Science and Technology Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57179472

Tender For Comprehensive External & Internal Repairs And Renovation Works Of Scientist Apartments (One Block Of Total 8 Nos) And External Repairs, Painting, Waterproofing And Termite Treatment Of Scientist Apartments (2 Blocks Having Total 32 Sqs) In

Issued by Statutory Bodies & Commissions/Committees · Bhavnagar, Gujarat
Tender Value
1.84 Crore
Estimated cost
Bid Submission
31 Aug 2026
5 days left
EMD
3.69 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhavnagar → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Comprehensive External & Internal Repairs And Renovation Works Of Scientist Apartments (One Block Of Total 8 Nos) And External Repairs, Painting, Waterproofing And Termite Treatment Of Scientist Apartments (2 Blocks Having Total 32 Sqs) In Hill Drive Colony Of Csir-Csmcri, Bhavnagar

BOQ

Name of Work:- Comprehensive external & internal repairs and renovation works of Scientist Apartments (One block of total 8 Nos) and external repairs, painting, waterproofing and termite treatment of Scientist Apartments (2 blocks having total 32 SQs) in Hill Drive Colony of CSIR-CSMCRI, Bhavnagar
Sl. No. Item Description
1PART-A CIVIL WORKEARTH WORK
2Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lif upto 1.5 m, as directed by Engineer-in- Charge:
3All kinds of soil
4Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
5All kinds of soil
6Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:
7All kinds of soil
8Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
9Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
10Pruning, trimming, shaping of trees /shrubs (ht 15 feet and above) i/c removal of cut materials upto 50mt. stacking of serviceable material and disposal of unserviceable material. Lead, as per direction of officer in charge. T&Pshall be arranged by the contractor
11CEMENT CONCRETE (CAST IN SITU)
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
131:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
141:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
15Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
16Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/ RCC/ Flooring/ water retaining structures by using 125 gram of synthetic Polyester triangular fibre for 50 kg cement used as per direction of Engineer-in-Charge.
17REINFORCED CEMENT CONCRETE
18Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
191:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
20Centering and shuttering including strutting, propping etc. and removal of form for
21Edges of slabs and breaks in floors and walls
22Under 20 cm wide
23Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
24Thermo-Mechanically Treated bars of grade Fe-500D or more.
25MASONRY WORK
26Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
27Cement mortar 1:4(1 cement :4 coarse sand)
28Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
29Cement mortar 1:4(1 cement :4 coarse sand)
30Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
31Cement mortar 1:3(1 cement :3 coarse sand)
32CLADDING WORK
33Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
34Granite stone slab of colour black, Cherry/Ruby red
35Area of slab over 0.50 sqm
36Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
37Granite work
38Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
39Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
40Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions/Bathroom quadrant shelves by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
41Granite Stone of approved shade
42Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
43WOOD AND P. V. C. WORK
44Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
45Second class teak wood
46Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)
47Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
48Second class teak wood
4930 mm thick
50Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
5130 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
52Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
53Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete:
5425 mm dia
55Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
56Fixed to openings /wooden frames with rawl plugs screws etc.
57Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :
58100x10 mm
59Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.
60Size 65 mm
61Providing and fixing magnetic catcher of approved quality in cupboard/ ward robe shutters, including fixing with necessary screws etc. complete.
62Double strip (horizontal type)
63Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
64Providing and fixing to existing door frames.
6530 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
66Providing and fixing cupboard shutter with 19 mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately)
67Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.
68200 mm
69Providing and fixing stainless steel sof closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge.
70Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per direction of Engineer- in-charge,
71STEEL WORK
72Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
73FLOORING
74Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
75Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
76Size of Tile 600x600 mm
77Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
78Glazed Vitrified tiles Matt/Antiskid finish of size
79Size of Tile 600 x 600 mm
80Providing and laying Vitrified tiles in diferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
81Size of Tile 600x600 mm
82Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
83Size of Tile 600x600 mm
84Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles.
85ROOFING
86Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
87110 mm diameter
88Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.
89Coupler
90110 mm
91Single tee with door
92110x110x110 mm
93Bend 87.5°
94110 mm bend
95Shoe (Plain)
96110 mm Shoe
97FINISHING
9812 mm cement plaster of mix:
991:4(1 cement: 4 fine sand)
10018 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge.
101Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
102Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
103Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
104Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
105Two coats
106Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
107With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
108Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping (using wall scraper machine), sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
109Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
110One or more coats on old work
111Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
112Old work (Two or more coats applied @ 1.43 V/ 10 sqm) over existing cement paint surface
113REPAIRS TO BUILDING
114Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
115With cement mortar 1:4 (1 cement : 4 fine sand)
116Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.
117Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
118Dismantling and Demolishing
119Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
120Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
121Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
122Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
123In cement mortar
124Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
125Of area 3 sq. metres and below
126Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
127Of area 3 sq. metres and below
128Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
129For thickness of tiles 10 mm to 25 mm
130Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :
13175 to 80 mm dia pipe
132100 mm dia pipe
133Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
134Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge.
135Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
136ROAD WORK
137Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
138Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost).
139SANITARY INSTALLATIONS
140Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
141Kitchen sink with drain board
142510x1040 mm bowl depth 225 mm
143Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
144WATER SUPPLY
145Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
14620 mm nominal dia Pipes
14725 mm nominal dia Pipes
14840 mm nominal dia Pipes
149Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15020 mm nominal dia Pipes
151Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
152DRAINAGE
153Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
154150 mm dia. R.C.C. pipe
155Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg
156Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
157Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
158With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
159Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :
160With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
161ALUMINIUM WORK
162Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
163For fixed portion
164Powder coated aluminium (minimum thickness of powder coating 50 micron)
165For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
166Powder coated aluminium (minimum thickness of powder coating 50 micron)
167Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
168With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
169Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
170Upto 5 mm depth and 5 mm width
171Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete.
172255 X 19 mm
173Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
174Powder coated minimum thickness 50 micron aluminium
175WATER PROOFING
176Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
177Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer- in-Charge.
178Credit Items (as per Local MR)
179Credit value item for selling of old scrapped reinforcement steel/ structural steel/ cast iron pipe on as is where is basis (rate of item will be considered negative).
180Buyback of old/existing wooden window of approximate size 1.52 meters x 1.35 meters/ panelled door of size 0.9 x 2.1m) , including wooden frame, shutters, and mild steel (MS) grill. The item includes taking over the removed material in as-is condition from the site. The rate shall include cost of material, loading, transportation, unloading, and all incidental charges complete as directed by the Engineer-in-Charge.(Note: Rate is considered as negative)
181Buyback of old/existing wooden windows of various sizes ranging from 0.60 meters x 1.35 meters to 0.90 meters x 1.35 meters, including wooden frames, shutters, and mild steel (MS) grills. The item includes taking over the removed materials in as-is condition from the site. The rate shall include cost of material, loading, transportation, unloading, and all incidental charges complete as directed by the Engineer-in-Charge.(Note: Rate is considered as negative)
182SOR Derived Items
183Providing and laying backfilling of dry broken brick/AAC block aggregates of 40 mm thick nominal size including spreading and grouting with coarse/fine sand, including finishing smooth etc. complete as per direction of Engineer-in- charge.
184Kota stone slab flooring over chajjah with 20 mm (average) thick base and embedding in wall by cutting a chase of appropriate width with chase cutter and embedding the kota stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) as per direction of Engineer-in-charge and finished smooth.
18525 mm thick
186Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives.
187New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers with elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) or as per per manufacturer specification as directed by Engineer In Charge.
188Providing and fixing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover with fitting of CPVC ball valve, CPVC connecting nipple, Brass elbow, Cpvc Elbow, Cpvc Union, brass float valve 25mm and suitable locking arrangement with making necessary holes for inlet, outlet and overflow pipes fittings and the base support for tank.
189Providing gola 75x75 mm in cement mortar 1:5(1 cement :5 coarse sand ), including finishing complete as Directed by Engineer In Charge.
190Providing and fixing machine cut, mirror/ eggshell polished, Granite stone work for door frame/ Window Jambs, sill including dado, skirting, risers of steps etc., in required design and pattern wherever required, at finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry @ 3.3 kg/sqm including pointing with epoxy grout with pigment of matching shade, including rubbing, curing, moulding and polishing of edges to give high gloss finish all complete as per directed by the Engineer-in-Charge.
191Granite Stone of approved shade
192Careful removal of existing MS grill from window/ventilator/opening, including repairs such as cutting, welding, straightening of bent members, , grinding, and surface preparation; and refixing the same in original or new position with proper alignment, including fixing with suitable anchoring arrangement complete in all respects with all labour, materials as directed by Engineer In charge.
193Fixed to openings /wooden frames with rawl plugs screws/ steel door by welding as required.
194NON SOR items
195Extra for providing and fixing Galvanised steel ‘base U’ clamps (Ghodi clamp) of approved design for fixing the unplasticised - PVC rain water pipes (or similar work) by means of nail, screwed with M.S. screws of required length, nut bolt, etc. complete as directed by Engineer In-Charge.
196For pipe of 75 mm dia
197for pipe of 110 mm dia
198Extra for providing and fixing Galvanised steel ‘base U’ clamps (Ghodi clamp) of approved design for fixing the unplasticised - PVC or GI water pipes (or similar work) by means of nail, screwed with M.S. screws of required length, nut bolt, etc. complete as directed by Engineer In-Charge.
199For 25-50 dia pipe lines
200Providing and fixing PVC SWR grade drainage fittings confirming to IS:14735 including fitting with required adhesive/rubber lubricant as per manufacturer's specification etc all complete for soil, waste and vent pipes as directed by Engineer In-Charge:
201W.C. Connector (Straight)
202110 mm dia
203Nahani Trap without Jali
204110 x 75 mm dia
205Single 'Y' with door
20675 mm dia
207110 mm dia
208Single 'Y'
20975 mm dia
210110 mm dia
211Single Tee
21275 mm dia
213110 mm dia
214Single Tee with door
21575 mm dia
216110 mm dia
217Bend 87.5 ﹾ
21875 mm dia
219110 mm dia
220Bend 87.5 with doorﹾ
22175 mm dia
222110 mm dia
223Double 'Y'
22475 mm dia
225110 mm dia
226Reducer 'Y' with door
227110 mm x 75mm size
228Double 'Y' with door
22975 mm dia
230110 mm dia
231Floor Drain Tile
232100 mm
233Reducing TEE
234110 x 75 mm size
235Reducing TEE with door
236110 x 75 mm size
237Bend 45
238Bend 45 ° 75 mm size
239Bend 45 ° 110 mm size
240NON SOR Item (CSPS SA WORK)
241Disconnecting water supply line with clamps and reconnecting with necessasry fitting required including providing and fixing Galvanised steel ‘base U’ clamps (Ghodi clamp) of approved design for fixing the unplasticised - PVC or GI water pipes (or similar work) by means of nail, screwed with M.S. screws of required length, nut bolt, etc. complete at every 3 feet as directed by Engineer In-Charge.
242For 25-50 dia pipe lines
243Providing and fixing Wall Mixer with provision for Overhead Shower with 115 mm Long Bend Pipe on Upper Side, Connecting Legs & Wall Flanges of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge.
244Providing and fixing CP brass Pillar Cock with Extension Body of approved brand and quality and conforming to IS 8931 15 mm nominal diameter as per directed by Engineer In Charge.
245Providing and fixing CP brass Angular Stop Cock with Wall Flange of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge.
246Providing and fixing CP brass Shower Arm 240 mm Long Round Shape for Wall Mounted Showers with Wall Flangeof approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge.
247Providing and fixing CP brass Bib Cock with Nozzle of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge.
248Providing and fixing Overhead Shower 125 mm dia Round Shape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System as directed by Engineer In Charge.
249Providing and fixing CP Brass Bottle Trap with Fully Casted Body 32 mm with 190 mm and 125 mm Long Connecting Pipes of approvedquality & make and as per the direction of Engineer-in-charge.
250providing and fixing SS Waste Coupling Half Thread 40mm for Kitchen Sinks/ Wash basin of approved make as directed by Engineer In Charge.
251Providing and fixing CP brass 2-Way Bib Cock with Wall Flange of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge.
252Providing and fixing CP brass Sink Cock with Swinging Spout (Wall Mounted Model) with Wall Flange with wall flange of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge
253Providing and fixing Wall Hung Cistern with 39mm Drainage L-Bend Pipe with Gasket & Installation Kit of approved brand and quality as Directed by Engineer In Charge.
254providing and fixing Hand Shower (Health Faucet) (ABS Body) with 8mm dia, 1 Meter Long Flexible Tube & Wall Hook of approved brand and make as Directed by Engineer In Charge.
255Providing and fixing white vitreous china wall mounted water closet of approved size & shape including seat cover, fittings, nuts, bolts and gasket etc all complete as directed by Engineer In-charge.
256Providing and fixing white vitreous china over the counter wash basin of size 470mm x 360mm x 130mm of approved brand and manufacturer including making all connections as directed by Engineer In Charge.
257Providing and fixing horizontal Chajjah/ Vertical shelves of kota stone in Kitchen Platform/Cupboard shelves 20 to 25 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :
258Providing and fixing PVC SWR grade TYPE B drainage integral rubber ring socketed pipes confirming to IS:13592 including fitiing with required adhesive/rubber lubricant (if/as required) as per manufacturer's specification etc all complete for soil, waste and vent pipes as directed by Engineer In-Charge.Note: 1) Drainage layout shall be prerpared and got approved by Engineer in charge: based on different socket lengths / fittings available of approved make or manufracturer.2) No extra payment will be made for coupler, reducer, Vent cowl with jali or any small fitting in between the drain lines.Only Special fittings like Tee, Bends, Y will be paid separately.
25975mm dia
260110 mm dia
261Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment with Imidacloprid 30.5% SC (including the cost of chemical emulsion) :Note : Dilution with 2.1ml Imidacloprid 30.5% SC with 1 litre of water or as per manufacturer's specification.
262Treatment of existing masonry using chemical emulsion as followsa) Drilling 12 mm dia holes at 45 degree with 75 mm depth at interval of 300 mm apart at wall and floor junction Internal as well as External including staircase, landing area.b) Drilling 6 mm dia holes at downward angle of 45 degree with 50 mm depth at interval of 500 mm apart on wood work of window frame, door frame, cupboard frame and wooden work etc. on both faces.c) Injecting chemical emulsion by hand operated pressure pump at minimum 110-120 ml per hole at interval of 30 minutes i.e (350 ml for each hole complete)d) Plugging them with white cement of matching pigment to the full depth of the hole
263Making circular holes in masonary walls by core cutting of required size for inserting a rigid pvc pipe of 80 mm dia with end cap including finising with cement mortar (1:4 ; cement : fine sand) and making good walls (matching , touching- painting ) etc all complete as directed by engineer in charge.
264providing and fixing Towel rail 600 mm long, CP Brass of approved brand and make as Directed by Engineer In Charge.
265PART B: ELECTRICAL WORK WIRING IN STEEL & PVC CONDUIT
266Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
267Group B
268Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
269Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2702 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2712 X 4 sq. mm + 1 X 4 sq. mm earth wire
2722 X 6 sq. mm + 1 X 6 sq. mm earth wire
273Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
274Group B
275Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2763 x 1.5 sq. mm
2773 x 4 sq. mm
2783 x 6 sq. mm
279Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
28020 mm
28125 mm
282Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
2835/6 A switch
284Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
2851 or 2 Module (75mmX75mm)
2863 Module (100mmX75mm)
2874 Module (125mmX75mm)
2886 Module (200mmX75mm)
289Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
290Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
291Supplying and fixing brass batten/ angle holder including connection etc. as required.
292Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
293Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
294Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
295MCCB, MCB & DB'S
296Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
29712 way , Double door
298Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
299Single pole
300Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
301Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
302EARTHING
303Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
304Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
305Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
306Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
307Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
308Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
309Non-Schedule/MR
310Supplying & Fixing of 300 mm sweep metal body exhaust fan, HEAVY duty,, 230 Volts, 50Hz,1400 RPM single phase A.C.supply andmounting frame on teak wooden frame 19 mm thiknes, complete including making the hole in wall and refinished it with testing,commissioning etc. as reqd. \\"Marathon\\" Make
311LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K /5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3. Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120<135 Im/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA sheet Body (thiness ≥ 0.50 mm) 18-22Watt
312Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection ofsupplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire/copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket, heavy duty end terminal notice connection, danger board, necessary ventilation, earthing strip complete. The Panel shall be painted with epoxy powder coating.(The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size.(A) locally fabricated panel board(1) with 350 mm depth Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57179472
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.84 Crore
LAST DATE 31-08-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Comprehensive External & Internal Repairs And Renovation Works Of Scientist Apartments (One Block Of Total 8 Nos) And External Repairs, Painting, Waterproofing And Termite Treatment Of Scientist Apartments (2 Blocks Having Total 32 Sqs) In Hill Drive Colony Of Csir-Csmcri, Bhavnagar
Basic Detail
Tender No NIT 05/2026-27
Bidding Type Tender
Location
City Bhavnagar
State Gujarat
Key Dates
Publish Date 24 Aug 2026
Submission Date 31 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value 1.84 Crore
Tender Fee 1500
EMD 3.69 Lakhs
Exemption Not Available
Document List
Annexure1to5CSPS.pdf
ba810163-21d4-4da0-9810-6b14eaa4a37a.html
BOQ_336882.xls
TenderbookNIT052627CSPS.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

Annexure1to5CSPS.pdf

html

ba810163-21d4-4da0-9810-6b14eaa4a37a.html

xls

BOQ_336882.xls

pdf

TenderbookNIT052627CSPS.pdf

pdf

Tendernotice_1.pdf

Disclaimer