Tender for Repair To Roof Treatment And Connected Works In Sector ‘A, Joshi Enclave, Fafa & Pine Marg Under Age B/R -I At Chandimandir
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar including removal of any existing treatment complete all as specified & directed. |
| 2 | Demolition of mud Phuska in roofs, any thickness incl plastering and leeping etc (whether full thickness removed or only a part thereof) complete all as specified & directed. |
| 3 | Removal of excavated material outside MoD land not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 4 | 40mm thick PCC 1:2:4 type B-0 (using 12.5m graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement, complete all as specified and directed. |
| 5 | 10mm thick rendering in Cement and Sand mortar 1:4 over roof slab finished even and fair mixed with water proofing compound as per manufacturers instruction complete all as specified.Note : WPC shall be measured and paid separately. |
| 6 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 7 | Roof treatment with water proofing compound complete all as specified and directed. Make: Pidilite/ Fosroc/Asian Roof With Sound Brick Bat Coba / China Mosaic/ Ceramic Tile & Concrete Screed IPS Having Proper Slope Area. Dr. Fixit Wonderproof 100 - primer less and hybrid urethane elastomeric waterproofing coating. Roof treatment with WPC will be divided into following stages as under and will be certified by technical rep of company whether the stages completed are as per manufacturer’s instruction and finally passed by Engr-in-Charge/GE:- |
| 8 | Surface Preparation:All loose and de-bonded concrete/ screed, grass, roots, loose particles, dirt & shall be removed. Roof substrates must be pressure-washed with water with a minimum working pressure of 1,400 psi to be used to and/or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution or biowash. |
| 9 | Crack Repair:All visible hairline cracks on concrete roof screed more than 0.50 mm and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size (8mm W x 6mm D). any filling of cracks with Dr. Fixit PU sealant / Hybrid Sealant with suitable gun and smoothed with a putty knife or trowel. Allow sealant to cure a minimum (72 Hrs.) 3 days. |
| 10 | Screed Repair:Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jet to remove dirt and loose particles. brush apply a bond coat of Dr. Fixit Pidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface. laying of fall roof screed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10% by weight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water per cum of concrete. Level the repair mortar and finish with trowel. Moist cureof screed should be done for 7days. followed by Air curing screed for 4-5 days, before application of roof treatment. |
| 11 | Rainwater outlets treatment: Hacking and chipping the surface around the rainwater drain outlet up to25mm in depth. Apply bond coat of Dr. Fixit Pidicrete URP in the ratio of 1:1 (URP 1: Cement 1) by volume over the corners and pipe insert outlet gaps. Filling the gaps around drain mouth with (PMM) polymer modified mortar mixed with Dr. Fixit Pidicrete URP 10% by weight of cement in the ratio of 1:3. Providing & fixing 100 mm width 225-gsm g/m2 Fiberglass Chopped Strand Mat around the periphery of drain mouth of rainwater outlet sandwiched with Dr. Fixit Wonderproof 100. Apply two thick coats of Dr. Fixit Wonderproof 100 waterproofing coating to completely cover the mesh/fabric and surrounding area. |
| 12 | Vertical upstand:Providing 100mm x 100 mm Square / rectangle upstand of M20 grade concrete or with PMM around mechanical equipment like HVAC support air-conditioning unit solar panels. Etc. Applying two thick coats of Dr. Fixit Wonderproof 100 over the entire upstand, embedding it 225-gsm g/m2 Fiberglass Chopped Strand Mat while the Dr. Fixit Wonderproof 100 is still wet. Apply Dr. Fixit PU sealant / Feviseal Hybrid Sealant around the junction of fabricated stand inserted and wall mounting mechanical fixtures. |
| 13 | Waterproofing Application:Premix Dr. Fixit Wonderproof 100 Components A and B using an electric double-paddle mixer at low speed for 2–3 minutes until a uniform blend is achieved, without dilution. Apply the waterproof coating on an SSD (Saturated Surface Dry) condition. Apply the first coat at a rate of 0.80–0.90 kg/m² using a lamb’s wool roller. While the coating is still wet, roll and embed a 225 gsm Fiberglass Chopped Strand Mat, ensuring full bonding without air bubbles or wrinkles, and overlap joints by at least 5 cm at endpoints. Allow the first coat to dry for 3–4 hours. Apply the second coat at a 90° angle to the first coat at 0.70–0.80 kg/m² once the surface is dry enough to walk on. Additional coats may be applied as required to achieve a dry firm thickness a DFT of 1000 microns, with an overall material consumption of approximately 1.60 kg/m² over 2–3 undiluted coats. The coating should terminate below the drip mould on vertical surfaces. The system complies with ASTM and EN standards, achieving: Tensile Strength: ≥15 N/mm², Tear Strength: ≥100 N/mm,Dynamic Crack Bridging: EN 1062-7 & ASTM C1305-2016, Shore A Hardness: 85, Zero Water Permeability: at 10 bar (EN 12390-8:2019), Water Migration Resistance: No leakage, Low Temperature Flexibility: -20°C after 1000 hrs UV (ASTM D1970-2021), Solar Reflectance Index: 90 (ASTM E1980 for white). Peel Adhesion to Concrete (Wet Condition, 24 hrs): ASTM C794-12, The system confirms compliance with EN 13251:2016 for a 25-year service life when used with a 225-gsm fiberglass mat. It is backed by a 10-year waterproofing warranty from M/s Pidilite Industries Ltd. For vertical surfaces and parapet walls, apply Dr. Fixit Raincoat Classic or Dr. Fixit Raincoat Select as a protective waterproof coating. |
| 14 | Notes :1. Authorised applicator of the company with trained/ skilled workers will only be allowed to execute the work and the applicator will submit the authorization and experience certificate from the company. 2. The entire quantity of material will be calculated and brought on site as decided by Engr-in-Charge and will be accepted only post verification of PVs and Challan from the company through Mail. 3. Material will be kept in the custody of MES rep and will be issued to the authorised applicator as per requirement 4. Stage passing register will be properly maintained. 5. The contractor shall submit manufacturer generated 10 years warranty card during submission of RAR and Final Bill 6. A guaranty amount @ 10% will be kept as reserve till completion of warranty period and will be released thereafter.7. Any deterioration during the warranty period will be rectified by the manufacturer without any financial effect. 8. The roof in scope is accessible roof and following items of work are also going to be executed on the same roof:- (a) Demolition & Reconstruction of tank staging. (b) Replacement of GI pipe network. (c) Replacement of existing parapet wall with MS grill. (d) Demolition of existing protrusion of crumple joint and making it good by brick work. 9. The applicator will inspectthe site after all such works and inspect for any shortcomings. If any shortcoming is there, the same will be intimated to the Dept. Dept will get the same rectified. 10. The applicator will start the work only after satisfying himself about surface condition A confirmation in this regard shall also be submitted to dept.11. Ponding test shall be carried out for 72 Hrs after completion of roof treatment and ponding shall be done by applicator with company technical rep as per manufacturer’s instruction and finally passed/ directed by Engr-in-Charge/GE. |
| 15 | Disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning works etc and hoisting if required reconnecting and refixing in position of capacity exc 250 ltrs but n.exc 500 ltrs, complete all as specified & directed. |
| 16 | Disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning works etc and hoisting if required reconnecting and refixing in position of capacity exc 500 ltrs but n.exc 1000 ltrs, complete all as specified & directed. |
| 17 | 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, white in colour, screwable lid, hoisted and fixed in position, including PTMT ball valve 20mm bore & PTMT tank nipple, fixed as in repair complete all as specified and directed. |
| 18 | 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, white in colour, screwable lid, hoisted and fixed in position, including PTMT ball valve 20mm bore & PTMT tank nipple, fixed as in repair complete all as specified and directed. |
| 19 | Taking up or down steel tubing and connections 15mm bore, complete all as specified and directed. |
| 20 | Taking up or down steel tubing and connections 20mm bore ,complete all as specified and directed. |
| 21 | Steel water tubes, 15mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, complete all as specified and directed. |
| 22 | Steel water tubes, 20mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, complete all as specified and directed. |
| 23 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 24 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
| 25 | All as per serial item No 24 herein before but except bricks (using old serviceable bricks) –ditto- complete all as specified and directed. |
| 26 | Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. |
| 27 | Rendering 15mm thick in Cement and Sand mortar 1:4 over fair faces of brick / concrete ,finished even and smooth without using extra cement, including using water proofing compound, complete all as specified. Note : WPC shall be measured and paid separately. |
| 28 | PVC (SWR) rain water pipe, 110mm bore, single/ double socketed in any length with rubber ring joints, having minimum density 6 Kg/cm2 fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed. |
| 29 | 110 mm bore PVC (SWR) bends of any radius complete, fixed as in repair complete all as specified and directed. |
| 30 | Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish from outside MoD land complete all as specified & directed by Engineer-in-charge. |
| 31 | Cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). |
| 32 | Repair to RCC sunshades, chajjas, balconies, coloumns, bands, beams and similar RCC work at any position / height by dismantling loose / disintegrated portion including necessary scafolding and safety arrangements and fixing of reinforcement (cut to length, bent to shape required, including cranking, bending spirally including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips)/ chicken wire mesh wherever required and dubbing out with cement concrete 1:1.5:3, 15mm to 50mm thick, using 6 to 12mm graded stone aggregate to make up and finished the required shape including provision of necessary scaffolding and formwork up to four storey bldg if required and finished with 5mm thick rendering in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed. (NOTE : Supply only reinforcement and GI wire netting will be measured and paid separately under respective items) |
| 33 | Supply only chicken wire mesh of size 12.5mm x 1mm complete all as specfied and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysSep 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender