Tender For Repair/ Maintenance Of Summer Appliances Including Precision Ac At Nad, maintenance of Goa Under Ge Gomantak Vasco
Tender Value
30 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
4 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Summer Appliances Including Precision Ac At Nad, maintenance of Goa Under Ge Gomantak Vasco
BOQ
| Sl. No. | Item Description |
| 1 | Material and Labour for servicing of following appliances comprising of thorough cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc. to make the unit for smooth operation for the following capacity of water cooler / refrigerator/Deep freezer :- (a) Water coolers 40 to 150 ltrs cooling capacity. |
| 2 | (b) Refrigerator of any capacity. |
| 3 | (c) Deep Freezers upto 425 ltrs capacity |
| 4 | Supply and charging refrigerant gas F-12/R-134 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any Make Paragon, Mefron complete all as specified and directed for the following capacity of water cooler / refrigerator/Deep freezer :- (a) Water cooler of 40 to 150 ltrs capacity. |
| 5 | (b) Refrigerator of any capacity |
| 6 | (c) Deep freezer of upto 425 ltrs capacity |
| 7 | Supply and replace compressor sealed unit of the following appliances of any make mentioned below complete including replacement of copper tubing/capillary strainer etc., testing and commissioning all as specified and as directed for the following capacity of water cooler / refrigerator/Deep freezer :- Make :Emerson, Kirloskar, Voltas(a) Water coolers of 40 to 150 ltrs capacity |
| 8 | (b) Refrigerators of any capacity . |
| 9 | (c) Deep freezers of upto 425 ltrs capacity. |
| 10 | Supply and replace starting relay as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity |
| 11 | (b) Refrigerator of any capacity. |
| 12 | (c) Deep freezers of upto 425 ltrs capacity. |
| 13 | Supply and replace thermostats as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity |
| 14 | (b) Refrigerator of any capacity. |
| 15 | (c) Deep freezers of upto 425 ltrs capacity. |
| 16 | Supply and replace condenser unit including making of all connections as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity |
| 17 | (b) Refrigerator of 165 to 340 ltrs capacity. |
| 18 | (c) Deep freezers of upto 425 ltrs capacity. |
| 19 | Supply and replace cooling coil as per existing suitable for the following capacity of water cooler / refrigerator:- (a) Water coolers of 40 to 150 ltrs capacity. |
| 20 | (b) Refrigerator of any capacity. |
| 21 | Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity. |
| 22 | Supply and replace overload protector of the following :-(a) Water coolers/ Refrigarator upto 340 ltrs cooling capacity. |
| 23 | (b) Deep freezers of upto 425 ltrs capacity. |
| 24 | Supply and replace ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule of the following sizes :- (a) 15mm dia |
| 25 | (b) 20mm dia |
| 26 | Supply and fix PVC insulated and overall PVC sheathed circular flexible 3 core 4 Sqmm copper conductor cable including disconnecting and removal of old cable complete all as directed. |
| 27 | Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames as per existing suitable for the following capacity of water cooler / Deep freezer:- (a) Water coolers of any make and cap 40 to 150 ltrs. |
| 28 | (b) Deep freezer of any make and capacity upto 425 ltrs |
| 29 | Dismantling and removing of defective burnt motor from unit and rewinding the motor with super enamel copper winding wire including replacement of worn out motor bearing, refixing and testing as per existing suitable for the following capacity of water cooler / Deep freezer:- (a) Water coolers of any make and cap 40 to 150 ltrs. |
| 30 | (b) Deep freezer of any make and capacity upto 425 ltrs |
| 31 | M&L for servicing of following appliances comprising of thorough cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-(Note : Above second floor contractor will arrange crane / scaffolding with safety device)(a) Window type AC of capacity 1.5 Ton cap. |
| 32 | (b) Split type AC 1.5/2 Ton capacity. |
| 33 | Supply and charging refrigerant gas R-22/R-32 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed.Make Paragon, Mefron (Note: Above second floor contractor will arrange crain / scaffolding with safety device)(a) Window type AC of capacity 1.5 Ton. |
| 34 | (b) Split type AC 1.5/2.0 Ton capacity |
| 35 | Supply and replace compressor sealed unit of the following appliances complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed. (Note : Above second floor contractor will arrange crane / scaffolding with safety device)Make : Emerson, Kirloskar, LG(a) Window type AC of capacity 1.5 Ton. |
| 36 | (b) Split type AC 1.5/2.0 Ton capacity. |
| 37 | Supply and replace capacitors of the following capacities for ACs Make : Siemens, Epcos/Universal(a) 4/6 micro farad |
| 38 | (b) 10 micro farad |
| 39 | (c) 36 +4 micro farad (Six Pin) |
| 40 | (d) 50 micro farad |
| 41 | (e) 45+6 micro farad Seven Pin |
| 42 | Supply and replace starting relay suitable for :-(a) Window type AC of capacity 1/1.5 Ton cap. |
| 43 | (b) Split type AC 1.5/2 Ton capacity |
| 44 | Supply and replace thermostats of :- Make: Danfoss, Annapurna(a) Window type AC of capacity 1/1.5 Ton cap. |
| 45 | (b) Split type AC 1.5/2 Ton capacity. |
| 46 | Supply and replace overload protector of :- Make Usha, Annapurna(a) Window type AC of capacity 1/1.5 Ton. |
| 47 | (b) Split type AC 1.5/2 Ton capacity. |
| 48 | Supply and replace condenser unit made of copper of the following appliances including making of all connections as specified and directed.Make :.LG, Voltas, Whirpool(a) Window type AC of capacity 1/1.5 Ton capacity. |
| 49 | (b) Split type AC 1.5/2 Ton capacity. |
| 50 | Supply and replace of evaporator coil of :-(a) Window type AC of capacity 1/1.5 Ton cap. |
| 51 | (b) Split type AC 1.5/2 Ton capacity. |
| 52 | S&F in replacement sheet metal enclosures, single pole with socket, plug top and one single pole MCB 20 Amps, 240 V complete all as specified and directed. |
| 53 | S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 54 | Supply and replace contact unit of split type AC 1.5/2 Ton capacity. |
| 55 | Supply and replace internal wiring complete suitable for :-(a) Window type AC of capacity 1/1.5 Ton. |
| 56 | (b) Split type AC of any make and capacity 1.5/2ton. |
| 57 | Dismantling and removing of defective burnt motor from unit and rewinding the motor with enamel copper winding wire incl replacement of worn - out motor bearing, refixing and testing all as directed for the following :-(a) Window type AC of any make and capacity 1/1.5 Ton. |
| 58 | (b) Split type AC of any make and capacity 1.5/2 ton. |
| 59 | Supply and replace blower/condenser fan motor complete with necessary mounting bracket and base frames for :- Make Crompton Greaves, Voltas, LG.(a) Window type AC of any make capacity 1/1.5 Ton. |
| 60 | (b) Split type AC of any make and capacity 1.5/2 ton. |
| 61 | Supply and fix Air filter suitable for 1.5/2.0 ton split type AC of any make all as directed. |
| 62 | Supply and fix insulation for copper tubes of split type AC units, insulation type superlon of size 3/8\\" diameter all as directed. |
| 63 | Supply and fix insulation for copper tubes of split type AC units, insulation type superlon of size 5/8\\" diameter all as directed. |
| 64 | Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8\\" diameter all as directed. |
| 65 | Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8\\" diameter all as directed. |
| 66 | Supply and fix in repair PCB (Printed circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC indoor unit all as directed. Make: LG, Voltas, Daikin |
| 67 | Supply and fix in repair PCB (Printed circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC out door unit all as directed. Make: LG, Voltas, Daikin |
| 68 | Supply and fix in repair PCB(Printed circuit board) complete suitable for 1.5/2.0 ton capacity non Inverter type split AC out door unit all as directed. Make: LG, Voltas, Daikin |
| 69 | Supply and fix in repair indoor cooling unit with rotary fan suitable for 1.5 ton Split AC all as directed.Make: LG, Voltas, Daikin |
| 70 | Supply and fix in repair indoor cooling unit with rotary fan suitable for 2 ton Split AC all as directed.Make: LG, Voltas, Daikin |
| 71 | Supply and fix in repair outdoor unit with rotary fan suitable for 1.5 ton Split AC all as directed.Make LG, Voltas, Daikin |
| 72 | Supply and fix in repair outdoor unit with rotary fan suitable for 2 ton Split AC all as directed.Make LG, Voltas, Daikin |
| 73 | Supply of remote control as per existing make of any size and capacity of split AC all as directed. |
| 74 | Supply and fix in repair Voltage stabilizer Capacity of 5 KVA of range 130 V to 180 V suitable for up to 2 Ton split AC. Make: V-Guard/MicroTek/Luminous. |
| 75 | Taking down of Split type AC (Indoor & out door with mounting bracket & voltage stabilizer) of any capacity from existing place and Reinstalling the same in another location complete and testing & commisioning all as specified and directedNote : New spares required for replacing (mounting bracket, insulation for copper and copper tubing) shall be measured and paid seperately. |
| 76 | Supply and replace 3 Pin Plug Top of 16 A , 240 volts all as directed.Make : Havells/ Anchor |
| 77 | Supply and replace of Heating element of cold room door as directed and specified. |
| 78 | Supply and replace of Thermostat of cold room door heater as directed and specified. |
| 79 | Supply and replace of metal clad 3 pin plug top 20 A, 240 Volts suitable for sheet metal encoluser complete as directed and specified.Make : Havells/ Anchor |
| 80 | Supply and replace of metal clad 3 pin socket 20 A, 240 Volts suitable for sheet metal encoluser complete as directed and specified.Make : Havells/ Anchor |
| 81 | S&F in repair PCO5+ suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site |
| 82 | S&F in repair PGD1 display suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site |
| 83 | &F in repair expansion board suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site |
| 84 | S&F in repair tLAN Card suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site |
| 85 | S&F in repair Pressure Transducer suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site |
| 86 | S&F in repair NTC Sensor suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site |
| 87 | S&F in repair CT suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site |
| 88 | S&F in repair Power supply (SMPS) suitable for PRECISION AC complete all as specified and directed. |
| 89 | Charges for Mechanic Net-working Programming for PRECISION AC complete all as specified and directed. |
| 90 | S&F in repair Retrofitting suitable for PRECISION AC complete all as specified and directed. |
| 91 | S&F in repair 7HT Temp Sensor suitable for PRECISION AC complete all as specified and directed.NOTE FOR ITEM NO. 81 to 91 :- Work will be executed through authorised person of company. In this regard necessary certificate along with bill of authorised service partner of company will be submitted by contractor before payment. |
| 92 | Supply and installing electrical cold room panel, three phase supply, 415 Volts, AC supply showing display temperature, voltage, current and humidity complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender