Tender For Retrofitting Of Essential Power Panel (Epp)/ Main Lighting Panel (Mlp) At Different Stations Of Line-1, 3E, 4 And 6
Tender Overview
Project Description
Tender for Retrofitting Of Essential Power Panel (Epp)/ Main Lighting Panel (Mlp) At Different Stations Of Line-1, 3E, 4 And 6
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Sep-2026 | Addendum 2 | Date | 29-Sep-2026 |
| 2 | 15-Sep-2026 | Addendum 1 | Date | 22-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Total of Schedule-A OEW-2284 APPENDIX- 3A PROFORMA FOR STATEMENT OF MINOR DEVIATIONS (Refer Clause C 2.2(d) and C 15.1 of ITT) 1. The following are the particulars of minor deviations from the requirements of the Tender Document: Sr. No Clause Deviations Price reduction for each deviation/s Note : 1. The Tenderer shall indicate price reduction against each deviation in Appendix-3A of BOQ. This price is the price which the tenderer shall reduce from this tender price if deviation(s) is/are accepted by the Employer. 2. Where there is no deviation, the statement should be returned duly signed with an endorsement indicating ‘No Deviations’. In case, Performa of deviations is not submitted or submitted as blank, it will be construed that the tenderer has not proposed any deviations from tender documents. 3. It shall be noted that in case Nil/Zero/NA Price quoted by Tenderer in Appendix-3A then it shall mean that contractor has quoted same price for deviation and undeviation bid. 4. If the tenderer proposes deviations in tender documents, and/or any other terms and conditions of the tender, other than in this Appendix, it will have no effect. Signature of authorized signatory On behalf of Tenderer Preamble OEW-2284 |
| 2 | The bill Quantities shall be read in conjunction with Notice Inviting Tenders, Instructions to tenderers, General and Special Conditions of Contract, Employers Requirements and other relevant documents |
| 3 | BoQ1 consists of Schedule ‘A’ . The rates and prices to be tendered in the unit Priced Bill of Quantities of Schedule ‘A’ , are for completed and finished items of works and complete in all respect. |
| 4 | Tenderers shall quote their offer in Indian Rupees (₹) only. |
| 5 | Tenderers shall quote their offer in Indian Rupees (INR) only. Tenderers are required to be quoted percentage (%) Excess/Less/At par for schedule-A in figures in the appropriate highlighted cells in the BoQ1 sheet. All the quoted rates will be deemed to include Duties, Taxes, Octroi, Royalty etc., cost of all plants, labour, supervision, materials, transport, all temporary works, erection, maintenance, utility identification, contractor’s profit and establishment/ overheads, together with preparation of design and drawings, all general risks, insurance liabilities, compliance of labour laws and obligations set out or implied in the contracts. For taxes and duties refer clause C2.5 of ITT & clause 10 of SCC. |
| 6 | The price offer in the BOQ shall be given without considering any deviation mentioned in Appendix-3 of FOT i.e. price in the box shall be quoted as per tender conditions without any deviation. |
| 7 | If the tenderer fails to quote percentage against BOQ item, the tender may be treated as incomplete and non- responsive and shall be rejected. |
| 8 | Errors will be corrected by the employer for any arithmetical errors in computation or summation as per contract conditions. |
| 9 | The Financial Proposal (as per BOQ) shall be uploaded online on the website http://etenders.gov.in/eprocure/app. The rates/ percentages shall be quoted in the excel file provided in the bid documents. The tenderer shall download the excel file and quote percentage in figures against BOQ amount in the appropriate highlighted cells in Excel sheet namely \\"BoQ1\\". After quoting their rates the excel file shall be uploaded accordingly. The rates shall not be offered/quoted elsewhere in the technical submission/ tender submission. |
| 10 | Bill of Quantities comprises of items/works to be executed as per Employer’s Requirements. |
| 11 | The work executed against all the BOQ as detailed in tender document would be paid as per clause 12 of Employer’s Requirements (ER). Please Enable Macros to View BoQ information DELHI METRO RAIL CORPORATION LIMITED Bill of Quantity (BOQ) Contract: OEW-2284 “Retrofitting of Essential Power Panel (EPP)/ Main Lighting Panel (MLP) at different stations of Line-1, 3E, 4 and 6” SCHEDULE- A Sl.No Description of work Unit ApprovedQty of L-1 Approved during finnace vetting Additional qty QTY M/s BPS Control Servicing Consultancy (P) LtdCP-38 to 44 M/s C&S ElectricCP-47 to 51 M/s Eaton CP-55 s.no.12 Note#41 OEW-1198CP-66 OEM-1535CP-78 Unit Rate (Excl. GST) Amount |
| 12 | Supply and retrofitting of MCCB 630A, 3 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt Trip coil-220VAC with Mechanical interlocking with same key complete with removing of old MCCB & control connection, automation and assembling the New MCCB 630A, 3Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 13 | Supply and retrofitting of MCCB 630A, 4 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt Trip coil-220VAC with Mechanical interlocking with same key complete with removing of old MCCB & control connection, automation and assembling the New MCCB 630A, 3Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 14 | Supply and retrofitting of MCCB 400A, 4 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt Trip coil-220VAC with same key complete with removing of old MCCB & control connection, automation and assembling the New MCCB 400A, 4Pole witht the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 15 | Supply and retrofitting of MCCB 400A, 3 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt Trip coil-220VAC with same key complete with removing of old MCCB & control connection, automation and assembling the New MCCB 400A, 3Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 16 | Supply and Retrofitting of MCCB 250A, 3 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC, with mechanical interlocking with same key complete with removing of old MCCB & control connection and assembling the New MCCB 250A, 3Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 17 | Supply and Retrofitting of MCCB 250A, 4 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC, with mechanical interlocking with same key complete with removing of old MCCB & control connection and assembling the New MCCB 250A, 4Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 18 | Supply and retrofitting of MCCB 300A, 3pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC with mechanical interlocking with same key complete with removing of old MCCB & control connection, automation and assembling the New MCCB 300A, 3Pole with the bus bar along with hardware support (like spreader link, bus bar modification, Mechanical interlocking kit, UV coil-220VAC, 1SY+1Q Aux Contact, Shunt coil -220VAC) etc complete job as per requirement of site conditionMake of MCCB:-Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 19 | Supply and retrofitting of MCCB 200A, 3pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC with removing of old MCCB & control connection and assembling the New MCCB 200A, 3Pole with the bus bar along with hardware support (like spreader link, bus bar modification, Mechanical interlocking kit, UV coil-220VAC, 1SY+1Q Aux Contact, Shunt coil -220VAC) etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 20 | Supply and Retrofitting of MCCB 63A, 3 pole in existing panel with microprocessor based protection-LSIG and removing of old MCCB with control cable/ support/ bus bar from the existing panel with the control connection and assembling the New MCCB 63A, 3Pole with the bus bar/ Hard cable along with support (like spreader link, bus bar modification, UV coil-220VAC, 1SY+1Q Aux Contact, Shunt coil-220VAC, Rotary handle) etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 21 | Supply and retrofitting of MCCB 100A, 3 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC and removing of old MCCB with control cable/ support/bus bar and assembling the New MCCB 100A, 3Pole with bus bar/ Hard cable along with support (like spreader link, bus bar modification, UVR, Aux Contact, Shunt coil) etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 22 | Supply and retrofitting of MCCB 100A, 4 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC and removing of old MCCB with control cable/ support/bus bar and assembling the New MCCB 100A, 4 Pole with the bus bar along with support (like spreader link, bus bar modification, UVR, Aux Contact, Shunt coil) etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 23 | Supply and retrofitting of MCCB 125A, 3 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC and removing of old MCCB with Control cable/ support/bus bar and assembling the New MCCB 125A, 3 Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 24 | Supply and retrofitting of MCCB 160A, 3 pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC and removing of old MCCB with control cable/ support/ bus bar and assembling the New MCCB 160A, 3 Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 25 | Supply and retrofitting of MCCB 160A, 4pole in existing panel with microprocessor based protection-LSIG including its rated spreader terminal, RHE (Rotary Handle Extended), Aux Contact block, UV coil-220VAC, Shunt trip coil-220VAC and removing of old MCCB with control cable/ support/ bus bar and assembling the New MCCB 160A, 4 Pole with the bus bar along with support etc complete job as per requirement of site conditionMake of MCCB:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 26 | Supply and retrofitting of MOE motorised suitable/compitable for 630A, 400A & 250A MCCB 3P/4P and remove the old MOE from existing panel with all hardware etc and assemble the motorized MOE set right the operating mechanism complete job as per requirement of site condition Make of MOE:- Empanelled make of DMRCNote:- Any modification is required for assembling of new MCCB including bus bar modification, panel cut out, Panel cover replacement, control wiring, filling of gap in panel cover etc is in scope of contractor. Work is to be executed in non revenue hours only. |
| 27 | Supply and retrofitting of power contactor in existing panel its wiring and termination, auxiliary supply 230V AC, 2 NO with 2 NC with following rating etc complete work in all respect or as per requirement of site condition including dismantling of old power contactor with their accessories, wiring etc.Work is to be executed in non revenue hours only. a 4 pole, 400A Nos 6.0 123377.0 740262.0 0.0 6.0 0.0 0.0 0.0 0.0 6.0 78600.0 Sl.No-16a 91890.0 Sl.No-16a 119457.0 Sl.No-16a 78600.0 471600.0 b 3 Pole, 400A Nos 2.0 113700.0 227400.0 0.0 2.0 0.0 0.0 0.0 0.0 2.0 92512.0 Sl.no-16b 98990.0 Sl.No-16b 128687.0 Sl.No-16b 92512.0 185024.0 c 3 Pole, 630A Nos 2.0 178560.0 357120.0 0.0 2.0 0.0 0.0 0.0 0.0 2.0 173336.0 Sl.No-16c 201490.0 Sl.No-16c 261937.0 Sl.No-16c 173336.0 346672.0 d 3 pole , 300A Nos 2.0 97891.0 195782.0 0.0 2.0 0.0 0.0 0.0 0.0 2.0 69184.0 Sl.No-16d 77550.0 Sl.No-16d 100815.0 Sl.No-16d 69184.0 138368.0 |
| 28 | Supply and retrofitting of power contactor in existing panel, its wiring and termination, auxiliary supply 230V AC, 1 NO with 1 NC with Aux contact block, 3 in Nos. etc complete work in all respect or as per requirement of site condition including dismantling of old power contactor with their accessories, wiring etc.Work is to be executed in non revenue hours only. a 3 pole, 110A Nos 6.0 29980.0 179880.0 0.0 6.0 0.0 0.0 0.0 0.0 6.0 38800.0 Sl.No-17a 31930.0 Sl.No-17a 41509.0 Sl.No-17a 29980.0 179880.0 b 3 pole, 63A Nos 4.0 15570.0 62280.0 0.0 4.0 0.0 0.0 0.0 0.0 4.0 27040.0 Sl.No-17b 15800.0 Sl.No-17b 20540.0 Sl.No-17b 15570.0 62280.0 |
| 29 | SITC of panel door lock as per requirement of site conditionWork is to be executed in non revenue hours only. |
| 30 | Fabrication and installation of panel door cover including welding, hinges, lock arrangement etc required as per site condition and removal of old cover for fitting of MCCB/ MOE as items mentioned above.Work is to be executed in non revenue hours only. |
| 31 | Supply and retrofitting of Cast resin type Current Transformer rating of 1000/5, Class- 0.5S, burden 15VA with complete wiring including dismantling of CT from existing location or as per requirement of site condition.Make- Empanelled make of DMRCNote: - Work is to be executed in non revenue hours only. |
| 32 | Supply and retrofitting of Cast resin type Current Transformer rating of 600/5, Class- 0.5S, burden 15VA with complete wiring including dismantling of CT from existing location or as per requirement of site condition.Make- Empanelled make of DMRCNote: - Work is to be executed in non revenue hours only. |
| 33 | Supply and retrofitting of Cast resin type Summation Current Transformer rating of 5+5/5, Class- 0.5S, burden 15VA with complete wiring including dismantling of CT from existing location or as per requirement of site condition.Make- Empanelled make of DMRCNote: - Work is to be executed in non revenue hours only. |
| 34 | SITC of LED panel indicator square type 22.5 mm dia, rated operating voltage 220-240 V, 50 HZ with following colourWork is to be executed in non revenue hours only. a Red colour Nos 0.0 986.0 986.0 0.0 0.0 0.0 986.0 986.0 170.0 Sl.No. 23a 380.0 Sl.No-23a 494.0 Sl.No-23a 170.0 167620.0 b Yellow Colour Nos 0.0 520.0 520.0 0.0 0.0 0.0 520.0 520.0 170.0 Sl.N. 23b 380.0 Sl.No-23b 494.0 Sl.No-23b 170.0 88400.0 c Blue Colour Nos 0.0 516.0 516.0 0.0 0.0 0.0 516.0 516.0 250.0 Sl.no. 23c 760.0 Sl.No-23c 988.0 Sl.No-23c 250.0 129000.0 d Green Colour Nos 0.0 482.0 482.0 0.0 0.0 0.0 482.0 482.0 170.0 Sl.No. 23d 380.0 Sl.No-23d 494.0 Sl.No-23d 170.0 81940.0 e Orange Colour Nos 0.0 418.0 418.0 0.0 0.0 0.0 418.0 418.0 170.0 Sl.No 23e 380.0 Sl.No-23e 494.0 Sl.No-23e 170.0 71060.0 f White colour Nos 0.0 1637.0 1637.0 0.0 0.0 0.0 1637.0 1637.0 250.0 Sl.No 23f 380.0 Sl.No-23f 494.0 Sl.No-23f 250.0 409250.0 |
| 35 | Supply and installation of three phase CT operated Energy meter with epoxy resin type 100/5A CT, energy meter indicate the following data;- KW, KVA, PF, KWH, KVAH, Line and phase voltage, Current, MD in KW, KVA and other associated electrical parameters as per standard. Make- Secure/ L&T with RS 485 communication port |
| 36 | Dismantling the control system with control wiring and ATS from the existing FPP panels & remove all the contractors/shut release/timers etc with other accessories. Re-arrangement all the system with the 1nos supply & 1 no DG supply on EPP set through contactor, timer, UVR, Push button, Selector switches, etc including wiring with suitable size FRLS wires, etc. also make the master supply with selector switch i.e supply no 1 & 2. Also fix the UVR 240 V ABB make in the existing MCCB of MLP &FPP as per the site condition to operate the supply at time one hold position from our of the three sources by providing suitable contactor, timer, push button, UVR, etc. as per the site requirements, interlocking control wiring complete job as per requirement. (a) 02 no. Incomer System (FPP) Nos 0.0 7.0 7.0 0.0 0.0 0.0 7.0 7.0 237769.0 Sl.No 24a 32000.0 Sl.No-24a 41600.0 Sl.No-24 58410.0 40273.695 34130.25 37543.28 Sch-A, 1 (d) 32000.0 224000.0 Total Amount of Schedule-A (Exclusive of GST) 32160152.8 ADD GST @ 18% 5788827.5 Total Amount of Schedule-A (Inclusive of All, GST @ 18%) 37948980.3 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender