Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57179913

Tender For Repair/ Maintenance Of Cold Room, Window And Split Ac, Water Cooler And Deep Freezer Including Precision Ac At Blo, Hq Gna, Gmk, 2W Det, Ncb, Comcen, Ncn And Inhs Jeevanti Under Ge Gomantak Vasco

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
42 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
17 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Cold Room, Window And Split Ac, Water Cooler And Deep Freezer Including Precision Ac At Blo, Hq Gna, Gmk, 2W Det, Ncb, Comcen, Ncn And Inhs Jeevanti Under Ge Gomantak Vasco

BOQ

Name of Work:- Repair/ Maintenance of cold room, window and split AC, water cooler and deep freezer including Precision AC at BLO, HQ GNA, GMK, 2W DET, NCB, COMCEN, NCN and INHS Jeevanti under GE Gomantak Vasco
Sl. No. Item Description
1M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for the following capacity of water cooler / refrigerator/Deep freezer :- (a) Water coolers 40 to 150 ltrs cooling capacity.
2(b) Refrigerator 165 to 310 Ltr capacity
3(c) Deep Freezers 200 to 425 ltrs capacity
4Supply and charging refrigerant gas R-12/R-134 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any Make Paragon, Mefron complete all as specified and directed for the following capacity of water cooler / refrigerator/Deep freezer :- (a) Water cooler of 40 to 150 ltrs capacity.
5(b) Refrigerator 165 to 310 Ltr capacity
6(c) Deep Freezers 200 to 425 ltrs capacity
7Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed for the following capacity of water cooler / refrigerator/Deep freezer :- Make :Emerson, Kirloskar, Voltas(a) Water coolers of 40 to 150 ltrs capacity
8(b) Refrigerator 165 to 310 Ltr capacity
9(c) Deep Freezers 200 to 425 ltrs capacity
10Supply and replace starting relay as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity
11(b) Refrigerator 165 to 310 Ltr capacity
12(c) Deep Freezers 200 to 425 ltrs capacity
13Supply and replace thermostats as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity
14(b) Refrigerator 165 to 310 Ltr capacity
15(c) Deep Freezers 200 to 425 ltrs capacity
16Supply and replace condenser unit including making of all connections as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity
17(b) Refrigerator 165 to 310 Ltr capacity
18(c) Deep Freezers 200 to 425 ltrs capacity
19Supply and replace cooling coil as per existing suitable for the following capacity of water cooler / refrigerator:- (a) Water coolers of 40 to 150 ltrs capacity.
20(b) Refrigerator 165 to 310 Ltr capacity
21Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.
22Supply and replace overload protector as per the existing make of the following :-(a) Water coolers/ Refrigarator upto 350 ltrs cooling capacity.
23(b) Deep freezers of upto 425 ltrs capacity.
24Supply and replace ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule of the following sizes :- (a) 15mm dia
25(b) 20mm dia
26Supply and fix PVC insulated and overall PVC sheathed circular flexible 3 core 4 sqmm copper conductor cable including disconnecting and removal of old cable complete all as specified and directed.
27Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames as per existing suitable for the following capacity of water cooler / Deep freezer:- (a) Water coolers of any make and cap 40 to 150 ltrs.
28(b) Deep Freezers 200 to 425 ltrs capacity
29S&F in replacement of existing unsv Gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for pipe of size 15 mm bore complete all as specified and directed.
30All as per item No. 29 above but 20 mm bore
31S&F in repair bib taps, cast copper alloy with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
32All as per item No. 31 above but 20 mm bore
33Dismantling and removing of defective burnt motor from unit and rewinding the motor with super enamel copper winding wire including replacement of worn out motor bearing, refixing and testing as per existing suitable for the following capacity of water cooler / Deep freezer:- (a) Water coolers of any make and cap 40 to 150 ltrs.
34(b) Deep Freezers 200 to 425 ltrs capacity
35Supply and replace internal wiring complete suitable for :-(a) Water coolers of any make and cap 40 to 150 ltrs.
36(b) Deep Freezers 200 to 425 ltrs capacity
37Supply and charging refrigerant gas R-22/R-32 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed.Make Paragon, Mefron (Note: Above second floor contractor will arrange crain / scaffolding with safety device)(a) Window type AC of capacity 1/1.5 Ton.
38(b) Split type AC 1.5/2.0 Ton capacity
39M&L for servicing of Split type AC 1.5/2 Ton capacity comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation (Note : Above second floor contractor will arrange crane / scaffolding with safety device)
40M&L for applying two coats of synthetic enamel paint using spray machine on outer unit of split type AC including preparation of surface complete all as directed. (Note : Above second floor contractor will arrange crane / scaffolding with safety device)
41Supply and replace compressor sealed unit of the following appliances complete including replacement of copper tubing/ capillary strainer etc, testing and commissioning all as specified and as directed. (Note : Above second floor contractor will arrange crane / scaffolding with safety device)Make : Emerson, Kirloskar, LG(a) Window type AC of capacity 1/1.5 Ton.
42(b) Split type AC 1.5/2.0 Ton capacity.
43Supply and replace capacitors of the following capacities for ACs Make : Siemens, Epcos, Universal(a) 4/6 Mfd
44(b) 10 Mfd
45(c) 36 Mfd (Six Pin)
46(d) 80/100 Mfd
47(e) 120 Mfd
48(f) 45+6 Mfd Seven Pin
49M&L for cutting out worn out bottom portion and fabricating/ welding properly of bottom tray with suitable size of GI plate and welding of legs including supply and fixing of suitable size of angle iron legs to match existing of split type AC Unit any capacity complete all as directed.
50Supply and replace starting relay suitable for Split type AC 1.5/2 Ton capacity complete all as directed.
51Supply and replace thermostats suitable for Split type AC 1.5/2 Ton capacity complete all as directed.Make: Danfoss, Annapurna
52Supply and replace overload protector suitable for Split type AC 1.5/2 Ton capacity complete all as directed.Make Usha, Annapurna
53Supply and replace condenser unit made of copper suitable for Split type AC 1.5/2 Ton capacity including making of all connections as specified and directed.Make: LG, Voltas, Whirpool
54Supply and replace of evaporator coil suitable for Split type AC 1.5/2 Ton capacity complete all as directed.
55S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25/32 mm wide PVC casing and capping with all accessories such as Tee, elbow, junction box, reducers etc. including making good the disturbed wall surfaces to match with existing specification. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
56S&F in replacement sheet metal enclosures, single pole with socket, plug top and one single pole MCB 20 Amps, 240 V complete all as specified and directed.
57S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
58Supply and replace contact unit of split type AC 1.5/2 Ton capacity.
59Supply and replace internal wiring complete suitable for Split type AC 1.5/2 Ton capacity complete all as directed.
60Dismantling and removing of defective burnt motor from Split type AC of any make and capacity 1.5/2 ton. and rewinding the motor with enamel copper winding wire incl replacement of worn - out motor bearing, refixing and testing all as directed
61Supply and replace blower/condenser fan motor complete with necessary mounting bracket and base frames for Split type AC of any make as per existing and capacity 1.5/2 ton complete all as directed.
62Supply and fix in repair indoor fan unit complete suitable for cool room/cold room to match exisitng make and capacity all as directed.
63Supply and fix in repairs 15 mm dia drain pipe heavy duty PVC flexible pipe with necessary fittings of jubilee/ Split AC's/ Window AC's complete all as directed.
64Supply and fix Air filter suitable for 1.5/2.0 ton split type AC of any make all as directed.
65Supply and fix insulation for copper tubes of split type AC units, insulation type superlon of size 3/8\\" diameter all as directed.
66Supply and fix insulation for copper tubes of split type AC units, insulation type superlon of size 5/8\\" diameter all as directed.
67Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8\\" diameter all as directed.
68Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8\\" diameter all as directed.
69Taking down of Split type AC (Indoor & out door with mounting bracket & voltage stabilizer) of any capacity from existing place and Reinstalling the same in another location complete and testing & commisioning all as specified and directedNote : New spares required for replacing (mounting bracket, insulation for copper and copper tubing) shall be measured and paid seperately.
70Supply and fix PCB (Printed circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC indoor unit all as directed. Make: LG, Voltas, Daikin
71Supply and fix PCB (Printed circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC out door unit all as directed. Make: LG, Voltas, Daikin
72Supply and fix PCB (Printed circuit board) complete suitable for 1.5/2.0 ton capacity non Inverter type split AC out door unit all as directed. Make: LG, Voltas, Daikin
73Supply and replace of Heating element of cold room door as per existing make at site, as directed and specified.
74Supply and replace of Thermostat of cold room door heater as per existing make at site, as directed and specified.
75S&F handle with locking facility of cold room door of existing make and size complete all as directed.
76S&F MS stand factory made for installation of condensing unit on the wall/ ground duly powder coated all as per existing size complete all as directed.
77Supply and fix in repair remote control as per existing make of any size and capacity of split AC all as directed.
78Supply and fix in repair Voltage stabilizer Capacity of 5 KVA of range 130 V to 180 V suitable for up to 2 Ton split AC all as directed. Make: V-Guard/MicroTek/Luminous.
79Supply and fix in repair indoor cooling unit with rotary fan suitable for 1.5 ton Split AC all as directed.Make: LG, Voltas, Daikin
80Supply and fix in repair indoor cooling unit with rotary fan suitable for 2 ton Split AC all as directed.Make: LG, Voltas, Daikin
81Supply and fix in repair outdoor unit with rotary fan suitable for 1.5 ton Split AC all as directed.Make LG, Voltas, Daikin
82Supply and fix in repair outdoor unit with rotary fan suitable for 2 ton Split AC all as directed.Make LG, Voltas, Daikin
83Supply and installing electrical cold room panel, three phase supply, 415 Volts, AC supply showing display temperature, voltage, current and humidity complete all as specified and directed.
84S&F in repair PCO5+ suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site
85S&F in repair PGD1 display suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site
86&F in repair expansion board suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site
87S&F in repair tLAN Card suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site
88S&F in repair Pressure Transducer suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site
89S&F in repair NTC Sensor suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site
90S&F in repair CT suitable for PRECISION AC complete all as specified and directed.Make:- Carel or equivalent as per existing make at site
91S&F in repair Power supply (SMPS) suitable for PRECISION AC complete all as specified and directed.
92Charges for Mechanic Net-working Programming for PRECISION AC complete all as specified and directed.
93S&F in repair Retrofitting suitable for PRECISION AC complete all as specified and directed.
94S&F in repair 7HT Temp Sensor suitable for PRECISION AC complete all as specified and directed.NOTE FOR ITEM NO. 84 to 94 :- Work will be executed through authorised person of company. In this regard necessary certificate along with bill of authorised service partner of company will be submitted by contractor before payment. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57179913
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Cold Room, Window And Split Ac, Water Cooler And Deep Freezer Including Precision Ac At Blo, Hq Gna, Gmk, 2W Det, Ncb, Comcen, Ncn And Inhs Jeevanti Under Ge Gomantak Vasco
Basic Detail
Tender No 8834/E8
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 24 Aug 2026
Submission Date 15 Sep 2026
Open Date 17 Aug 2026
Finance
Tender Value 42 Lakhs
Tender Fee 500
EMD 84000
Exemption Available
Document List
BOQ_880858.xls
dc4ed2a8-41d8-47a2-85d8-8c7a71d6965e.html
tender8834.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_880858.xls

html

dc4ed2a8-41d8-47a2-85d8-8c7a71d6965e.html

pdf

tender8834.pdf

pdf

Tendernotice_1.pdf