Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #57179897

Tender For Repairs And Systematic Cleaning To Sewage Lines And Manholes, Including Associated Allied Works At Crms Shakurbasti In Aor Of Age Br -Ii Under Ge (North) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
30 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
12 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs And Systematic Cleaning To Sewage Lines And Manholes, Including Associated Allied Works At Crms Shakurbasti In Aor Of Age Br -Ii Under Ge (North) Delhi Cantt-10

BOQ

Name of Work:- REPAIRS AND SYSTEMATIC CLEANING TO SEWAGE LINES AND MANHOLES, INCLUDING ASSOCIATED ALLIED WORKS AT CRMS SHAKURBASTI IN AOR OF AGE BR -II UNDER GE (NORTH) DELHI CANTT-10
Sl. No. Item Description
1Cleaning of blockage of bathroom kitchen by cleaning Nahani trops gually traps and removing of all the mud/sludgs and getting out washing thoroughly grating oof trap CI waste pipes by opening the cleaning eyes and depositing the slugs in a pit of suitable size at a distance exceeding 50 meters from the gully trap and converting the same with the soil obtained from the excavation and earthwork complete all as specifed and as directed by Engineer in charge
2Cleaning of blockage WC indian pattern or european for removing of all the mud/sludgs and getting out including cleaning SGSWG or GI pipe upto 1st manhole and depsoting the sludgs in a pit of suitable size at a distance exceeding 50 meters from the gully trap and converting the same with the soil obtained from the excavation and earthwork complete all as specifed and as directed by Engineer in charge
3M&L for cleaning of blocked sewage line, any type of dia in horizontal or vertical position from manhole to manhole drain pipes. Note:- Cleaning of sewage line of any type and dia or bore upto any depth by removing all filts/silts, foreign material and other deposits whatever completely and making the line free from all obstacles and testing the flow of sewer line evently, smoothly by filling water. The cleaning operation will be carried out in suitable length by blocking the first and last manhole of sewer line and removing the silt/sludge & deposits out side of defence land in covered van/Trolly all as specified and directed by Engr-in-Charge.rate.
4Cleaning of manhole any depth of any size of manhole and taking out sludge and depositing the same in notified area by Municipal Corp of Delhi for dumping or out side Defence land complete all as specified and as directed.
5Cleaning of sewage line, man holes and septic tank (any size/any depth) etc using mechanically oprated Hydraulic pressure machine equpied with jet and suction pressure cleaning all as specified and directed. (08 working hours for one job). Note:- work will be executed in foul condition
6Dewatering/desludging of septic tanks, soakage wells etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and burried off the same out side the defence area notified by Municipal Corporation of Delhi all as specified and as directed by Engr-in-Charge.
7S&F PVC (SWR) pipes, 110 mm external dia, type-B, ISI marked (IS:13592) double socketed in any length with rubber ring joints, fixed to walls etc with ms clampsMS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified. MAKE: SUPREME, FINOLEX, PRINCE .
8S&F PVC (SWR) bends suitable for 110 mm external dia with or without access door complete all as specified
9S&F in repair SFRC manhole covers with and including frame medium duty over all size 1000 mm x 500mm x 80mm thick factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked all as specified by Engr-in-Charge
10Excavation in any type of soil in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out complete all as specified and as directed.
11Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and as directed.
12Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil omplete all as specified and as directed.
13M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 100mm internal dia SGSW / RCCpipes after they are laid and tested including demolition of old bed and pipes omplete all as specified and as directed. (thickness of concrete bed 100mm & Width of bed :- outer dia of pipe plus 30 cm.).
14M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia SGSW / RCCpipes after they are laid and tested including demolition of old bed and pipes omplete all as specified and as directed. (thickness of concrete bed 100mm & Width of bed :- outer dia of pipe plus 30 cm.).
15All as per ser the description of srl item No 14 above here-in-before but for 200 mm internal dia SGSW pipes/ RCC pipes (thickness of concrete bed 150mm).
16M&L for 100mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
17M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
18M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
19M&L for 200mm bore Reinforced concrete pipes, class NP2, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
20M&L for 150mm bore Reinforced concrete pipes, class NP2, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
21Cutting into existing manholes for connecting new drains, of 100 mm to 300 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
22Demolition of Concrete of any description and in any position not otherwise specifically provided for.
23Demolition of brick work or stone masonry built in cement mortar including all quoines arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified.
24Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) incl Dismantling of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified.
25M&L for PCC 1:2:4 type B0, using 12.5mm graded agg as in coping, kerbs or mud stops, rounded or chamfered on edges completed as specified.
26M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains, side guide wall including all necessary form work complete all as specified and directed.
27M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
28Taking down cement plaster on brick walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
29M&L for rendering 15mm thick Plaster on fair face of brick surface in cement mortar 1:4 mixed with PD proof 101 LW(+) of Dr fixit or equvalant integral WP admixer @200 ml/bag of Ready mix over two coats of super latex 302 of Dr fixit or equ. in the ratio 1:4: 7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 Kg of homogenious mixture per Sqm in two coats on brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. Note:- PD proof 101 LW(+) and super latex 302 shall be measured and paid separately
30Supply only PD proof 101 LW (+) of Dr Fixit or equivalent.
31Supply only super latex 302 of Dr fixit or equivalent.
32M&L for plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate, 75mm thick as in plinth protection/pavment and the like, finish the surfaces even and fair complete all as directed and specified
33M&L machine pressed precast rubber mould coloured concrete interlocking paver blocks of 60 mm thick any shape and size conforming to IS 15658-2006 ,M-35 grade with grey cement and no pigment over complete all as specified and directed.
34Supply only 40mm thick Sand filling under floors or in Foundation including watering & consolidation etc complete all as spd.
35Demolition of cement concrete (reinforced) of any description and in any position not other wise specifically provided for all as specified.
36S&F for precast reinforced cement concrete Manhole covers or drain covers in 1:2:4 using 20 mmgraded stone agg and set in CM 1:4 all as specified and directed by Engineer-in-Charge.
37M&L for mild steel TMT bars 10 to 12mm dia and over, cut to length, bent to shape required including cranking bending, spirally for hooping end and binding with and incl mild steel wire (annealed) not less than .9mm dia or securing with clips quality confirming Fe 410S or Fe-410O
38M&L demolition of precast concrete articles and precast concrete block walling built in cement mortar all as specified and directed.
39M&L for providing precast reinforced cement concrete type B0, 1:2:4 using 12.5mm graded aggreagte as in loures and jallies 35mm thick (measured solid) including al mouldings set in cement mortar 1:4, complete all as specified and directed.
40M&L PCC 1:4:8, type D2, using 40 mm graded aggregate 75 mm thick as in sub floor, Sub base, floor complete all as specified & directed.
41M&L Chequered cement concrete tiles 300mm x 300mm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement and pigment over screed bed or bedding layers of mortars 15 mm thick in CM 1:6, all as specified and as directed.
42Cleaning of over head water tanks of capacity 1000litrs with suction pump removing all scales and finally cleaning with fresh water etc, all as specified and directed.precaution should take to avoid outlet pipe from blocking and date of cleaning should be mentioned out side tank.
43All as per the description of srl item No 42 but tanks of capacity 500litrs Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57179897
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs And Systematic Cleaning To Sewage Lines And Manholes, Including Associated Allied Works At Crms Shakurbasti In Aor Of Age Br -Ii Under Ge (North) Delhi Cantt-10
Basic Detail
Tender No GE/NORTH-127/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 24 Aug 2026
Submission Date 14 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
BOQ_880808.xls
c336f8bf-10f5-4d5d-8d2e-101043c0f4b8.html
Gen127.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_880808.xls

html

c336f8bf-10f5-4d5d-8d2e-101043c0f4b8.html

pdf

Gen127.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders