Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #57179911

Tender For Repairs Replacement, Cleaning Of Sewage Line Manholes, Wc And Bathroom And Drainage Including Drain Cover And Cleaning Of Septic Tank Manholes Sewage Line At Residential Complex And Otm Accn At Ghatkopar And Vikhroli Under Ge (North) Santa

Issued by Statutory Bodies & Commissions/Committees · Mumbai Suburban, Maharashtra
Tender Value
25 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
14 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs Replacement, Cleaning Of Sewage Line Manholes, Wc And Bathroom And Drainage Including Drain Cover And Cleaning Of Septic Tank Manholes Sewage Line At Residential Complex And Otm Accn At Ghatkopar And Vikhroli Under Ge (North) Santacruz.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Aug-2026 Other corrigendum Other 14-Sep-2026

BOQ

Name of Work:- REPAIRS REPLACEMENT, CLEANING OF SEWAGE LINE MANHOLES, WC AND BATHROOM AND DRAINAGE INCLUDING DRAIN COVER AND CLEANING OF SEPTIC TANK MANHOLES SEWAGE LINE AT RESIDENTIAL COMPLEX AND OTM ACCN AT GHATKOPAR AND VIKHROLI UNDER GE (NORTH) SANTACRUZ.
Sl. No. Item Description
1Excavation in trenches n. exc 1.50m wide and n. exc 1.50m deep and getting out in soft / loose soil complete all as specified and as directed by Engr-in-Charge.
2Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft / loose soil complete all as specified and as directed by Engr-in-Charge.
3Returning, filling in including spreading, levelling, watering and well ramming in layer n. exc 25cm in soft / loose soil complete all as specified and as directed by Engr-in-Charge.
4Removing excavated soil to a distance exceeding 1.5 Km but not exceeding 5 Km out of MD land complete all as specified and as directed by Engr-in-Charge.
5Demolition and breaking up drain pipes (slat glazed stoneware, AC or RCC) set in cement mortar for 200mm bore of pipe complete all as specified and directed. Note: Earth work shall be measured and paid separately
6Demolition and breaking up drain pipes (slat glazed stoneware, AC or RCC) set in cement mortar for 150mm bore of pipe complete all as specified and directed. Note: Earth work shall be measured and paid separately
7Material and labour for reinforced concrete pipes 200mm bore with collars, class NP-2 laid in trenches and jointed in cement mortar 1:1 with spun yarn etc complete all as specified and as directed by Engineer-in-Charge.
8Material and labour for reinforced concrete pipes 150 mm bore with collars, class NP-2 laid in trenches and jointed in cement mortar 1:1 with spun yarn etc complete all as specified and as directed by Engineer-in-Charge.
9M&L for concrete bed to 200 mm sewage pipes in cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed
10M&L for concrete bed to 150 mm sewage pipes in cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed
11Material and labour for cutting into existing manholes for 150mm internal dia of pipes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and reforming benching as required complete all as specified and as directed
12Demolition of brick work/stone masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, PCC coping etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing of debris outside MD land complete all as specified and as directed.
13Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) removing of debris outside MD land complete all as specified and as directed.
14M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
15All as per item No.14 described here-in-before but except brick built in cement mortar 1:6.complete all as specified and as directed.
16M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in 1/2 brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
17M&L for 25mm thick Sand filling under floors or in foundation including watering and consolidation.
18M&L for 50 mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of flooring/ hard standing path and finishing the surface even and fair without using extra cement all as specified and directed.
19M&L for Machine pressed precast concrete interlocking paver block any shape and any size conforming to IS 15658-2006 of 60mm thickness M-35 grade set and jointed gray cement pigment to match in floor complete all as specified and as directed.
20Taking down cement plaster on brick or stone walls etc incl racking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
21M&L for rendering 15 mm thick in cement mortar 1:4 (10 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid separately) complete all as specified and directed.
22Supply only integral water proofing compound complete all as specified and directed.
23M&L for cement concrete 1:2:4 Type B-2 using 40mm graded stone aggregate as in foundations Fillings and Mass concrete as the foundation of manholes complete all as specified and as directed
24M&L for cement concrete 1:2:4 type B-2 using 20mm graded stone aggregate as in benching of manhole and for surface channels and drains including necessary form work complete all as specified and as directed by Engr-in-Charge.
25M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/ stopped ends etc complete all as specified and as directed
26Demolition of reinforced cement concrete of manhole covers etc complete all as specified and directed.
27M&L for providing precast reinforced cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for manhole / drain covers etc. set in cement mortar 1:6 finishing the exposed faces even and smooth without using extra cement including demolition of existing unserviceable RCC covers and removing debris out side MD land complete all as specified and as directed.Note :- Reinforcement shall be measured and paid separately.
28M&L for TMT bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified.
29All as per item No.28 but 6mm to 8 mm dia as in stirrups, spacers, binders, nibs for fencing posts complete all as specified and directed.
30M&L for cleaning of manhole of any type/size/thickness and cleaning manhole chamber of any shape & size not exc. 1.50 metre deep by removing sludge/mud from manhole spreading bleaching powder on the silt removed to avoid bad smell including cleaning of surrounding area of manhole upto 1.0m from the edges etc complete all as specified and as directed
31M&L for cleaning of all blockage of WC, bath, kitchen, WHB, traps, soil waste/vent pipe (vertical or laid in trenches/floor any type/size), sewage line upto 1st man hole of any section/depth any situations by way of cleaning/desludging man holes by using any type of manually or mechanically or by way of any other suitable means including foreign material from manholes, traps, pits where required and directed by Engineer-in-Charge and keeping the sewage system upto 1st man hole functional in prefect condition including final drop out form up to 1st man hole. (working in foul condition with taking precautionary measures equipment shall be provided as required are applicable) all as specified and directed. Note- Rate inclusive of cleaning from ground floor to first floor
32All as per item No.31 but above from 2nd floor to 4th floor
33Pumping out water inflow caused by spring or tidal or river seepage, broken water mains or sewage drains line, manhole and the like with pumping set of 5 HP to 9 HP including POL/power consumption & operator maint etc. complete all as specified and directed.Note : This item shall be operated only when specifically ordered .
34Systematically cleaning mud from the drain of any size and depth including all precautionary and safety measures as required and removing the debris out side MD land complete all as specified and as directed.
35S&F in repair vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
36S&F in repair, vitreous china squatting pan,' Orissa' pattern, size 580x440mm white , with integral foot res (excluding flushing cistern flush pipe and waste pipe complete all as specified and directed.
37S&F in repairs PVC low level flushing cistern of capacity 10 ltr. white with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or PVC 32mm dia and connection to pipes and fixing of chains and pull or lever.
38Material and labour for cleaning of septic tank (500 users) (hume pipe / masonry), by opening cover, pumping out liquid sludge/waste materials, taking out sludge night soil etc and taking off the waste outside MD land as per BMC rules and placing the existing cover in original position making good the joints and taking all precautionary and safety measures such as gas mask, use of safety belt and cell torch for lighting inside septic tank, including spreading bleaching powder on the silt removed to avoid bad smell complete all as specified and as directed.
39All as per item No.38 described here-in-before but capacity of septic tank 250 users.
40Material and labour for removing vegetation, trees, plants and shrubs etc in any position by cutting hole in to brick wall/concrete surface (for removing the roots of trees/plants) area n. exceeding 0.50 sqm each and using acid to burn the all roots of tree/plants and making good disturbed surface with cement concrete (1:2:4) type B1 using 20mm graded aggregate mixed with water proofing compound by 3% of weight of cement and including making good adjoining surface including existing finishes complete all as specified and as directed by Engineer-in-Charge.Note - The rate is including necessary scaffolding work .
41Dismantling of 110mm dia cast iron / PVC pipes jointed in cement mortar and taking out if reqd complete all as specified and as directed.
42Dismantling of 75mm dia cast iron / PVC pipes jointed in cement mortar and taking out if reqd complete all as specified and as directed.
43S&F PVC SWR Single socketed rain water pipes/soil waste pipes with rubber ring joints 110mm dia fixed to wall complete all as specified and as directed.
44S&F PVC SWR Single socketed rain water pipes/soil waste pipes with rubber ring joints 75mm dia fixed to wall complete all as specified and as directed..
45S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and as directed.
46S&F in repair 110mm PVC (SWR) branch piece, Single (single Y) equal or unequal complete all as specified and as directed.
47S&F in repair 75mm PVC (SWR) branch piece, Double (single Y) equal or unequal complete all as specified and as directed.
48Note: (i) All the sewage/ cleaning works shall be carried out through mechanical mode only. (ii) Deduct Credit for demolished / dismantled material of Rs. (-) 17,815.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57179911
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs Replacement, Cleaning Of Sewage Line Manholes, Wc And Bathroom And Drainage Including Drain Cover And Cleaning Of Septic Tank Manholes Sewage Line At Residential Complex And Otm Accn At Ghatkopar And Vikhroli Under Ge (North) Santacruz.
Basic Detail
Tender No 8338/E8
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 27 Aug 2026
Submission Date 14 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
BOQ_880852.xls
e052cd59-ec5f-4feb-81dc-ecca70f85b43.html
GENPAGES8338.pdf
PS8328.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 14 days
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_880852.xls

html

e052cd59-ec5f-4feb-81dc-ecca70f85b43.html

pdf

GENPAGES8338.pdf

pdf

PS8328.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders