia medium grade with MS conduit accessories and duly concealed in walls / roofs / floors / ceiling etc; including modular metal flush box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm ,1100volt grade PVC insulated multistranded FRLSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Contd...)
21Note No1: All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used of same make/brand only. Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes.
22Concealed point wiring for one light/fan/bell point controlled by one flame proof switch 16/15 Amp one way single pole complete with 2.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including steel mettalic Conduit 20mm dia medium grade with MS conduit accessories and duly concealed in walls / roofs / floors / ceiling etc; including modular metal flush box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved colours and including 2.5 Sqmm ,1100volt grade PVC insulated multistranded FRLSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Contd.../)
23Note No1: All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used of same make/brand only. Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes.
24Flame proof sub main wiring with two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and including concealed rigid steel conduit medium grade ISI marked 20mm dia or above required including one single core in surface/recessed, FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth dolly complete all as specified and directed.Note No. 1: Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of steel conduit shall be measured as one unit only.Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes.
25Switch flame proof rotatory type with termination box in LM6, 16Amp, single pole 250V, complete all as specified and directed.
26Switch flame switch socket and plug combined in LM6 cable termination box in LM6, 16Amp, 250V, complete all as specified and directed.
27LED light fitting 1x16 watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc; complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed.
28Flame prrof suitable for hazardous area laden with gaes /vapour of Group II(A) and II(B) as per IS 2148/1984, made out of cast aluminium alloy LM6 having for flush/surface mounting distribution board, factory made, protection class IP 55 suitable for mounting MCBs, SPN 8 way,240 volts with 200 amps tinned copper bus bar, cable lugs,earthing,neutral terminal , complete all specified and directed.
29Flame proof, MCB, single pole & neutral, 240 volt, 10KA, 'C' curve, 40 amp to 63 amp.
30Flame proof, MCB, single pole & neutral, 240 volt, 10KA, 'C' curve, 6 amp to 40 amp.
31Deduction to be made from BOQ for Sch 'A' Part -XV (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57179942
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6.51 Crore
LAST DATE 28-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Construction Of Technical Building Under Ge 862 Ews
Basic Detail
Tender No 87995-A/E8
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 24 Aug 2026
Submission Date 28 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 6.51 Crore
Tender Fee 3000
EMD 6.50 Lakhs
Exemption Available
Document List
baf5e0e6-82c9-4cb4-8b0a-a583911cd24c.html
BOQ_880817.xls
Drg1.pdf
Drg2.pdf
Drg3.pdf
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

baf5e0e6-82c9-4cb4-8b0a-a583911cd24c.html

xls

BOQ_880817.xls

pdf

Drg1.pdf

pdf

Drg2.pdf

pdf

Drg3.pdf

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders