Tender For Special Repair/Replacement Of Ceiling Fans, Geyser And Exhaust Fans At Various Location And special Rep Of Street Light At 15% Defence Civilian Colony And Key Personnel Colony And special Rep Of Boundary Security Light And Connected Access
Tender Overview
Project Description
Tender for Special Repair/Replacement Of Ceiling Fans, Geyser And Exhaust Fans At Various Location And special Rep Of Street Light At 15% Defence Civilian Colony And Key Personnel Colony And special Rep Of Boundary Security Light And Connected Accessories At Det Malad (Ex-Cod Mumbai) Under Ge (North) Santacruz
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Aug-2026 | BOQ Corrigendum | BOQ | 14-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, lay, test and commissioning of LT UG cable of size 10 sqmm 4 core, XLPE insulated, heavy duty, 1100V grade (Earthed) electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and as directed |
| 2 | Supply and fixing of LED street light fitting 60 watts, rating, separate individual peanut plated lens and aluminium reflector housing made of LM6 pressure die cast aluminium. Optical cover toughened glass only, impact resistance>IK05 IP protection not less than IP66, protection should be class I vibration as per IEC 60598, product standard IS 10322/IEC60598, all the component such as driver, surge protector should be of same make. Driver should be moulded type with operating voltage 140V-270V, driver frequency 50 Hz power factor >0.9, Lumen output should not be less than 130 lumen/watt and luminaries driver ckt, moulded type weather proof construction with separate surge protection device 5 KA rating and separate connector block for termination of incoming cable connection all as specified and directed by Engineer-in-Charge. Make - Crompton Cat part No - LSTP-90-CDL-M or Equivalent of Osram / Philips / General electric (GE) |
| 3 | Supply and erect 7 meter long hot dipped galvanised OCTAGONAL street light pole with two light bracket for street light. The bottom of pole shall be 130mm dia and top shall be 70mm dia with 3mm thickness, high tensile strength conforming to BS EN 10025, base plate shall be 220x220x112mm with 4 nos of anchor bolt 'J' type 700 mm long 20mm dia with nut washer and bolt shall be inserted to RCC footing. The pole shall have internal inbuilt junction box including 3 phase bus bar and one 6 Amp MCB complete including necessary earthwork excavation in hard/dense soil, RCC M-20 concrete footing with reinforcement, as per manufacturer drawing formwork etc complete all as specified and directed. |
| 4 | Supply and laying 3 core PVC insulated and unsheathed 1100 volt grade multicore cable 1.5 sqmm with stranded copper conductor cable drawn inside pole whereas required on bottom and top of pole from looping box inside to security light fitting etc, complete all as specified and as directed by Engr-in-charge. |
| 5 | Supply and laying DOUBLE WALLED CORRUGATED (DWC) HDPE pipe 40mm bore, TELEREX 450N as per IS-16205 and including couplers and bend for cable protection laid in trenches complete all as specified and directed. |
| 6 | Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for foundation or pole or laying of cable and getting out in soft/ loose soil complete all as specified and directed |
| 7 | Returning filling in, using excavated soil including spreading, leveling, watering and well ramming of soft soil in layers not exc 25cm complete all as specified and directed |
| 8 | Removing excavated surplus material / debris n.exc 50m and depositing where directed at a level n. exc 1.5 above the starting point all as specified and directed |
| 9 | Excavation in trenches not exc 1.5m in depth and not exc 1.5m wide for laying UG cables and getting out in hard /dense soil complete all as specified. |
| 10 | Returning, filling in, including spreading, levelling watering and well ramming of hard and dense soil in layers not exc 25 cm. |
| 11 | Supply, lay, test and commissioning of LT UG cable of size 10 sqmm 2 core, XLPE insulated, heavy duty, 1100V grade (Earthed) electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and as directed |
| 12 | Supply and fixing as in repair 1100 volts grade heavy duty cables PVC insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection of one twin core cable flat or circular, stranded aluminium conductor of size 6 sqmm 2 Core fixed on wall by means of saddle, nut and bolts complete all as specified and directed. |
| 13 | Supply and lay in repair GI pipe medium grade 40mm bore for cable protection/ for post top lantern laid in trenches/ foundation complete all as specified and directed. |
| 14 | M&L for cutting or cutting the existing Bitumen road / hard standing to size not exceeding 45 cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1;3;6 type C1 using 20mm graded aggregate complete all as specified and directed. |
| 15 | S&F LED street light fittings minimum 70 watt rating separate individual peanut plated Lens and aluminium reflectors housing should be made of LM6 Pressure dia cast aluminium.Optical Cover should be only, Toughened Glass only Impact resistance > IK05 IP Protection not less Than IP -65, Protection should be class I Vibration should be as per IEC-60598, Product standard IS 10322/IEC 60598, all the component such as driver, surge protector should be of same make. Driver should be moulded type with operating voltage should be140 V- 270 V, Driver frequency 50Hz Power factor>0.9, Lumen output should not be less than 100 Lumen/watt and Luminaire Driver ckt should be moulded type weather proof construction, with separate surge protection device 5ka rating and separate connector block for termination of incoming cable connection all as specified and directed by Engr -in-Charge. |
| 16 | S & F in repair of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), including taking down existing complete as specified and directed. Make: Havells/Crompton/Bajaj |
| 17 | S&F in repair of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete as directed.Make: Havells/Bajaj/Crompton/Orient Electric |
| 18 | Supply & fix exhaust fans single phase 50HZ AC supply , 230/240 V of size 300 mm sweep with blades, frame, louvers and robust metal body finished with corrosion resistant powder coating along with inbuilt thermal overload protection for safety against overheating complete all as specified and directed.Make: Havells/ Crompton/ Bajaj/Almonard |
| 19 | Supply & fix exhaust fans single phase 50HZ AC supply , 230/240 V of size 450 mm sweep with blades, frame, louvers and robust metal body finished with corrosion resistant powder coating along with inbuilt thermal overload protection for safety against overheating complete all as specified and directed.Make: Havells/ Crompton/ Bajaj/Almonard |
| 20 | Supply & fix exhaust fans single phase 50HZ AC supply , 230/240 V of size 380 mm sweep with blades, frame, louvers and robust metal body finished with corrosion resistant powder coating along with inbuilt thermal overload protection for safety against overheating complete all as specified and directed.Make: Havells/ Crompton/ Bajaj/Almonard |
| 21 | Note: Deduct Credit for demolished / dismantled material of Rs. (-) 30,929.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 14 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender